Plan Review Details - Permit 01120136
Plan Review Stops For Permit 01120136
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-06-17 Cont ID  
Sent By jwitmer Date 2002-06-17 Time 15:01 Rev Time 0.75
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-03-21 Cont ID  
Sent By jwitmer Date 2002-03-21 Time 14:13 Rev Time 1.50
Received By jwitmer Date 2002-03-21 Time 14:13 Sent To  
Notes
2002-03-21 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01120136
 820 RIDGEWOOD DR
 CONT: GARRETT CONST CORP
 TEL: 792-6090
 THIRD REVIEW
  
 SBC= 1997 STANDARD BUILDING CODE
  
 FLORIDA STATE STATUTE 553.80.2(B) THE
 LOCAL GOVERNMENT SHALL IMPOSE, EACH TIME
 AFTER THE THIRD SUCH REVIEW THE PLANS
 ARE REJECTED FOR THE SAME VIOLATION, A
 FEE OF FOUR TIMES THE AMOUNT OF THE
 PROPORTION OF THE PERMIT FEE ATTRIBUTED
 TO PLAN REVIEW.
  
 1)- ROOF ASSEMBLY: THE PRODUCT APPROVAL
 SUBMITTED FOR THE "MASTER RIB" METAL
 ROOFING IS EXPIRED. ONLY THE TOP PAGE
 WAS SUBMITTED.THE CITY SEARCHED THE
 METRO-DADE PRODUCT APPROVAL SITE USING
 ADVANCED SEARCH THROUGH ROOFING AS WELL
 AS PANELS AND DIDNOT FIND ANY CURRENT RE
 PORT FOR THE COMPANY UNION CORRUGATED
 COMPANY, A SEARCH FOR ACCEPTANCE NO.
 98-04211. ALSO HAD NO RESULTS.
 THE PRODUCT TESTING REPORT SHALL INDI-
 CATE IF THE STEEL ROOFING IS TESTED AS
 STRUCTURAL PANELS WHICH WOULD NOT
 REQUIRE SOLID SHEATHING BENEATH OR WILL
 INDICATE A NON-STRUCTURAL PANEL REQUIR-
 ING SOLID SHEATHING. A MANUFACTURERS
 SPEC SHALL ALSO BE REQUIRED FOR THE
 ATTACHMENT METHOD.
 SEE SBC1509 & 1510 FOR STEEL ROOFING
 REQUIREMENTS.
  
 2)- CONTRACTOR SHALL SUBMIT PLANS TO THE
 COUNTY FOR IMPACT FEE ASSESSMENT.
  
 3)- PAY RADON FEES OF $8.64.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096X8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-02-05 Cont ID  
Sent By jwitmer Date 2002-02-05 Time 09:35 Rev Time 1.00
Received By jwitmer Date 2002-02-05 Time 09:35 Sent To  
Notes
2002-02-05 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01120136
 820 RIDGEWOOD DR
 CONT: GARRETT CONST CORP
 TEL: 792-6090
 SECOND REVIEW
  
 SBC= 1997 STANDARD BUILDING CODE
  
 1)- SBC 2304.2.2 ALL POST POLES &
 COLUMNS SUPPORTING PERMANENT STRUCTURES
 AND EMBEDDED IN CONCRETE WHICH IS IN
 CONTACT WITH GROUND SHALL BE APPROVED
 PRESERVATIVE-TREATED WOOD SUITABLE FOR
 GROUND CONTACT USE.
  
 2) SBC 1606.2.6.2 COMPONENTS & CLADDING
 PRODUCT APPROVALS (2 COPIES) SHALL BE RE
 QUIRED FOR THE FOLLOWING ITEMS:
  
 GARAGE OR OVERHEAD DOORS: OPENING SIZE
 IS 10'WX 8'H THE REPORT FURNISHED IS
 MAX AT 9'WX 8H'.
 ROOF ASSEMBLY TOP SHEET OF REPORT NOT
 ACCEPTABLE, REPORT IS EXPIRED.
 REPORT SHALL INDICATE IF THE METAL
 PANEL ROOFING IS ARCHITECTURAL
 METAL REQUIRING SOLID SHEATHING OR
 SBC 1509 OR STRUCTURAL METAL ROOFING
 COVERED IN SBC 1510 WHICH WILL ALLOW
 ATTACHMENT THROUGH PURLIN SYSTEM.
 IF REPORT DOESN'T INDICATE FREQUENCY
 OF ATTACHMENT MANUFACTURES SPEC
 SHALL BE REQUIRED.
  
