| Plan Review Stops For Permit 01110119 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-09-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-09-09 |
Time |
17:13 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2002-06-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-19 |
Time |
11:11 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2002-06-19 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2002-06-19 00:00:00 | THIRD CHECKLIST: | | | 1-DRAWINGS ARE STILL STRUCTURALLY | | | INCOMPLETE AND CONFUSING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-02-14 |
Time |
19:29 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2002-02-14 |
Time |
19:29 |
Sent To |
|
|
| Notes |
| 2002-02-14 00:00:00 | SECOND CHECKLIST: | | | | | | | | | 1-RESUBMITTED DRAWINGS ARE THE SAME THAT | | | WERE ORIGINALLY SUBMITTED.SOME CHANGES | | | WERE DONE USING WHITEOUT & INFORMATION | | | REQUESTED WAS NOT GIVEN AND/OR NOT | | | PROPERLY ADDRESSED. | | | SEE PREVIOUS CHECKLIST. | | | 2-SOIL TEST REPORT CALLS FOR DEMUCKING. | | | PROVIDE SPECIFICATIONS FOR DEMUCKING | | | AND ENGINEERING SHORING DETAILS AND | | | SPECS TO PROTECT EXISTING STRUCTURE. | | | 3-PROVIDE COMPLETE WALL SECTION/DETAIL | | | SHOWING NEW WALL BETWEEN EXISTING | | | KITCHEN AND NEW FAMILY ROOM. | | | -SHOW HOW ARE NEW TRUSSES SUPPORTED. | | | -WHAT GOING TO BE DONE ABOUT EXISTING | | | OVERHANG. | | | -HOW ARE NEW TRUSSES GOING TO BE | | | SUPPORTED ON EXISTING ROOF. | | | -HOW ARE EXISTING TRUSSES GOING TO BE | | | SUPPORTED WHEN EXISTING BEARING WALL | | | IS GOING TO BE REMOVED? | | | -PROVIDE SHORING DETAILS AND SPECS. | | | 4-DRAW FLOOR PLAN TO A LARGER SCALE WITH | | | SUFFICIENT CLARITY AND DETAIL TO SHOW | | | ALL WALLS, COLUMNS, OPENING DIMENSIONS | | | ETC. (SEC. 104.2.1 CITY AMENDMENTS). | | | 5-SEE PLANS FOR ADDITIONAL COMMENTS AND | | | PLEASE BRING BACK REVIEWED SET AFTER | | | CORRECTIONS ARE DONE TO ORIGINAL | | | DRAWINGS IN ORDER TO EXPEDITE THE | | | REVIEW PROCESS. | | | 6-RESUBMITTAL FEES WILL BE CHARGED. | | | 7-SOIL TEST REPORT NEED TO HAVE ORIGINAL | | | SIGNATURE, SEAL AND DATE BY THE | | | PROFESSIONAL ENGINEER WHEN SUBMITTING | | | DOCUMENTS FOR PUBLIC RECORDS. | | | 8-PROVIDE PRODUCT APPROVAL FOR: | | | A)EXTERIOR REAR DOOR W/ COMPLETE PRODUCT | | | APPROVAL REPORT ND MATCHING DRAWINGS. | | | B)WINDOW MULLIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-12-10 |
Time |
18:52 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2001-12-10 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2001-12-10 00:00:00 | CHECKLIST: | | | 1-FOUNDATION PLAN AND FLOOR PLAN DON'T | | | MATCH. CLEARLY SHOW THE BEARING WALL | | | AND OR COLUMNS REQUIRED TO SUPPORT | | | EXISTING AND PROPOSED ROOF. | | | -CLEARLY SPECIFY PROVISIONS TAKEN TO | | | REINFORCE AREAS FOR NEW OPENINGS ON | | | EXISTING BEARING WALL. SPECIFY BEAMS. | | | 2-SPECIFY SAFETY GLASS WHERE REQUIRED. | | | SEE PLANS AND SEC. 2405.2 SBC 1997. | | | 3-FILL IN DESIGN CERTIFICATION FOR | | | BUILDING CODE COMPLIANCE FORM ATTACHED | | | 4-PROVIDE ATTIC ACCESS AT NEW ROOF AREA. | | | SECTION 2309.6 SBC 1997. | | | 5-PROVIDE COMPLETE STRUCTURAL BUCK | | | DETAILS FOR EXTERIOR DOORS AND WINDOWS | | | SEC. 104.2.2 CITY AMENDMENTS TO SBC/97 | | | 6-PROVIDE COMPLETE AND CLEAR HURRICANE | | | ANCHOR SCHEDULE. ROOF FRAMING PLAN AND | | | WALL SECTIONS SPECIFY DIFFERENT | | | CONNECTORS. | | | -INCLUDE CONNECTORS TO BE USED AT | | | EXISTING BEARING WALL AND NEW TRUSSES. | | | 7-CLEARLY SPECIFY THE DESIGN PRESSURES | | | CALCULATED FOR ALL EXTERIOR OPENINGS. | | | SEC. 1606 SBC 1997. | | | 8-CLEARLY SPECIFY SIZES AND