Plan Review Details - Permit 01120053
| Plan Review Stops For Permit 01120053 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-01-07 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-01-07 |
Time |
08:06 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-01-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-04 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-01-04 |
Time |
10:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-01-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-02 |
Time |
06:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-01-02 |
Time |
06:19 |
Sent To |
P |
|
| Notes |
| 2002-01-02 00:00:00 | ******************* UNSAT ************ | | | | | | 1)NOTE: PLEASE NOTE THAT NOW HEAT PUMP | | | SPEC AND LOAD CALCUALTIONS WERE SUBMITT- | | | -ED BUT WIRING DIAGRAM STILL DOESN'T | | | REFLECT ANY ASSC WIRING. | | | PLEASE NOTE HEAT PUMP AND WIRING/CONDUIT | | | AND WIRE SIZES MUST BE SHOWN ON PLANS. | | | PLEASE ALOS NOTE THAT ALL CHANGES MUST | | | BE DONE BY THE ENGINEER OF RECORD. | | | FS/FAC 471.025. | | | | | | 2)NOTE: PLEASE CLARIFY SERVICE, LOAD | | | CALCS SHOW TWO 100A PANELS? PLEASE | | | CLARIFY HOW THESE TWO PANELS ARE GETTING | | | THEIR FEEDS? ARE THEY COMING FROM A 200A | | | METERCAN AND SERVICE? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANYQUESTIONS, | | | PLEASE CALL. | | | | | | DEWEYPALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-12-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-19 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-19 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2001-12-19 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE CLARIFY, APPLICATION | | | SHOWS HEAT PUMP? PLEASE NOTE THAT NO | | | SPECS WERE SUBMITTED AND NOT ON WIRING | | | DIAGRAM? | | | PLEASE CLARIFY. | | | | | | PLEASE SUBMIT THEABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-01-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-01-05 |
Time |
06:58 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2002-01-05 |
Time |
06:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-04 |
Time |
10:42 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-12-05 |
Time |
21:35 |
Sent To |
|
|
| Notes |
| 2001-12-05 00:00:00 | DENIED | | | REFERENCE: SPC-94 - UNIFORM COUNTYWIDE | | | SWIMMING POOL AND SPA | | | CODE. | | | | | | 1) UCSPS CODE SEC 36(E) MINIMUM 3 | | | RETURNS REQUIRED. 2 SHOWN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-12-10 |
Time |
11:00 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|