| Plan Review Stops For Permit 01120245 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-02-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-02-19 |
Time |
12:21 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2002-02-19 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2002-02-19 00:00:00 | TRUSS DRAWINGS REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-02-05 |
Time |
19:51 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2002-02-05 |
Time |
19:51 |
Sent To |
|
|
| Notes |
| 2002-02-05 00:00:00 | PRODUCT APPROVALS SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-01-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-01-05 |
Time |
13:26 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2002-01-05 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2002-01-05 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE AO. NEED THE ELEVATION | | | CERTIFICATE. | | | 2-PROVIDE UPDATED PRODUCT APPROVAL FOR: | | | A)STORM SHUTTERS. | | | B)SINGLE HUNG WINDOWS. | | | C)SLIDING GLASS DOORS. | | | | | | 3-RINKER CERTIFICATION LETTER: | | | A)TO BE ADDRESSED TO CITY OF WEST PALM | | | BEACH, CONSTRUCTION SERVICES DEPT. | | | B)REVISE ADDRESS OF PROJECT. IT IS WEST | | | PALM BEACH, NOT ROYAL PALM BEACH. | | | | | | 4-SCREEN ENCLOSURES UNDER SEPARATE | | | PERMITS. | | | | | | NOTES: | | | -THESE COMMENTS APPLY TO PERMIT #S: | | | 01120245, 01120249, 01120254 AND | | | 01120256. | | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | | PERMIT #01120245. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-12-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2001-12-27 |
Time |
16:14 |
Rev Time |
0.30 |
| Received By |
btrobaug |
Date |
2001-12-27 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-12-31 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-12-31 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-12-31 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2001-12-31 00:00:00 | 1) WET FIRE HYDRANTS REQUIRED PRIOR TO, | | | DURING AND AFTER CONSTRUCTION. | | | 2) BUILDING ADDRESSES REQUIRED. | | | 3) ELECTRIC POWERED SMOKE DETECTORS | | | REQUIRED. | | | 4) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | 5) EGRESS WINDOWS TO COMPLY WITH | | | BUILDING AND FIRE CODE REQUIREMENTS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-12-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-12-26 |
Time |
17:17 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2001-12-26 |
Time |
17:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-01-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-01-04 |
Time |
10:08 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2002-01-04 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-12-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-21 |
Time |
18:52 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-12-21 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2001-12-21 00:00:00 | DENIED | | | REFERENCE: SPC-94-FHA-AMEND-98 | | | DESIGN MANUAL | | | | | | 1) SHT A1_MP-1 WATER RISER DIAGRAM, AIR | | | CHAMBERS TO HAVE ACCESS PANELS AND SHALL | | | BE RECHARGEABLE WITH VALVES AS REQUIRED | | | IN SPC SEC 607.8.3. EITHER REMOVE OR | | | SHOW DETAILS ON PLANS. (SEE ATTACHED | | | SHEET) | | | | | | 2) SHT A_MP-3 PLUMBING NOTES AND SPECS. | | | #4. AIR CHAMBERS REQUIRE ACCESS AND MUST | | | BE RECHARGEABLE. SEE COMMENT #1. ALSO | | | APPROVED WATER HAMMER ARRESTORS DO NOT | | | REQUIRE ACCESS AND ARE RECOMMENDED. | | | | | | 3) THIS CONDITION IS TYPICAL OFF ALL | | | WATER RISER DIAGRAMS FOR ALL UNITS. | | | PLEASE CORRECT AND SHOW DETAILS ON PLANS | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-12-11 |
|
|
Cont ID |
|
| Sent By |
nleiva |
Date |
2001-12-11 |
Time |
07:48 |
Rev Time |
0.25 |
| Received By |
nleiva |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|