SPACING OF | | | ATTIC VENTS AT FLAT ROOF AREA. ALSO, | | | SPECIFY ATTIC VENTILATION AT TYP. WALL | | | SECTION. SEC. 2309.7 SBC 1997. | | | 9-CLARIFY HOWIS THE TYP. EXTERIOR WALL | | | SECTION GOING TO ACHIEVE INSULATION | | | WITH AN R-11 VALUE. | | | 10-DETAILS SHEET: CLEARLY INDICATE THE | | | DETAILS THAT APPLY TO THIS PROJECT. | | | -INDICATE ON PLANS WHERE ARE THE WALL | | | SECTIONS TAKEN AT. | | | 11-ROOF FRAMING PLAN IS INCOMPLETE. IT | | | DOESN'T MATCH WHAT IS SHOWN ON EXTER'R | | | ELEVATIONS. | | | 12-ROOF PITCH OF 2:12 NEEDS TWO LAYERS | | | OF UNDERLAYMENT. SEC. 1504.2.1 SBC/97. | | | 13-PROVIDE COMPLETE INFORMATION FOR | | | INSTALLATION OF ACCORDION STORM | | | SHUTTERS. PROVIDE KEY PLAN AND CLEARLY | | | INDICATE ON DRAWINGS THE COMPONENTS | | | AND ANCHORS SELECTED FOR THIS SPECIFIC | | | INSTALLATION. | | | 14-SEE PLANS FOR ADDITIONAL COMMENTS AND | | | PLEASE RETURN REVIEWED SET IN ORDER TO | | | EXPEDITE THE REVIEW PROCESS. | | | 15-PROVIDE SOIL TEST REPORT. SECTION | | | 104.2.2 CITY AMENDMENTS TO SBC 1997. | | | 16-ENGINEER TO PROVIDE ALL INFORMATION, | | | INCLUDING HIS LICENSE NUMBER IN ALL | | | DRAWINGS AS REQUIRED BY CHAPTER 471 OF | | | FLORIDA STATUTES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-09-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-04 |
Time |
13:34 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2002-09-04 |
Time |
13:34 |
Sent To |
P |
|
| Notes |
| 2002-09-04 00:00:00 | ***** NOTE /PROVISO / REVISION ******** | | | | | | PLEASE NOTE NOTES REDLINED ON PLANS FOR | | | COMMENTS MADE ON PREVIOUS REVIEWS. | | | | | | | | | 1)NOTE: PLEASE NOTE MASTER BATH RECEPT | | | TO BE WITHIN 3' OF SINK. 210-52D | | | | | | 2)NOTE: PLEASE NOTE THAT PANEL SCHEDULE | | | AND LOAD CALCULATIONS DO NOT CORRELATE. | | | PLEASE NOTE THAT FRIG/LIGHTING/DRYER | | | LOADS ARE DIFFERENT ON EACH?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW BEFORE ROUGH ELECTRICAL INSPECT- | | | -ION IS CALLED IN. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-06-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-11 |
Time |
06:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-06-11 |
Time |
06:18 |
Sent To |
P |
|
| Notes |
| 2002-06-11 00:00:00 | ************** NOTE ************ | | | | | | PLEASE SEEITEMS REDLINED ON PLANS. | | | STILL DO NOT HAVE ITEMS ON PLANS,GONE | | | OVER IN MEETING. | | | DISC FOR EXIST A/C, REC FOR CU. | | | MISSING BATH REC | | | LT FOR ATTIC | | | CORRELATE LOAD CALCS/RISER | | | OUTSIDE GFI | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-11 |
Time |
05:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-11 |
Time |
18:37 |
Sent To |
P |
|
| Notes |
| 2002-02-11 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT NOTHING FROM | | | FIRST REVIEW WAS DONE? | | | | | | PLEASE SEE NOTES ATTACHED FROM FIRST | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-08 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-19 |
Time |
11:56 |
Sent To |
P |
|
| Notes |
| 2001-11-19 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE NOTETHAT ALL SHEETS | | | MUST CONTAIN A TITLE BLOCK FOR THE | | | ENGINEER OF RECORD. PER 61G15-23.002 | | | | | | 2)NOTE: PLEASE NOTE MISSING EGRESS | | | LIGHTING PER 210-70 LEAVING FAMILY ROOM | | | TO OUTSIDE. | | | | | | 3)NOTE: PLEASE NOTE MISSING GFI OUTLET | | | FOR BATHROOM. 210-52D, 210-8 | | | | | | 4) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | 5)NOTE: PLEASE SUBMIT COMPLET LOAD | | | CALCULATIONS FOR SERVICE. 