 3)- CONTRACTOR TO SUBMIT PLANS TO COUNTY
 FOR IMPACT FEE ASSESMENT.
  
 4) PAY RADON FEES, $8.64.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-12-11 Cont ID  
Sent By jwitmer Date 2001-12-11 Time 07:15 Rev Time 2.50
Received By jwitmer Date 2001-12-11 Time 07:15 Sent To  
Notes
2001-12-11 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01120136
 820 RIDGEWOOD DR.
 CONT: GARRETT CONST. CORP.
 TEL: 792-6090
  
 SBC= STAANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
  
 DESIGN CERTIFCATION SHEET
 1)- OCCUPANCY: PLANS INDICATE S.F.R.
 CAT. IV.ASCE7-95 TABLE 1-1 MINOR
 STORAGE FACILITY TYPE I NOT IV
  
 2)- BUILDING PARTIALLY ENCLOSED? PLANS
 INDICATE TOTALLY ENCLOSED.
  
 3)- DESIGN FOR 7-95 IS 145 WIND ZONE.
  
 4)- IMPORTANCE FACTOR INCORRECT ASCE
 7.95 TABLE 0.87
  
 5)- ASCE 7-95 EXPOSURE NOT GIVEN, 6.5.3.
 3.1 EXPOSURE CATORIES
  
 6)- SBC 2304.2.2 ALL POST POLES & COL-
 UMNS SUPPORTING PERMANENT STRUCTURES AND
 EMBEDDED IN CONCRETE WHICH IS IN CONTACT
 WITH GROUND SHALL BE APPROVED PRESERVA-
 TIVE-TREATED WOOD SUITABLE FOR GROUND
 CONTACT USE.
  
 7)- SBC 1606.2.6.2 COMPONENTS & CLADDING
 PRODUCT APPROVALS (2 COPIES) SHALL BE
 REQUIRED FORTHE FOLLOWING ITEMS:
 GARAGE OR OVERHEAD DOORS
 EXTERIOR SWING DOORS
 ROOFING ASSEMBLIES
 SBCCI OR DADE COUNTY TEST REPORTS
 ARE REQUIRED.
  
 8)- SBC 1510 STRUCTURAL METAL ROOFING
 SUPPLY MANUFACTURES SPECS FOR APPLCATION
 ALSO SUPPLY INFOR THAT THE ROOF IS
 CAPABLE OF RESISTING LIVE LOADS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-03-21 Cont ID  
Sent By dpalmer Date 2002-03-21 Time 10:03 Rev Time 0.00
Received By dpalmer Date 2002-03-21 Time 08:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-01-30 Cont ID  
Sent By dpalmer Date 2002-01-30 Time 15:18 Rev Time 0.00
Received By dpalmer Date 2002-01-30 Time 15:14 Sent To  
Notes
2002-01-30 00:00:00************* UNSAT *******************
  
 1)NOTE: PLEASE NOTE THAT PLANS ARE NOW
 BEING SHOWN DELETING ELECTRICAL SERVICE
 AND ELECTRICAL INSIDE GARAGE?
 PLEASE NOTE THAT PER NEC A LIGHT AND
 RECEPT IS REQ`D. THEY BOTH CAN BE ON
 ONE CIRCUIT, BUT MUST CONTAIN A MEANS
 OF DISCONNECT AT DETACHED BLDG.
 225-31
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-12-11 Cont ID  
Sent By dpalmer Date 2001-12-11 Time 19:19 Rev Time 0.00
Received By dpalmer Date 2001-12-11 Time 19:19 Sent To Z
Notes
2001-12-11 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT PER ZONING REG
 A SEPARATE SERVICE IS NOT PERMITTED FOR
 ZONING OF SF-7(SINGLE FAMLIY) PLEASE
 NOTE THAT ELECTRICAL FOR DETACHED GARAGE
 WOULD NEED TO COME FROM EXISTING ELEC
 SERVICE OR FROM NEW SERVICE MOUNTED ON
 GARAGE AND BY BACK FEEDING EXISTING
 HOUSE.
  
 2)NOTE: PLEASE NOTE THAT ALL OUTLETS IN
 GARAGE NEED TO BE SHOWN AS GFI/GFI
 PROTECTED PER210-8.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-06-18 Cont ID  
Sent By rmcdouga Date 2002-06-18 Time 13:47 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-06-18 Cont ID  
Sent By rmcdouga Date 2002-06-18 Time 13:48 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-12-10 Cont ID  
Sent By dpalmer Date 2001-12-11 Time 19:24 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***