Plan Review Details - Permit 01110459
Plan Review Stops For Permit 01110459
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-08-16 Cont ID  
Sent By jwitmer Date 2002-08-16 Time 08:32 Rev Time 1.00
Received By jwitmer Date 2002-08-16 Time 08:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-02-25 Cont ID  
Sent By hpiskura Date 2002-02-25 Time 13:13 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-20 Cont ID  
Sent By jwitmer Date 2001-11-20 Time 07:52 Rev Time 1.00
Received By jwitmer Date 2001-11-20 Time 07:52 Sent To  
Notes
2001-11-20 00:00:00BUILDING PLAN REVIEW
 PERMIT# 01110459
 2201 45TH ST
 COLUMBIA HOSPITAL/ NURSES STATION
 2ND/ 3RD FLOOR
 ARELLANO CONSTRUCTION
 TEL: (305) 994-9901
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
  
 1)- SHEET A-3 WALL PRIORITY LEGAND:
 SBC 704.2.1.4. CORRIDOR PARTITIONS,
 SMOKESTOP PARTITIONS, HORIZONTAL EXIT
 PARTITIONS, EXIT ENCLOSURES AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY & PERMAN-
 ETLY IDENTIFIED WITH SIGNS OR STENCILING
 : FIRE & SMOKE BARRIER PROTECT ALL OPEN-
 INGS.
  
 2)- SHEET A-3 SBC 705.4.1 PROTECTION OF
 PENETRATIONS THROUGH FIRE RATED AND NON-
 FIRE RATED ASSEMBLIES SHALL COMPLY WITH
 705.5(FIRE RATED WALLS) & 705.6 PENETRA-
 TIONS OF HORIZONTAL ASSEMBLIES (FLOORS,
 FLOOR/ CEILING ASSEMBLIES OR A ROOF
 CEILING ASSEMBLIES). REQUIRE A UL LIST-
 ING.
  
 3)- SHEET F-0 IS MISSING THE MINIMUM
 INTERIOR FINISH CLASSIFICATION SBC
 TABLE 803.3.
  
 4)- FL ACCESSIBILITY CODE 4.5. FLOOR
 SURFACES ALONG ACCESSIBLE ROUTES AND IN
 ACCESSIBLE ROOMS, SPACES INCLUDING RAMPS
 AND STAIRS SHALL BE STABLE, FIRM AND
 SLIP RESISTANT. ADDAAG A-5 A STATIC
 COEFFICIENT OF FRICTION OF 0.6 FOR
 ACCESSIBLE ROUTES & 0.8 FOR RAMPS.
  
 5)- TYPE I TYPE II BUILDINGS REQUIRE
 FIRE SPRINKLER PLANS AS PART OF THE
 BUILDING PERMITED PLANS. (2 COPIES).
 FIRE SPRINKLER PERMIT WILL REQUIRE A
 SEPERATE PERMIT, PLANS WITH ASSOCIATED
 FEES.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-05-08 Cont ID  
Sent By btrobaug Date 2002-05-08 Time 17:31 Rev Time 0.00
Received By btrobaug Date 2002-05-08 Time 17:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-02-13 Cont ID  
Sent By dpalmer Date 2002-02-13 Time 07:45 Rev Time 0.00
Received By dpalmer Date 2002-02-13 Time 07:45 Sent To  
Notes
2002-02-13 00:00:00******************** UNSAT ***********
  
 1)NOTE: PLEASE NOTE THAT IN RESPONSE TO
 LETTER FROM: I.C.THOMASSON ASSC. PLEASE
 SHOW LOCATIONS OF OUTLETS TO BE RE-
 -LOCATED. PLEASE SHOW ON LAYOUT OF
 EACH WORK STATION SO WHEN THE ELECTRICAL
 INSPECTOR GOES FOR AN INSPECTION HE CAN
 INSPECT THE ONES BEING CHANGED.
  
  
 PLEASE HAVE EITHER THE ELECTRICAL PLAN
 SHOW OR HAVE THE ELECTRICAL CONTRACTOR
 SUBMIT A DRAWING/SKETCH WHEN IN FOR
 PERMITTING..
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-11-19 Cont ID  
Sent By dpalmer Date 2001-11-19 Time 17:52 Rev Time 0.00
Received By dpalmer Date 2001-11-19 Time 17:51 Sent To  
Notes
2001-11-19 00:00:00**************** UNSAT ***********
  
 1)NOTE: PLEASE NOTE THAT NOTHING WAS
 SUBMITTED FOR REVIEW.
  
 PLEASE SUBMIT FOR REVIEW. IF THERE ARE
 ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-02-25 Cont ID  
Sent By hpiskura Date 2002-02-25 Time 13:13 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-02-13 Cont ID  
Sent By mcarsill Date 2002-02-13 Time 11:02 Rev Time 0.00
Received By mcarsill Date 2002-02-13 Time 11:02 Sent To  
Notes
2002-02-13 00:00:00ON 2.13.02 CALLED ARCHITECT AND
 REQUESTED INFORMATION REGARDING
 PIPE PENETRATION PROTECTION METHODS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-11-19 Cont ID  
Sent By mcarsill Date 2001-11-19 Time 16:06 Rev Time 0.00
Received By mcarsill Date 2001-11-19 Time 16:06 Sent To  
Notes
2001-11-19 00:00:001) NO INTERIOR FINISH CLASSIFICATION
 PROVIDED WITH PLANS. PLEASE INDICATE
 CLASS A,B,OR C FOR WALLS AND CEILINGS.
 2) NO UL NUMBERS PROVIDED FOR PIPE
 PENETRATIONS/SEALANT METHODS.
 3) PROVIDE SEPARATE PLANS AND PERMITS
 FOR FIRE SPRINKLER REMODEL.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-02-25 Cont ID  
Sent By hpiskura Date 2002-02-25 Time 13:16 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-02-25 Cont ID  
Sent By hpiskura Date 2002-02-25 Time 13:14 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2002-02-25 Cont ID  
Sent By hpiskura Date 2002-02-25 Time 13:14 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***