220-3-C-1 | | | | | | 6)NOTE: PLEASE NOTE THAT SERVICE IS | | | SHOWN AS EXSITING 150A PANEL AND 200AMP | | | OCP? PLEASE CLARIFY SERVICE. | | | | | | 7)NOTE: PLEASE ALSO NOTE THAT PARTIAL | | | PANEL SCHEDULE SUBMITTED REFERENCES | | | 150V FOR CIRCUITS?? PLEASE NOTE THAT | | | THIS DOES NOT CORRELATE WITH ANY VOLTAGE | | | -S THAT MAY BE COMMON ON SFR?? | | | | | | 8)NOTE: PLEASE CLARFIY IF EQUIPMENT ON | | | RISER DIAGRAM IS NEW? | | | IF SO, PLEASE SUBMIT AIC RATINGS FOR | | | ANY NEW EQUIPMENT PER 110-9/215-5. | | | | | | 9) NOTE: PLEASE SHOW GROUNDING ELECTRODE | | | GOING TO BUILDING STEEL AND COLD WATER | | | PER 250-50. | | | NEW FOOTER STEEL TO BE INCLUDED. | | | | | | 10)NOTE: PLEASE NOTE THAT ELECTRICAL | | | PLANS ARE TO INCLUDE ANY A/C EQUIPMENT | | | BEING INSTALLED. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2002-09-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-09-04 |
Time |
18:41 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-09-04 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2002-09-04 00:00:00 | NO MECHANICAL PLANS.9/4/01 H.M. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-06-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-09-04 |
Time |
17:39 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-06-19 |
Time |
10:50 |
Sent To |
B |
|
| Notes |
| 2002-06-19 00:00:00 | PROVISO:MECHANICAL PERMIT 01110120 | | | | | | PLEASE SUBMIT ALL NEW DUCT SIZES FOR | | | THEADDITION AS WELL AS ANY NEW DUCTWORK | | | ON THE EXISTING.PROVIDE EQUIPMENT | | | INFORMATION (MAKE, MODEL, BTU/HR & THE | | | SEER OF THE CONDENSER). PROVIDE THIS | | | INFORMATION PRIOR TO INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-02-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-01 |
Time |
08:52 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-02-01 |
Time |
08:45 |
Sent To |
E |
|
| Notes |
| 2002-02-01 00:00:00 | | | | PROVISO: | | | | | | UPGRADING EXISTING 2 1/2 TON SYSTEM TO | | | 3 1/2 TON SYSTEM TO ACCOMMODATE THE | | | ADDITION TO THE EXISTING HOUSE.NEW | | | DUCTWORK FOR ADDITION. | | | | | | SHOULD ANY DUCT ON EXISTING SYSTEM BE | | | REPLACED, A REVISION SHOWING DUCT SIZE | | | AND LOCATION WILL BE REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-11-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-16 |
Time |
08:14 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-11-16 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2001-11-16 00:00:00 | *******************DENIED*************** | | | | | | | | | PLEASE CLARIFY CHANGE OUT OF 2 1/2 TON | | | SYSTEM TO A 3 1/2 TON SYSTEM.PLAN | | | REFLECTS A 450 CFM AIR DISTRIBUTION.A | | | 3 1/2 TON SYSTEM HAS THE CAPACITY FOR | | | 1800 CFM.UNIT IS TO LARGE FOR WHAT | | | PLAN INDICATES IS BEING UTILIZED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-09-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-09-04 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-09-04 |
Time |
17:38 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-04 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-18 |
Time |
12:32 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-11 |
Time |
06:16 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-02-03 00:00:00 | RE-SUB PLANS SIGNED.PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-01 |
Time |
09:07 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-11-20 |
Time |
20:19 |
Sent To |
|
|
| Notes |
| 2001-11-20 00:00:00 | DENIED | | | | | | 1) PLEASE NOTE THAT ALL SHEETS MUST | | | CONTAIM A TITLE BLOCK FOR THE ENGINEER | | | OF RECORD PER 61G15-23.002 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-09-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-09-05 |
Time |
10:16 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|