Plan Review Details - Permit 01120364
Plan Review Stops For Permit 01120364
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-01-22 Cont ID  
Sent By dpalmer Date 2002-01-22 Time 14:02 Rev Time 0.00
Received By dpalmer Date 2002-01-22 Time 14:02 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-12-31 Cont ID  
Sent By dpalmer Date 2001-12-31 Time 06:59 Rev Time 0.00
Received By dpalmer Date 2001-12-31 Time 06:59 Sent To  
Notes
2001-12-31 00:00:00***************** UNSAT**************
  
 1)NOTE: PLEASE NOTE ELECTRICAL PANEL
 "A" SHOWS MCB AND PANEL SCHEDULE SHOW
 MLO?, PLEASE NOTE PANEL"A" IS SHOWN
 COMING FROM METER AND NOT THE 200A RT
 PANEL, PLEASE CORRECT.
  
 2)NOTE: PLEASE CLARIFY MISSING DOOR
 UPSTAIRS BEDROOM?
  
 3)NOTE: PLEASE NOTE A EXTRA SD NEEDS TO
 BE INSTALLED IN HALLWAY UPSTAIRS OR
 MOVE ONE SHOWN AROUND CORNER. NFPA-72
 2-2.1.1.1
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-27 Cont ID  
Sent By hmoser Date 2001-12-27 Time 17:38 Rev Time 0.50
Received By hmoser Date 2001-12-27 Time 17:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-12-21 Cont ID  
Sent By kstevens Date 2001-12-21 Time 21:44 Rev Time 0.50
Received By kstevens Date 2001-12-21 Time 21:44 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-02-06 Cont ID  
Sent By jgomez Date 2002-02-06 Time 12:23 Rev Time 0.50
Received By jgomez Date 2002-02-06 Time 12:23 Sent To  
Notes
2002-02-06 00:00:00TRUSS DRAWINGS REVIEW:
  
 1-ENGINEER OF RECORD TO CLEARLY PROVIDE
 DETAILS AND CONNECTOR SPECIFICATIONS
 THAT RESIST THE UPLIFT LOADS
 CALCULATED ON THE ENGINEERED TRUSSES
 G3, G2 AND G1.
 SEE ENGINEERED TRUSSES FOR CALCULATED
 LOADS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-01-14 Cont ID  
Sent By jgomez Date 2002-01-14 Time 18:25 Rev Time 3.00
Received By jgomez Date 2002-01-14 Time 18:25 Sent To  
Notes
2002-01-14 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE A8. NEED THE ELEVATION
 CERTIFICATE.
 2-RESUBMIT STORM PANELS PRODUCT APPROVAL
 DRAWINGS SUBMITTED ARE VALID FOR ONE
 PERMIT ONLY. SEE NOTE ON DRAWINGS.
 3-PROVIDE UPDATED PRODUCT APPROVAL FOR
 ENTRY DOOR.
 4-REVISE SPECIFICATIONS FOR CEILING
 INSTALLATION AT ENTRY AND REAR PORCH.
 SEE ASTM C926 AND ASTM C1063.
 5-SUBMIT CURRENT PRODUCT APPROVAL FOR
 GARAGE DOOR. PRODUCT APPROVAL
 SUBMITTED WAS DELETED BY SBCCI.
 6-SLIDING GLASS DOORS OPTION WILL NOT
 BE ALLOWED BECAUSE IT WILL EXCEED THE
 MAXIMUM PERCENTAGE OF OPENINGS
 ALLOWED BY TABLE 600 SBC 1997.
 7-CLARIFY SPECIFICATIONS FOR ROOF
 SHEATHING FASTENING. SEE NOTE ON
 STRUCTURAL NOTES AND NOTE ON WALL
 SECTIONS.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-12-11 Cont ID  
Sent By nleiva Date 2001-12-11 Time 07:43 Rev Time 0.25
Received By nleiva Date   Time   Sent To  
Notes
***NONE***