| Plan Review Stops For Permit 01110574 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-12-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-12-14 |
Time |
12:11 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-23 |
Time |
11:46 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2001-11-23 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-05 |
Time |
20:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-05 |
Time |
20:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-19 |
Time |
19:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-19 |
Time |
19:29 |
Sent To |
|
|
| Notes |
| 2001-11-19 00:00:00 | ******************* UNSAT ************* | | | | | | 1)NOTE: PLEASE SHOW LOAD CALCUALTIONS, | | | PER 220-3/220-13/220-11 | | | PLEASE SHOW ALL CONTINUOUS LOADS AT | | | 125%. (LIGHTING) ETC. | | | | | | 2)NOTE: PLEASE NOTE MISSING SHOW WINDOW | | | OUTLETS PER 210-62 LOADS PER 220-12A | | | | | | 3)NOTE: PLEASE NOTE MISSING SIGN CIRCUIT | | | PER 600-5. | | | | | | PLEASE USBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-12-10 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-12-10 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-23 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-23 00:00:00 | SEE PLAN MEC APPROVAL 11/19/01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-12-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-08 |
Time |
11:19 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-12-08 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-11-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-29 |
Time |
14:25 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-11-29 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-17 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2001-12-17 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-12-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-04 |
Time |
16:47 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-12-04 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2001-12-04 00:00:00 | DENIED | | | REFERENCE: SPC-94-FACBC-97 | | | | | | 1) COMMENT RESPONSE FOR DRINKING FOUNT- | | | AIN NOT APPROVED. DRINKING FOUNTAIN RE- | | | QUIRED PER SPC TABLE 407. PLEASE COMPLY | | | AND SHOW DETAILS. | | | | | | 2) WILL AIR CHAMBERS BE USED? IF SO ACC- | | | ESS PANELS SHALL BE REQUIRED. AIR CHAM- | | | BERS ALSO NEED TO BE RECHARGEABLE AND | | | REQUIRE SHUT OFF VALVES - DRAIN DOWN | | | VALVES AND PETCOCK ON TOP. IF WATER | | | HAMMER ARRESTORS ARE USED PLEASE IN- | | | DICATE SO ON PLANS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-20 |
Time |
09:42 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-11-20 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2001-11-20 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SPC SEC 407.2.2 REQUIRED FACILITIES | | | SHALL BE DIRECTLY ACCESSIBLE TO THE PUB- | | | LIC THROUGH DIRECT OPENINGS OR CORRIDORS | | | FROM THE AREA OR AREAS THEY ARE INTENDED | | | TO SERVE. DOOR OPENING NOT ACCEPTABLE. | | | PAGE A-1 | | | | | | 2) PAGE A-1, OFFICE DOORS TO OFFICE | | | SHALL NOT OPEN INTO CLEAR FLOOR SPACE OF | | | SINK PER FACBC SEC 4.22.2 | | | | | | 3) PAGE A-1, PER SPC TABLE 407 1 DRINK- | | | ING FOUNTAIN IS REQUIRED. D.F SHALL COM- | | | PLY WITH FACBC SEC 4.15. IF A SINGLE D. | | | F. IS USED PROVISIONS SHALL BE MADE FOR | | | THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING PER FACBC SEC 4.1.3(10). | | | | | | 4) PAGE M-1, WATER PIPING DIAGRAM. IF | | | W/HEATER HAS EMERGENCY PAN, IT SHALL | | | HAVE A 1" DRAIN LINE. AIR CHAMBERS ARE | | | QUICK FIX AND REQUIRE ACCESS PANELS AND | | | SHALL BE RECHARGEABLE PER SPC SEC 607.8. | | | 3. WATER HAMMER ARRESTORS CAN BE INSTALL | | | ED WITH OUT ACCESS PANELS. | | | | | | REVIEW BY KENSTEVENS | | | (561) 659-8096 EXT 8377 |
|
|