Plan Review Details - Permit 01110119
Plan Review Stops For Permit 01110119
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-09-09 Cont ID  
Sent By lmartine Date 2002-09-09 Time 17:13 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-06-19 Cont ID  
Sent By pkrauss Date 2002-06-19 Time 11:11 Rev Time 1.50
Received By jgomez Date 2002-06-19 Time 18:50 Sent To  
Notes
2002-06-19 00:00:00THIRD CHECKLIST:
 1-DRAWINGS ARE STILL STRUCTURALLY
 INCOMPLETE AND CONFUSING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-02-14 Cont ID  
Sent By jgomez Date 2002-02-14 Time 19:29 Rev Time 2.00
Received By jgomez Date 2002-02-14 Time 19:29 Sent To  
Notes
2002-02-14 00:00:00SECOND CHECKLIST:
  
  
 1-RESUBMITTED DRAWINGS ARE THE SAME THAT
 WERE ORIGINALLY SUBMITTED.SOME CHANGES
 WERE DONE USING WHITEOUT & INFORMATION
 REQUESTED WAS NOT GIVEN AND/OR NOT
 PROPERLY ADDRESSED.
 SEE PREVIOUS CHECKLIST.
 2-SOIL TEST REPORT CALLS FOR DEMUCKING.
 PROVIDE SPECIFICATIONS FOR DEMUCKING
 AND ENGINEERING SHORING DETAILS AND
 SPECS TO PROTECT EXISTING STRUCTURE.
 3-PROVIDE COMPLETE WALL SECTION/DETAIL
 SHOWING NEW WALL BETWEEN EXISTING
 KITCHEN AND NEW FAMILY ROOM.
 -SHOW HOW ARE NEW TRUSSES SUPPORTED.
 -WHAT GOING TO BE DONE ABOUT EXISTING
 OVERHANG.
 -HOW ARE NEW TRUSSES GOING TO BE
 SUPPORTED ON EXISTING ROOF.
 -HOW ARE EXISTING TRUSSES GOING TO BE
 SUPPORTED WHEN EXISTING BEARING WALL
 IS GOING TO BE REMOVED?
 -PROVIDE SHORING DETAILS AND SPECS.
 4-DRAW FLOOR PLAN TO A LARGER SCALE WITH
 SUFFICIENT CLARITY AND DETAIL TO SHOW
 ALL WALLS, COLUMNS, OPENING DIMENSIONS
 ETC. (SEC. 104.2.1 CITY AMENDMENTS).
 5-SEE PLANS FOR ADDITIONAL COMMENTS AND
 PLEASE BRING BACK REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.
 6-RESUBMITTAL FEES WILL BE CHARGED.
 7-SOIL TEST REPORT NEED TO HAVE ORIGINAL
 SIGNATURE, SEAL AND DATE BY THE
 PROFESSIONAL ENGINEER WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 8-PROVIDE PRODUCT APPROVAL FOR:
 A)EXTERIOR REAR DOOR W/ COMPLETE PRODUCT
 APPROVAL REPORT ND MATCHING DRAWINGS.
 B)WINDOW MULLIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-12-10 Cont ID  
Sent By jgomez Date 2001-12-10 Time 18:52 Rev Time 1.50
Received By jgomez Date 2001-12-10 Time 18:52 Sent To  
Notes
2001-12-10 00:00:00CHECKLIST:
 1-FOUNDATION PLAN AND FLOOR PLAN DON'T
 MATCH. CLEARLY SHOW THE BEARING WALL
 AND OR COLUMNS REQUIRED TO SUPPORT
 EXISTING AND PROPOSED ROOF.
 -CLEARLY SPECIFY PROVISIONS TAKEN TO
 REINFORCE AREAS FOR NEW OPENINGS ON
 EXISTING BEARING WALL. SPECIFY BEAMS.
 2-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS AND SEC. 2405.2 SBC 1997.
 3-FILL IN DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM ATTACHED
 4-PROVIDE ATTIC ACCESS AT NEW ROOF AREA.
 SECTION 2309.6 SBC 1997.
 5-PROVIDE COMPLETE STRUCTURAL BUCK
 DETAILS FOR EXTERIOR DOORS AND WINDOWS
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 6-PROVIDE COMPLETE AND CLEAR HURRICANE
 ANCHOR SCHEDULE. ROOF FRAMING PLAN AND
 WALL SECTIONS SPECIFY DIFFERENT
 CONNECTORS.
 -INCLUDE CONNECTORS TO BE USED AT
 EXISTING BEARING WALL AND NEW TRUSSES.
 7-CLEARLY SPECIFY THE DESIGN PRESSURES
 CALCULATED FOR ALL EXTERIOR OPENINGS.
 SEC. 1606 SBC 1997.
 8-CLEARLY SPECIFY SIZES AND SPACING OF
 ATTIC VENTS AT FLAT ROOF AREA. ALSO,
 SPECIFY ATTIC VENTILATION AT TYP. WALL
 SECTION. SEC. 2309.7 SBC 1997.
 9-CLARIFY HOWIS THE TYP. EXTERIOR WALL
 SECTION GOING TO ACHIEVE INSULATION
 WITH AN R-11 VALUE.
 10-DETAILS SHEET: CLEARLY INDICATE THE
 DETAILS THAT APPLY TO THIS PROJECT.
 -INDICATE ON PLANS WHERE ARE THE WALL
 SECTIONS TAKEN AT.
 11-ROOF FRAMING PLAN IS INCOMPLETE. IT
 DOESN'T MATCH WHAT IS SHOWN ON EXTER'R
 ELEVATIONS.
 12-ROOF PITCH OF 2:12 NEEDS TWO LAYERS
 OF UNDERLAYMENT. SEC. 1504.2.1 SBC/97.
 13-PROVIDE COMPLETE INFORMATION FOR
 INSTALLATION OF ACCORDION STORM
 SHUTTERS. PROVIDE KEY PLAN AND CLEARLY
 INDICATE ON DRAWINGS THE COMPONENTS
 AND ANCHORS SELECTED FOR THIS SPECIFIC
 INSTALLATION.
 14-SEE PLANS FOR ADDITIONAL COMMENTS AND
 PLEASE RETURN REVIEWED SET IN ORDER TO
 EXPEDITE THE REVIEW PROCESS.
 15-PROVIDE SOIL TEST REPORT. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 16-ENGINEER TO PROVIDE ALL INFORMATION,
 INCLUDING HIS LICENSE NUMBER IN ALL
 DRAWINGS AS REQUIRED BY CHAPTER 471 OF
 FLORIDA STATUTES.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-09-04 Cont ID  
Sent By dpalmer Date 2002-09-04 Time 13:34 Rev Time 0.75
Received By dpalmer Date 2002-09-04 Time 13:34 Sent To P
Notes
2002-09-04 00:00:00***** NOTE /PROVISO / REVISION ********
  
