| Plan Review Stops For Permit 01110090 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-05-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-31 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-15 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-15 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-04-02 00:00:00 | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO THE | | | COUNTY FOR THE CITY.THEPERMIT PLANS | | | MUST BE STAMPED BY THAT OFFICE AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO | | | THE PERMIT APPLICATION.CALL | | | 561-233-5025 FOR MORE INFORMATION. | | | | | | PLEASE PROVIDE A RECENT SIGNED AND | | | SEALED PROPERTY SURVEY. | | | | | | PROVIDE DOCUMENTATION THAT THE | | | FOUNDATION REQUIREMENTS OF SBC 1803.2 | | | HAVE BEEN ADDRESSED. | | | | | | EGRESS FROM THE EXISTING BUILDING IS NOT | | | PERMITTED THROUGH THE GARAGE.SEE SBC | | | 1001.1.3. | | | | | | EGRESS FROM THE GARAGE MUST COMPLY WITH | | | SBC 1012.1.2 AND 1027.3. THE ELECTRIC | | | SLIDING GATES DO NOT MEET EXIT DOOR | | | REQUIREMENTS. | | | | | | THE 6" STEP SHOWN AT THE STAIR DOORS IS | | | PROHIBITED BY SBC 1012.1.3. | | | | | | SHEET A2 SHOWS WINDOWS IN THE EXISTING | | | BUILDING OPENING INTO THE PROPOSED | | | GARAGE.THIS IS PROHIBITED BY SBC | | | 411.2.6. | | | | | | SBC F102.2.5 REQUIRES TWO STORY | | | BUILDINGS TO BE ONE HOUR PROTECTED. | | | PROVIDE THE FIRE DESIGN NUMBER FOR THE | | | BAR JOIST ROOF SYSTEMS, SEE SBC 701.5.2. | | | | | | SEE ALSO SBC F102.2.6 REGARDING TWO HOUR | | | EXTERIOR WALL RATINGS. | | | | | | GIVEN THAT HURRICANE MISSILE IMPACT | | | RESISTANCE IS REQUIRED FOR THE SECOND | | | FLOOR GLAZING, INDICATE HOW FIRE | | | DEPARTMENT ACCESS IN ACCORDANCE WITH | | | SBC 1405.1 WILL BE ACCOMPLISHED.SEE | | | ALSO SBC 903.5 #2. | | | | | | SHEETS S3 AND S4 INDICATE VARYING ROOF | | | HEIGHTS AND BASE VELOCITY PRESSURES, | | | AND SHEET S8 CITES ASCE 7-93 AS THE | | | DESIGN STANDARD.SBC 1606.1.2 | | | PROHIBITS THE MIXING OF WIND LOADS AND | | | NOTE #1 TO SBC TABLE 1606.2A REQUIRES A | | | SINGLE VELOCITY PRESSURE VALUE FOR THE | | | WHOLE BUILDING.PLEASE REVISE AS | | | NECESSARY AND ENSURE COMPLIANCE WITH | | | SAME. | | | | | | PLEASE PROVIDE A PRESSURE ZONE SKETCH OR | | | TABLE FOR THE WALLS AS WELL AS THE | | | ROOFTO BE USED FOR THE COMPONENTS AND | | | CLADDING. | | | | | | PLEASE PROVIDE A COPY OF THE SOIL | | | ENGINEER'S REPORT. | | | | | | PROVIDE TEST REPORTS AND OR NOTICE OF | | | ACCEPTANCE REPORTS FOR THE WINDOWS, | | | DOORS AND ROOF COVERING. | | | | | | PROVIDE THE TEST DATA FOR THE HURRICANE | | | MISSILE IMPACT RESISTANCE OF THE GLAZED | | | AREAS IN THE EXTERIOR BUILDING ENVELOPE, | | | INCLUDING THE EXISTING BUILDING | | | PORTIONS.SEE THE ATTACHED | | | INTERPRETATION STATEMENT. | | | | | | IS THE BRICK FINISH SHOWN ON SHEET A7 | | | PROPOSED TO BE REAL OR SIMULATED.IF | | | REAL PROVIDE DETAILS OF CONSTRUCTION | | | DEMONSTRATING COMPLIANCE WITH SBC | | | 1403.2. | | | | | | PROVIDE DETAILS FOR THE GUARD RAIL SHOWN | | | IN ELEVATION A8.02 AND THE STAIR | | | HANDRAILS, INCLUDING DESIGN LOADS. SEE | | | SBC 1007.51015 AND 1608.2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-12-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-12-14 |
Time |
08:07 |
Rev Time |
