Plan Review Details - Permit 01110976
Plan Review Stops For Permit 01110976
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-07 Cont ID  
Sent By pkrauss Date 2002-01-08 Time 11:16 Rev Time 0.00
Received By rbrown Date 2002-01-07 Time 11:15 Sent To  
Notes
2002-01-07 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE
 SBC*= STANDARD BUILD'G CODE (AMENDMENTS)
  
 --PROVISO--
 SBC* 104.1.1A SEPARATE PERMIT
 APPLICATION IS REQUIRED FOR THE ALUMINUM
 SHUTTERS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-12-19 Cont ID  
Sent By rbrown Date 2001-12-19 Time 17:04 Rev Time 0.00
Received By rbrown Date 2001-12-19 Time 17:03 Sent To  
Notes
2001-12-19 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE
 SBC*= STANDARD BUILD'G CODE (AMENDMENTS)
 FL ENERGY CODE = FLORIDA ENERGY
 EFFICIENCY CODE FOR BUILD'G CONSTR'N
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SBC* 104.1.1A PRODUCT APPROVAL IS
 REQUIRED FOR THE ELECTRICAL ROLL DOWN
 SHUTTERS.
  
 4) SBC 1503.1.2.3THE ROOF SLOPE SHALL
 BE MINIMUM 1/4" PER FOOT.
  
 5) SBC 2308.2.2.1THE PLYWOOD WALL
 SHEATHING SHALL BE MINIMUM 5/8" THICK.
  
 6) SBC 2306.2THE WOOD HEADER DETAIL
 REFERS TO A SIMPSON MSTA16 CONNECTOR
 BETWEEN THE HEADER AND JACK STUD.THIS
 IS NOT A VALID SIMPSON REFERENCE.
 PROVIDE PRODUCT DETAILS OR A CORRECT
 REFERENCE.
  
 7) FL ENERGY CODE 103.0COMPLIANCE WITH
 THE CODE SHALL BE DEMONSTRATED THROUGH
 SUBMITTAL OF CODE COMPLIANCE FORMS.
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-12-05 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 17:46 Rev Time 0.00
Received By dpalmer Date 2001-12-05 Time 17:46 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-01-08 Cont ID  
Sent By pkrauss Date 2002-01-08 Time 09:32 Rev Time 0.40
Received By pkrauss Date 2002-01-08 Time 09:32 Sent To B
Notes
2002-01-08 00:00:00 
 MECHANICAL PERMIT 01110977.
  
 ADDING DUCT AND 2 DROPS FROM EXISTING 5
 TON SYSTEM TO ADDITION.ALSO EXISTING 3
 TON SYSTEM NO ADDITIONS OR CHANGES TO
 THIS SYSTEM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-12-07 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 17:47 Rev Time 0.35
Received By pkrauss Date 2001-12-07 Time 07:21 Sent To P
Notes
2001-12-07 00:00:00******************DENIED****************
  
 MECHANICAL PERMIT 01110977
  
  
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR REVIEW:
  
 1.ENERGY CALCULATIONS WITH MANUAL J.
  
 2.PROVIDE EXISTING EQUIPMENT DATA.
 MAKE, MODEL, BTU'S, KW OF HEAT
 STRIP, SEER OF CONDENSER.
  
 3.INDICATE SIZE, MATERIAL, LAYOUT
 AND CFM DISTRIBUTION OF NEW DUCT
 WORK BEING INSTALLED.
  
 4.PROVIDE SQUARE FOOTAGE OF EXISTING
 HOUSE AS WELL AS THE ADDITION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status N Date 2001-12-07 Cont ID  
Sent By pkrauss Date 2001-12-07 Time 07:34 Rev Time 0.00
Received By kstevens Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-29 Cont ID  
Sent By sgraham Date 2001-11-29 Time 15:06 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***