Plan Review Details - Permit 01120092
| Plan Review Stops For Permit 01120092 |
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2002-01-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2002-01-07 |
Time |
10:01 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-01-07 00:00:00 | DENIED, BLDGDOES NOT MEET SET BACK. PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-12-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-18 |
Time |
12:12 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2001-12-18 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2001-12-18 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) OPENING FOR WATER CLOSET, LAV. AND | | | SHOWER SHALL BE MINIMUM OF 95" ROUGH | | | OPENING. 15" OFF FINISHED WALL TO CENTER | | | LINE OF W/C, 30" CENTER OF W/C TO C/L OF | | | LAV, LAV TO BE MINIMUM OF 4" OFF SHOWER | | | WALL, AND SHOWER TO MINIMUM OF 30" IN- | | | SIDE FINISHED SIDE TO SIDE. | | | SPC SEC 403.4 - SEC 417.4 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-12-16 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-16 |
Time |
10:25 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-16 00:00:00 | PLUMBING PLAN REVIEW DENIED. | | | MIN FACILITIES REQ. LAV IN BATH RM. | | | SHOW ALL EX FACILITIES INC WASHING | | | MACHINE LOCATION. | | | END OF COMMENTS PAUL SCHMITZ | | | 659-8096X8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-12-04 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2001-12-04 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) DRY VENT NOT ACCEPTABLE PER SPC SEC | | | 906.2.1. | | | | | | 2) MINIMUM 3" VENT REQUIRED FOR EACH | | | SEPARATE BLDG DRAIN. SPC SEC 904.3.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
|