 PLEASE NOTE NOTES REDLINED ON PLANS FOR
 COMMENTS MADE ON PREVIOUS REVIEWS.
  
  
 1)NOTE: PLEASE NOTE MASTER BATH RECEPT
 TO BE WITHIN 3' OF SINK. 210-52D
  
 2)NOTE: PLEASE NOTE THAT PANEL SCHEDULE
 AND LOAD CALCULATIONS DO NOT CORRELATE.
 PLEASE NOTE THAT FRIG/LIGHTING/DRYER
 LOADS ARE DIFFERENT ON EACH??
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE ROUGH ELECTRICAL INSPECT-
 -ION IS CALLED IN. IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-06-11 Cont ID  
Sent By dpalmer Date 2002-06-11 Time 06:31 Rev Time 0.00
Received By dpalmer Date 2002-06-11 Time 06:18 Sent To P
Notes
2002-06-11 00:00:00************** NOTE ************
  
 PLEASE SEEITEMS REDLINED ON PLANS.
 STILL DO NOT HAVE ITEMS ON PLANS,GONE
 OVER IN MEETING.
 DISC FOR EXIST A/C, REC FOR CU.
 MISSING BATH REC
 LT FOR ATTIC
 CORRELATE LOAD CALCS/RISER
 OUTSIDE GFI
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-02-11 Cont ID  
Sent By dpalmer Date 2002-02-11 Time 05:53 Rev Time 0.00
Received By dpalmer Date 2002-02-11 Time 18:37 Sent To P
Notes
2002-02-11 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE NOTE THAT NOTHING FROM
 FIRST REVIEW WAS DONE?
  
 PLEASE SEE NOTES ATTACHED FROM FIRST
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-11-19 Cont ID  
Sent By pkrauss Date 2002-02-08 Time 16:33 Rev Time 0.00
Received By dpalmer Date 2001-11-19 Time 11:56 Sent To P
Notes
2001-11-19 00:00:00**************** UNSAT *****************
  
 1)NOTE: PLEASE NOTETHAT ALL SHEETS
 MUST CONTAIN A TITLE BLOCK FOR THE
 ENGINEER OF RECORD. PER 61G15-23.002
  
 2)NOTE: PLEASE NOTE MISSING EGRESS
 LIGHTING PER 210-70 LEAVING FAMILY ROOM
 TO OUTSIDE.
  
