Plan Review Details - Permit 01110795
Plan Review Stops For Permit 01110795
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-12-10 Cont ID  
Sent By dpalmer Date 2001-12-10 Time 19:58 Rev Time 0.00
Received By dpalmer Date 2001-12-10 Time 19:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-10 Cont ID  
Sent By hmoser Date 2001-12-10 Time 17:42 Rev Time 0.33
Received By hmoser Date 2001-12-10 Time 17:42 Sent To  
Notes
2001-12-10 00:00:00NO MECHANICAL PERMIT NUMBER ON THIS
 APPLICATION12/10/01 H.M.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-12-07 Cont ID  
Sent By kstevens Date 2001-12-07 Time 15:45 Rev Time 0.33
Received By kstevens Date 2001-12-07 Time 15:45 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-04-16 Cont ID  
Sent By rmcdouga Date 2002-04-16 Time 11:23 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-04-16 00:00:00LOT CHANGE DENIED REAR ELEVATION DOES
 NOT COMPLY WITH 97 SBC TABLE 600 FOR
 PERCENTAGE OF WALL AREA ALLOWED AS
 OPENINGS, A REVISION WILL BE NECESSARY.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-01-23 Cont ID  
Sent By rmcdouga Date 2002-01-23 Time 09:08 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-01-23 00:00:00************BUILDING PROVISO************
  
 1) STRUCTURE IS LOCATED IN AN A-8 FLOOD
 ZONE, AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 2) SUBMIT CURRENT PRODUCT APPROVALS FOR
 GARAGE DOOR. SBCCI HAS DELETED THE 2015
 REPORT FOR ABLE GARAGE DOORS.
  
 3) RESUBMIT STORM PANEL INFORMATION WITH
 MASTERED DRAWINGS. THE ONES THAT WERE
 SUBMITTED WERE VALID FOR ONE PERMIT ONLY
  
 4) PROVIDE PRODUCT APPROVALS FOR ONE
 HOUR RATED GLASS BLOCK.
  
 5) PROVIDE UPDATED PRODUCT APPROVALS FOR
 FRONT DOOR.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-12-20 Cont ID  
Sent By rmcdouga Date 2001-12-20 Time 11:52 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-12-20 00:00:00*************BUILDING UNSAT*************
  
 1) THE PRIVACY WALL DETAIL (F-13) ON A-1
 INDICATES FILLED CELLS W/ VERTICLE
 REINFORCEMENT AT 24" O.C. AND THE PLAN
 SHOWS 8"X16" BLOCK W/2 #5 VERTICLE BARS
 SPACED 5' O.C. PLEASE CORRECT.
  
 2) THE WALL SECTION ON A-2 INDICATES A
 20" DEEP FOOTER AND THE FOOTER SCHEDULE
 ON A-1 HAS THE FOOTER DEPTH OF 18".
 PLEASE CORRECT.
  
 3) THE ROOF NOTES ON THE WALL SECTION ON
 A-2 SPECIFIES THE SHEATHING NAILED 4"
 O.C. THRU-OUT THE ENTIRE ROOF AND THE
 STRUCTURAL NOTES ON A-4 CALL FOR THE
 ROOF SHEATHING TO BE NAILED 4" ON THE
 EDGES AND 6" IN THE FIELD. PLEASE
 CORRECT.
  
 4) THE DOOR FROM THE GARAGE TO THE
 CONDITIONED SPACE IS REQUIRED TO BE
 INSULATED OR SOLID CORE PER FLORIDA
 ENERGY EFFICIENCY CODE.
  
 5) THE STRUCTURE IS LOCATED IN AN "A8"
 FLOOD ZONE. AN ELEVATION CERTIFICATE
 WILL BE REQUIRED.
  
 6) A DESIGN CERTIFICATION FORM IS
 REQUIRED, UNLESS ALL THE INFORMATION
 REQUIRED ON THE FORM IS ON THE PLANS.
 NOT ALL REQUIRED INFORMATION HAS BEEN
 PROVIDED. INDICATE IF BUILDING IS
 DESIGNED AS OPEN,ENCLOSED,ETC. INDICATE
 THE IMPORTANCE FACTOR, BASIC WIND
 VELOCITY, IF REVIEWED FOR SHEAR WALL
 REQUIREMENTS. SEE FORM ATTACHED.
  
 7) HUGHES AND SEMCO HAVE BEEN PURCHASED
 BY USP AND SOME VALUES HAVE CHANGED.
 PLEASE REVIEW TRUSS CONNECTOR SCHEDULE.
  
 8) INDICATE THE SIZE AND LENGTHS OF THE
 TAPCONS AND WOOD SCREWS THAT ARE TO BE
 USED TO ATTACH THE P.T. 2X8S SHOWN ON
 THE DOOR FRAME DETAIL ON A-6.
  
 9) SPECIFY THE SIZE, NUMBER AND LENGTH
 OF THE FASTENERS THAT WILL BE USED WITH
 THE #7 ALTERNATE CONNECTOR SHOWN ON A-6.
 INDICATE THE UPLIFT THAT THIS CONNECTOR
 IS CAPABLE OF RESISTING.
  
 10) INDICATE THE SPACING OF THE DN 72P8
 FASTENERS USED TO ANCHOR THE DOOR BUCKS
 IN THE BUCK DETAIL ON A-6.
  
 11) PROVIDE BUCK DETAILS FOR THE 8 FEET
 WIDE SLIDING GLASS DOORS. THE BUCK
 DETAIL ON A-6 IS FOR SLIDING GLASS DOORS
 UP TO 6' WIDE.
  
 12) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR GLASS BLOCK. PROVIDE
 FIRE RATING INFORMATION FOR GLASS BLOCK.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 2 Status P Date 2002-04-15 Cont ID  
Sent By sgraham Date 2002-04-15 Time 10:24 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-30 Cont ID  
Sent By sgraham Date 2001-11-30 Time 16:01 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***