| Plan Review Stops For Permit 01120210 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-02-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-02-19 |
Time |
12:20 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2002-02-19 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2002-02-19 00:00:00 | | | | TRUSS DRAWINGS REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-02-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-02-05 |
Time |
19:52 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2002-02-05 |
Time |
19:52 |
Sent To |
|
|
| Notes |
| 2002-02-05 00:00:00 | PRODUCT APPROVALS SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-01-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-01-07 |
Time |
16:01 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2002-01-07 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2002-01-07 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE AO. NEED THE ELEVATION | | | CERTIFICATE. | | | 2-PROVIDE UPDATED PRODUCT APPROVAL FOR: | | | A)STORM SHUTTERS. | | | B)SINGLE HUNG WINDOWS. | | | C)SLIDING GLASS DOORS. | | | | | | 3-RINKER CERTIFICATION LETTER: | | | A)TO BE ADDRESSED TO THE CITY OF WEST | | | PALM BEACH, CONSTRUCTION SERVICES DEPT | | | B)REVISE ADDRESS OF PROJECT. IT IS WEST | | | PALM BEACH, NOT ROYAL PALM BEACH. | | | | | | 4-SCREEN ENCLOSURES UNDER SEPARATE | | | PERMITS. | | | | | | | | | | | | NOTES: | | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | | PERMIT # 01120210. | | | -THESE COMMENTS APPLY TO PERMIT #S: | | | 01120210, 01120225, 01120230 AND | | | 01120232. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-01-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-01-05 |
Time |
17:03 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2002-01-05 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2002-01-05 00:00:00 | CHECKLIST: | | | 1-MODEL BR ON LOT 125 DOESN'T COMPLY | | | WITH TABLE 600 SBC 1997 WHEN HAVING | | | THE OPTION OF 6080 SLIDING GLASS DOOR. | | | DELETE THIS OPTION. ALL MODELS THAT | | | HAVE THIS OPTION WILL NOT COMPLY WITH | | | TABLE 600 SBC 1997. | | | 2-PROVIDE UPDATED PRODUCT APPROVAL FOR: | | | A)STORM PANELS. | | | B)SINGLE HUNG WINDOWS. | | | C)SLIDING GLASS DOORS. | | | | | | 3-RINKER CERTIFICATION LETTER: | | | A)TO BE ADDRESSED TO THE CITY OF WEST | | | PALM BEACH, CONSTRUCTION SERVICES DEPT | | | B)REVISE ADDRESS OF PROJECT AS REQUIRED. | | | | | | | | | | | | | | | | | | | | | | | | NOTES: | | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | | PERMIT #01120210. | | | -THESE COMMENTS APPLY TO PERMIT #S: | | | 01120210, 01120225, 01120230 AND | | | 01120232. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-12-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2001-12-28 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2001-12-28 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-12-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-12-28 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-12-28 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2001-12-28 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO,DURING AND AFTER CONSTRUCTION. | | | 2) BUILDING ADDRESSES REQUIRED. | | | 3) ELECTRIC POWERED SMOKE DETECTORS | | | REQUIRED. | | | 4) EGRESS WINDOWS TO COMPLY WITH | | | BUILDING AND FIRE CODE REQUIREMENTS. | | | 5) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-12-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-12-26 |
Time |
18:34 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2001-12-26 |
Time |
18:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-01-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-01-03 |
Time |
16:48 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2002-01-03 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-12-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-21 |
Time |
19:56 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-12-21 |
Time |
19:56 |
Sent To |
|
|
| Notes |
| 2001-12-21 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FHA-AMEND-98 DESIGN | | | MANUAL | | | | | | 1) SHTS BR_MP-1, A1_MP-1, B_MP-1 & A3_ | | | MP-1. WATER RISER DIAGRAMS, AIR CHAMBERS | | | TO HAVE ACCESS PANELS AND SHALL BE RE- | | | CHARGEABLE WITH VALVES AS REQUIRED IN | | | SPC SEC 607.8.3 AND PDI-WH 201. EITHER | | | REMOVE OR SHOW DETAILS ON PLANS FOR | | | ACCESS AND HOW THEY WILL BE RECHARGED. | | | (SEE ATTACHED SHEET) | | | | | | 2) SHT BR_MP-4, A_MP-3, & B_MP-4, PLUMB- | | | ING NOTES AND SPECS #4. AIR CHAMBERS RE- | | | QUIRE ACCESS AND MUST BE RECHARGEABLE. | | | (SEE COMMENT #1) ALSO APPROVED WATER | | | HAMMER ARRESTORS DO NOT REQUIRE ACCESS | | | AND ARE RECOMMENDED. | | | | | | 3) THIS CONDITION IS TYPICAL OF ALL | | | WATER RISER DIAGRAMS IN ALL UNITS. | | | PLEASE CORRECT ON PLANS AND SHOW DETAILS | | | | | | REVIEW BY KEN STEVENS | | | (561) 569-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-12-11 |
|
|
Cont ID |
|
| Sent By |
nleiva |
Date |
2001-12-11 |
Time |
07:47 |
Rev Time |
0.25 |
| Received By |
nleiva |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|