 3)NOTE: PLEASE NOTE MISSING GFI OUTLET
 FOR BATHROOM. 210-52D, 210-8
  
 4) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 5)NOTE: PLEASE SUBMIT COMPLET LOAD
 CALCULATIONS FOR SERVICE. 220-3-C-1
  
 6)NOTE: PLEASE NOTE THAT SERVICE IS
 SHOWN AS EXSITING 150A PANEL AND 200AMP
 OCP? PLEASE CLARIFY SERVICE.
  
 7)NOTE: PLEASE ALSO NOTE THAT PARTIAL
 PANEL SCHEDULE SUBMITTED REFERENCES
 150V FOR CIRCUITS?? PLEASE NOTE THAT
 THIS DOES NOT CORRELATE WITH ANY VOLTAGE
 -S THAT MAY BE COMMON ON SFR??
  
 8)NOTE: PLEASE CLARFIY IF EQUIPMENT ON
 RISER DIAGRAM IS NEW?
 IF SO, PLEASE SUBMIT AIC RATINGS FOR
 ANY NEW EQUIPMENT PER 110-9/215-5.
  
 9) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
 NEW FOOTER STEEL TO BE INCLUDED.
  
 10)NOTE: PLEASE NOTE THAT ELECTRICAL
 PLANS ARE TO INCLUDE ANY A/C EQUIPMENT
 BEING INSTALLED.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 4 Status N Date 2002-09-04 Cont ID  
Sent By hmoser Date 2002-09-04 Time 18:41 Rev Time 0.50
Received By hmoser Date 2002-09-04 Time 18:41 Sent To  
Notes
2002-09-04 00:00:00NO MECHANICAL PLANS.9/4/01 H.M.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-06-19 Cont ID  
Sent By kstevens Date 2002-09-04 Time 17:39 Rev Time 0.35
Received By pkrauss Date 2002-06-19 Time 10:50 Sent To B
Notes
2002-06-19 00:00:00PROVISO:MECHANICAL PERMIT 01110120
  
 PLEASE SUBMIT ALL NEW DUCT SIZES FOR
 THEADDITION AS WELL AS ANY NEW DUCTWORK
 ON THE EXISTING.PROVIDE EQUIPMENT
 INFORMATION (MAKE, MODEL, BTU/HR & THE
 SEER OF THE CONDENSER). PROVIDE THIS
 INFORMATION PRIOR TO INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-02-01 Cont ID  
Sent By pkrauss Date 2002-02-01 Time 08:52 Rev Time 0.40
Received By pkrauss Date 2002-02-01 Time 08:45 Sent To E
Notes
2002-02-01 00:00:00 
 PROVISO:
  
 UPGRADING EXISTING 2 1/2 TON SYSTEM TO
 3 1/2 TON SYSTEM TO ACCOMMODATE THE
 ADDITION TO THE EXISTING HOUSE.NEW
 DUCTWORK FOR ADDITION.
  
 SHOULD ANY DUCT ON EXISTING SYSTEM BE
 REPLACED, A REVISION SHOWING DUCT SIZE
 AND LOCATION WILL BE REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-11-16 Cont ID  
Sent By pkrauss Date 2001-11-16 Time 08:14 Rev Time 0.35
Received By pkrauss Date 2001-11-16 Time 07:54 Sent To  
Notes
2001-11-16 00:00:00*******************DENIED***************
  
  
 PLEASE CLARIFY CHANGE OUT OF 2 1/2 TON
 SYSTEM TO A 3 1/2 TON SYSTEM.PLAN
 REFLECTS A 450 CFM AIR DISTRIBUTION.A
 3 1/2 TON SYSTEM HAS THE CAPACITY FOR
 1800 CFM.UNIT IS TO LARGE FOR WHAT
 PLAN INDICATES IS BEING UTILIZED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-09-04 Cont ID  
Sent By kstevens Date 2002-09-04 Time 17:38 Rev Time 0.00
Received By kstevens Date 2002-09-04 Time 17:38 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-06-18 Cont ID  
Sent By dpalmer Date 2002-09-04 Time 14:04 Rev Time 0.00
Received By kstevens Date 2002-06-18 Time 12:32 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-02-03 Cont ID  
Sent By dpalmer Date 2002-06-11 Time 06:16 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-02-03 00:00:00RE-SUB PLANS SIGNED.PES

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-11-20 Cont ID  
Sent By pkrauss Date 2002-02-01 Time 09:07 Rev Time 0.33
Received By kstevens Date 2001-11-20 Time 20:19 Sent To  
Notes
2001-11-20 00:00:00DENIED
  
 1) PLEASE NOTE THAT ALL SHEETS MUST
 CONTAIM A TITLE BLOCK FOR THE ENGINEER
 OF RECORD PER 61G15-23.002
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-09-05 Cont ID  
Sent By sgraham Date 2002-09-05 Time 10:16 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***