Plan Review Details - Permit 01111098
Plan Review Stops For Permit 01111098
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-15 Cont ID  
Sent By jwitmer Date 2002-01-15 Time 14:55 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-12-10 Cont ID  
Sent By pkrauss Date 2002-01-12 Time 10:44 Rev Time 0.50
Received By jwitmer Date 2001-12-10 Time 12:21 Sent To  
Notes
2001-12-10 00:00:00BUILDING PLAN DREVIEW
 PERMIT # 01111098
 2611 MOHAWK CI
 CONT CREATIVE CONST CORP
 TEL: 691-9257
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
  
 1)- SITE PLAN REQUIRED FOR TABLE 600
 ISSUES.
  
 2)- SBC 1606.2.6.2COMPONENTS & CLADDING
 WINDOW & DOOR BUCK ATTACHMENT.
  
 3)- SBC 1606.4.1/ 1707.4.1* CITY
 REQUIRES 2 COPIES OF PRODUCT APPROVAL
 FOR GLAZED OPENINGS, W/ LARGE MISSLE
 IMPACT TESTING. SBCCI OR DADE COUNTY
 REPORTS ARE ACCEPTED.
  
 4)- ROOF COVERINGS:SBC 1503.3.2.
 ROOFING IS TO BE TESTED FOR 110 MPH
 WIND ZONE.
  
 5)-PLANS ARE TO BE SUMMITTED TO PALM
 BEACH COUNTY FOR ASSESMENT, IMPACT FEES.
  
 6)- RADON FEES $3.52

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-12-05 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 20:15 Rev Time 0.00
Received By dpalmer Date 2001-12-05 Time 20:15 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-01-12 Cont ID  
Sent By pkrauss Date 2002-01-12 Time 10:41 Rev Time 0.35
Received By pkrauss Date 2002-01-12 Time 10:41 Sent To B
Notes
2002-01-12 00:00:00 
 MECHANICAL PERMIT REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-12-07 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 20:16 Rev Time 0.40
Received By pkrauss Date 2001-12-07 Time 10:24 Sent To P
Notes
2001-12-07 00:00:00 
  
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR REVIEW WITH MECHANICAL PERMIT
 APPLICATION.
  
 1.MAKE, MODEL, BTU, KW HEAT STRIP
 FOR THE AHU AND SEER OF CONDENSER.
 (NEW EQUIPMENT)
  
 2.PROVIDE SIZE, MATERIAL, DUCT LAYOUT,
 AND CFM DISTRIBUTION.
  
 3.PROVIDE ENERGY AND MANUAL J
 CALCULATIONS.
  
 4.INDICATE LOCATION OF CONDENSER
 UNIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status N Date 2001-12-08 Cont ID  
Sent By pkrauss Date 2001-12-07 Time 10:33 Rev Time 0.33
Received By kstevens Date 2001-12-08 Time 07:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-30 Cont ID  
Sent By sgraham Date 2001-11-30 Time 14:54 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***