| 2001-12-20 00:00:00 | AN OWNER BUILDER PERMIT MAY ONLY BE |
| | ISSUED TO THE OWNER OF THE PROPERTY. |
| | ALTERNATIVELY, ONLY A LICENSED |
| | CONTRACTOR MAY OBTAIN A PERMIT.SEE |
| | THE ATTACHED EXCERPT FROM FS 468. |
| | |
| | THE GABLE END WALL AT THE NORTH SIDE IS |
| | REQUIRED BY SBC TABLE 600 TO BE ONE |
| | HOURFIRE RATED.SEE ALSO FOOTNOTE "I" |
| | TO TABLE 600 REGARDING TEST |
| | REQUIREMENTS. |
| | |
| | SBC 1012.1.6 REQUIRES A LANDING AT THE |
| | FRENCH DOORS. |
| | |
| | SHEET A3 SECTION AT THE WEST WALL, SHOWS |
| | WOOD STAIRS WITH A RISE TO RUN RATIO |
| | THAT DOES NOT COMPLY WITH SBC 1007.3.1. |
| | ALSO, SHEET A2 SHOWS MASONRY STAIRS. |
| | PLEASE REVISE AS NECESSARY. |
| | |
| | SBC 2309.6 REQUIRES THE ATTIC ACCESS TO |
| | BE A MINIMUM OF 22" X 36". |
| | |
| | SBC 2405.2.1 (2) REQUIRES SAFETY GLAZING |
| | IN THE WINDOW NEAR THE BATHTUB. |
| | |
| | BEFORE A PERMIT TO CONSTRUCT CAN BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY FOR THE CITY, THE |
| | PERMIT PLANSSTAMPED BY THAT OFFICE AND |
| | A COPY OF THEPAID RECEIPT ATTACHED TO |
| | THE PERMIT APPLICATION.CALL 233-5025 |
| | FOR MORE INFORMATION. |
| | |
| | THE NOTICE OF ACCEPTANCE REPORT FOR THE |
| | WINDOWS, 98-0218.02, IS EXPIRED. |