Plan Review Details - Permit 01120245
Plan Review Stops For Permit 01120245
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-02-19 Cont ID  
Sent By jgomez Date 2002-02-19 Time 12:21 Rev Time 0.25
Received By jgomez Date 2002-02-19 Time 12:21 Sent To  
Notes
2002-02-19 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-02-05 Cont ID  
Sent By jgomez Date 2002-02-05 Time 19:51 Rev Time 0.25
Received By jgomez Date 2002-02-05 Time 19:51 Sent To  
Notes
2002-02-05 00:00:00PRODUCT APPROVALS SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-01-05 Cont ID  
Sent By jgomez Date 2002-01-05 Time 13:26 Rev Time 1.00
Received By jgomez Date 2002-01-05 Time 13:26 Sent To  
Notes
2002-01-05 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-PROVIDE UPDATED PRODUCT APPROVAL FOR:
 A)STORM SHUTTERS.
 B)SINGLE HUNG WINDOWS.
 C)SLIDING GLASS DOORS.
  
 3-RINKER CERTIFICATION LETTER:
 A)TO BE ADDRESSED TO CITY OF WEST PALM
 BEACH, CONSTRUCTION SERVICES DEPT.
 B)REVISE ADDRESS OF PROJECT. IT IS WEST
 PALM BEACH, NOT ROYAL PALM BEACH.
  
 4-SCREEN ENCLOSURES UNDER SEPARATE
 PERMITS.
  
 NOTES:
 -THESE COMMENTS APPLY TO PERMIT #S:
 01120245, 01120249, 01120254 AND
 01120256.
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01120245.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-12-27 Cont ID  
Sent By btrobaug Date 2001-12-27 Time 16:14 Rev Time 0.30
Received By btrobaug Date 2001-12-27 Time 16:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-12-31 Cont ID  
Sent By mcarsill Date 2001-12-31 Time 08:31 Rev Time 0.00
Received By mcarsill Date 2001-12-31 Time 08:31 Sent To  
Notes
2001-12-31 00:00:001) WET FIRE HYDRANTS REQUIRED PRIOR TO,
 DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REQUIREMENTS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-26 Cont ID  
Sent By hmoser Date 2001-12-26 Time 17:17 Rev Time 0.33
Received By hmoser Date 2001-12-26 Time 17:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-01-04 Cont ID  
Sent By kstevens Date 2002-01-04 Time 10:08 Rev Time 0.33
Received By kstevens Date 2002-01-04 Time 10:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-12-21 Cont ID  
Sent By kstevens Date 2001-12-21 Time 18:52 Rev Time 0.50
Received By kstevens Date 2001-12-21 Time 18:52 Sent To  
Notes
2001-12-21 00:00:00DENIED
 REFERENCE: SPC-94-FHA-AMEND-98
 DESIGN MANUAL
  
 1) SHT A1_MP-1 WATER RISER DIAGRAM, AIR
 CHAMBERS TO HAVE ACCESS PANELS AND SHALL
 BE RECHARGEABLE WITH VALVES AS REQUIRED
 IN SPC SEC 607.8.3. EITHER REMOVE OR
 SHOW DETAILS ON PLANS. (SEE ATTACHED
 SHEET)
  
 2) SHT A_MP-3 PLUMBING NOTES AND SPECS.
 #4. AIR CHAMBERS REQUIRE ACCESS AND MUST
 BE RECHARGEABLE. SEE COMMENT #1. ALSO
 APPROVED WATER HAMMER ARRESTORS DO NOT
 REQUIRE ACCESS AND ARE RECOMMENDED.
  
 3) THIS CONDITION IS TYPICAL OFF ALL
 WATER RISER DIAGRAMS FOR ALL UNITS.
 PLEASE CORRECT AND SHOW DETAILS ON PLANS
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-12-11 Cont ID  
Sent By nleiva Date 2001-12-11 Time 07:48 Rev Time 0.25
Received By nleiva Date   Time   Sent To  
Notes
***NONE***