Plan Review Details - Permit 01120356
Plan Review Stops For Permit 01120356
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-12-26 Cont ID  
Sent By dpalmer Date 2001-12-26 Time 14:03 Rev Time 0.00
Received By dpalmer Date 2001-12-26 Time 14:03 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-20 Cont ID  
Sent By hmoser Date 2001-12-20 Time 18:26 Rev Time 0.33
Received By hmoser Date 2001-12-20 Time 18:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-12-21 Cont ID  
Sent By kstevens Date 2001-12-21 Time 20:44 Rev Time 0.50
Received By kstevens Date 2001-12-21 Time 20:44 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-01-17 Cont ID  
Sent By rmcdouga Date 2002-01-17 Time 15:23 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-01-17 00:00:00************BUILDING PROVISO************
  
 1) STRUCTURE IS LOCATED IN AN A8 FLOOD
 ZONE,AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 2) RESUBMIT STORM PANEL INFORMATION WITH
 MASTERED DRAWINGS. THE ONES SUBMITTED
 WERE VALID FOR ONE PERMIT ONLY.
  
 3) PROVIDE UPDATED PRODUCT APPROVALS FOR
 FRONT DOOR.
  
 4) SUBMIT CURRENT PRODUCT APPROVALS FOR
 GARAGE DOOR. SBCCI HAS DELETED THE 2015
 PRODUCT EVALUATION REPORT.
  
 5) REVISE THE EXTERIOR CEILING DETAIL ON
 A-1 & A-1B TO COMPLY WITH ASTM C-1063,
 WHICH REQUIRES FASTENERS TO PENETRATE
 1-3/4" INTO HORIZONTAL FRAMING MEMBERS.
  
 6) MSATER BEDROOM WINDOWS MUST COMPLY
 WITH 97 SBC 1005.4, FOR EMERGENCY
 ESCAPE AND RESCUE OPENINGS.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-12-11 Cont ID  
Sent By nleiva Date 2001-12-11 Time 07:43 Rev Time 0.25
Received By nleiva Date   Time   Sent To  
Notes
***NONE***