Plan Review Details - Permit 01120102
| Plan Review Stops For Permit 01120102 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-01-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-01-03 |
Time |
09:45 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-12-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-02 |
Time |
12:30 |
Rev Time |
1.75 |
| Received By |
dpalmer |
Date |
2001-12-21 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2001-12-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01120102 | | | 1001 SUMMIT BLVD | | | O/B SALGADO, BERNARDO | | | TEL: 547-3893 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | SBC*= AMENDMENTS STANDARD BUILDING CODE | | | | | | 1)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | NEW WINDOWS WILL REQUIRE PRODUCT TESTING | | | REPORTS FOR LARGE MISSLE IMPACT RESIS- | | | TAANCE TESTING. 2 COPIES EITHER SBCCI OR | | | DADE COUNTY PRODUCT TESTING REPORTS ARE | | | ACCEPTED. | | | | | | 2)- THE GUEST BEDROOM SHALL REQUIRE A | | | SECOND MEANS OF EGRESS( SBC 1005.4.4) | | | INDICATE THE SIZE OF THE WINDOW, WHAT | | | WILL THE NET CLEAR AREA OF THE OPENING | | | BE WHEN WINDOW IS OPEN? | | | | | | 3)- SBC 2309.6 ACCESS TO ATTIC SPACE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-06-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-06-14 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-06-14 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-01-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-02 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-01-02 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2002-01-02 00:00:00 | ****************** UNSAT ************* | | | | | | 1)NOTE: PLEAS ENOTE THAT NO INFORMATION | | | WAS SUBMITTED FOR EXISTING SERVICE SIZE? | | | PLEASE SHOW SIZE OF EXISITNG, METERCAN | | | AND WIRE SERVICE ENTRANCE CONDUCTORS | | | NEW LOAD IS SHOWN AT 57AMPS., PLEASE | | | CLARIFY LOAD FOR MAIN HOUSE. | | | MAIN HOUSE EXISTING SERVICE WAS 150A. | | | | | | 2)NOTE: PLEASE NOTE THAT NO MEANS OF | | | DISCONNECT IS SHOWN FOR | | | DETACHED BLDG. 225-31. PLEASE NOTE 125A | | | PANEL IS SHOWN AS MLO? | | | | | | 3)NOTE: PLEASE NOTE EXISTING GROUNDING | | | ELECTRODE SYSTEM IS SHOWN FOR MAIN HOUSE | | | BUT NOT FOR DETACHED BLDG? PLEASE | | | CLARIFY. | | | | | | PLEASE SUBMIT THE ABOVE INFOAMTION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-10 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-10 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2001-12-10 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE CLARFIY TWO SMALL APPLI- | | | ANCE CIRCUITS SHOWN. AS PER ZOING REQ`- | | | -MENTS, KITCHEN NOT PERMITTED. | | | | | | 2)NOTE: PLEASE CLARIFY SIZE OF EXISTING | | | SERVICE ENTRANCE CONDCUTORS. | | | NEW LOADS BEING ADDED NEED CLARIFICATION | | | | | | 3)NOTE: PLEASE NOTE PLANS SHOW TWO NEW | | | MAIN DISC`S ? PLEASE SUBMIT AIC RATINGS | | | FOR ALL NEW EQUIPMENT PER 110-9. | | | | | | 4)NOTE: PLEASE SHOW LOAD ON EXSITING | | | HOUSE NEEDED FOR CLARIFICATION OF | | | EXISTING SERVICE ENTRANCE CONDUCTORS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2002-01-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-02 |
Time |
12:27 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-01-02 |
Time |
12:15 |
Sent To |
B |
|
| Notes |
| 2002-01-02 00:00:00 | | | | | | | NOTE ON RESUB INDICATES MECHANICAL | | | CONTRACTOR TO ADDRESS COMMENTS FROM 1ST | | | REVIEW.(SUPPLY ENERGY CALCS & MANUAL | | | J) |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-12-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-18 |
Time |
14:50 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-12-18 |
Time |
14:48 |
Sent To |
B |
|
| Notes |
| 2001-12-18 00:00:00 | *******************DENIED*************** | | | | | | AN HVAC SIZING CALCULATION SHALL BE | | | PERFORMED ON THE BUILDING AND SHALL BE | | | ATTACHED TO THE FORM 600 SUBMITTED WHEN | | | APPLICATION IS MADE.SIZING OF THE | | | HVAC SYSTEM SHALL BE DETERMINED FOR | | | EACH ZONE WITHIN A DWELLING IN | | | ACCORDANCE WITH ACCA MANUAL J. | | | | | | PLEASE PROVIDE THE ABOVE INFORMATION FOR | | | REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-12-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-15 |
Time |
13:58 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-12-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-12-05 |
Time |
10:45 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|