Plan Review Details - Permit 01110376
| Plan Review Stops For Permit 01110376 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-11-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-29 |
Time |
07:32 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-29 00:00:00 | REVISION SUBMITTAL DATE 11/28/01 JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-23 |
Time |
09:53 |
Rev Time |
0.60 |
| Received By |
jwitmer |
Date |
2001-11-23 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-10 |
Time |
19:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-10 |
Time |
19:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-16 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-16 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-20 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-20 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-12-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-11 |
Time |
14:12 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-12-11 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-11-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-27 |
Time |
13:10 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2001-11-27 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2001-11-27 00:00:00 | *******************PROVISO************** | | | | | | | | | 1.PLAN SHEET M-1, EXISTING CORRIDOR | | | INDICATES TO DAMPERS IN A FIRE | | | RATED WALL. DAMPERS ARE NOT SHALL BE | | | IDENTIFIED AS FIRE DAMPERS. | | | | | | 2.PLANS DO NOT PROVIDE INSTALLATION | | | DETAILS FOR FIRE DAMPERS.FIRE | | | DAMPERS SHALL COMPLY WITH THE | | | REQUIREMENTS OF UL 555 AND SHALL | | | BEAR THE LABEL OF AN APPROVED | | | TESTING AGENCY AS PER 1997 SMC | | | 610.1.1. | | | | | | 3.PLANS TO DO INDICATE MATERIAL OF | | | PIPING FOR CONDENSER WATER.PLEASE | | | NOTE SHOULD COPPER PIPE BE INSTALLED | | | IT SHALL BE BRAZED AS PER 1997 SMC | | | TABLE 1205. | | | | | | 4.PLAN SHEET M-2 AND M-3 CONTRADICT | | | TERMINATION OF EMERGENCY DRAIN FOR | | | AUXILIRY DRAIN PAN.EMERGENCY DRAIN | | | LINE SHALL NOT TERMINATE TO RISER AS | | | INDICATED ON PLAN SHEET M-3.DRAIN | | | SHALL COMPLY WITH 1997 SMC 304.8.6.1 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | | 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-01-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-01-04 |
Time |
18:32 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-01-04 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2002-01-04 00:00:00 | REVISION APPROVED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-11-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-11-19 |
Time |
07:32 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-19 00:00:00 | PLUMBING PLAN REVIEW,PROVISO | | | SHTS P-1 & P-3 | | | SEPERATE PERMIT FOR MEDICAL GAS. |
|
|
|