Plan Review Details - Permit 01110998
Plan Review Stops For Permit 01110998
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-12-10 Cont ID  
Sent By hpiskura Date 2001-12-10 Time 07:48 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-12-10 00:00:00PLANS ARE APPROVED WITH THE PROVISION
 THAT THE EGRESS DOORS EQUIPPED WITH
 CARD READERS OR OTHER LOCKING DEVICES
 ARE CONFIGURED IN ACCORDANCE WITH
 THE REQUIREMENTS OF SBC
 1012.7 FOR ACCESS CONTROLLED EGRESS
 DOORS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-07-16 Cont ID  
Sent By dpalmer Date 2002-07-16 Time 12:50 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-12-05 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 21:27 Rev Time 0.00
Received By dpalmer Date 2001-12-05 Time 21:27 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-12-10 Cont ID  
Sent By hpiskura Date 2001-12-10 Time 07:59 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-05-24 Cont ID  
Sent By mcarsill Date 2002-05-24 Time 09:42 Rev Time 0.00
Received By mcarsill Date 2002-05-24 Time 09:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-11-29 Cont ID  
Sent By mcarsill Date 2001-11-29 Time 11:32 Rev Time 0.00
Received By mcarsill Date 2001-11-29 Time 11:32 Sent To  
Notes
2001-11-29 00:00:001) NO INTERIOR FINISH CALSSIFICATION
 INFORMATION FOR WALLS AND CEILINGS.
 2) CARD READERS NOTED ON DOORS USED FOR
 EXITING. PLEASE EXPLAIN. DOORS USED FOR
 EXITING THAT POSSESS ANY LOCKING OR
 SECURITY DEVICES MUST COMPLY WITH
 "SPECIAL LOCKING ARRANGEMENTS" OF THE
 LIFE CODE. IS EGRESS POSSIBLE FROM THE
 TENANT SIDE REGARDLESS OF THE USE OF A
 CARD. FREE EGRESS OR FAIL SAFE, OR ARE
 THE DOORS FAIL SECURE. PLEASE PROVIDE
 MORE INFORMATION.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-05-25 Cont ID  
Sent By hmoser Date 2002-05-25 Time 07:42 Rev Time 0.50
Received By hmoser Date 2002-05-25 Time 07:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-12-10 Cont ID  
Sent By pkrauss Date 2001-12-10 Time 10:22 Rev Time 0.50
Received By pkrauss Date 2001-12-10 Time 10:01 Sent To  
Notes
2001-12-10 00:00:00******************DENIED****************
  
  
 PLAN SHEET M-1.1 NOTE 2, EXHAUST FOR BLU
 E PRINT ROOM TO BE SCH 40 PVC.THIS IS
 PROHIBITED IN A RETURN AIR PLENUM AS PER
 1997 SMC 609.1.1.
  
 1.PROVIDE OUTSIDE AIR CALCULATIONS
 AS PER ASHRAE 62-89.
  
 2.PLEASE PROVIDE AIR BALANCE SCHEDULE
 SHOWING COMPLIANCE WITH 1997 SMC
 501.2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388

Review Stop Z ZONING
Rev No 1 Status N Date 2001-12-10 Cont ID  
Sent By hpiskura Date 2001-12-10 Time 07:59 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***