0.25 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-14 00:00:00 | THIS BUILDING WILL BE A TWO STORY | | | STRUCTURE INSIDE THE DESIGNATED FIRE | | | DISTRICT AND IS REQUIRED BY SBC | | | F102.2.5 TO BE 1 HOUR PROTECTED. | | | (APPENDIX F) | | | | | | THE PARKING AREA IS A PARKING GARAGE | | | AND BEING PROPOSED TO BE ZERO LOT LINE, | | | IS REQUIRED BY SBC TABLE 600 TO HAVE 1 | | | HOUR FIRE RATED WALLS WITH NO OPENINGS. | | | | | | | | | GIVEN THE ABOVE REQUIREMENTS, THE GARAGE | | | MUST COMPLY WITH SBC 411.4, MECHANICAL | | | VENTILATION SYSTEMS. | | | | | | AT TIME OF PERMIT APPLICATION INCLUDE A | | | LIFE SAFETY PLAN FOR THE EXISTING | | | BUILDING SHOWING THE EXIT DISCHARGE, | | | SBC 1010, FOR THE REAR EXITS, (EAST | | | SIDE).SEE ALSO SBC 1001.1.3 AS IT | | | APPEARS THAT THEY WILL DISCHARGE INTO | | | THE GARAGE. | | | | | | AT TIME OF PERMIT APPLICATION SHOW HOW | | | THE EXTERIOR GLAZED PORTIONS OF THE | | | BUILDING WILL COMPLY WITH THE CITY'S | | | HURRICANE MISSILE IMPACT REQUIREMENTS. | | | SEE ATTACHED INFORMATION. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO THE | | | COUNTY FOR THE CITY, THE PERMIT PLANS | | | STAMPED BY THAT OFFICE, AND A COPY OF | | | THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. | | | | | | AT TIME OF PERMIT APPLICATION TEST | | | REPORTS OR NOTICE OF ACCEPTANCE REPORTS | | | MUST BE PROVIDED FOR THE WINDOWS, DOORS | | | AND ROOF COVERINGS. | | | | | | SHEET A6.02 SHOWS THE EMERGENCY OVERFLOW | | | SCUPPER LEVEL WITH THE ROOF.SEE SBC | | | 1517.6.4. | | | | | | SHEET A7 SHOWS PLYWOOD ROOF SHEATHING | | | PROPOSED.THE USE OF COMBUSTIBLE | | | COMPONENTS WILL MAKE THIS A TYPE V | | | BUILDING NOT A TYPE IV. SBC TABLE 600 | | | REQUIRES A HIGHER HOURLY FIRE RATING | | | FOREXTERIOR WALLS OF TYPE V | | | CONSTRUCTIONTHAN TYPE IV. REVISE | | | ACCORDINGLY PRIOR | | | TO PERMIT APPLICATION. | | | | | | THE REQUIREMENTS OF SBC 1803.2 MUST BE | | | COMPLIED WITH REGARDING FOUNDATION | | | CONSTRUCTION. | | | | | | THE FIRE DOOR RATING FOR THE STAIR | | | ENCLOSURES MUST COMPLY WITH SBC | | | 705.1.3.4. | | | | | | SHOW THE DETAILS FOR THE EXTERIOR BRICK | | | VENEER IN ACCORDANCE WITH SBC 1403.2. | | | | | | SHEET S-8 CITES ASCE 7-93 AS THE DESIGN | | | STANDARD.SBC 1997 INVOKES ASCE 7-95. | | | PLEASE REVISE AS NECESSARY AND | | | DEMOMNSTRATE COMPLIANCE WITH SAME. SEE | | | SBC 1606.1. | | | | | | THE PLANS DO NOT CLEARLY INDICATE THE | | | DESIGN AND LOADINGS FOR THE VARIOUS | | | HAND AND GUARD RAILS.SEE SBC 1007.5, | | | 1015 AND 1608.2. | | | | | | THE STRUCTURAL PLANS DO NOT DECLARE THE | | | PILING DESIGN LOADS. SEE SBC 1806. | | | | | | NOTE, THIS IS A PAID PLAN REVIEW AND NOT | | | A PERMIT APPLICATION.AT THE PRESENT | | | TIME IT IS LIKELY THAT THE NEW FORIDA | | | BUILDING CODE WILL TAKE EFFECT MARCH 1, | | | 2002. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-11-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-20 |
Time |
17:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-11-25 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-05-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-31 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-31 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-03-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-03-14 |
Time |
06:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-03-13 |
Time |
20:17 |
Sent To |
|
|
| Notes |
| 2002-03-14 00:00:00 | ****************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE WRONG CODE(S) ARE | | | STILL REFERENCED. NOTE MENTIONS, SBCCI | | | FOR ELEC? AND "96" NEC? WE ARE UNDER THE | | | "99" NEC AND ALSO CODES REF IN LOWER | | | NOTES, GIVE CODES FROM '96'. | | | PLEASE CORRECT. | | | | | | 2)NOTE: PLEASE GO OVER LOADS ADDED FOR | | | PANEL "B". | | | PLEASE NOTE THAT ALL CONTINUOUS LOADS | | | NEED TO BE SHOWN AT 125%.230-42/215-2,3 | | | AND 220-13 FOR RECEPT LOADS NOT SHOWN. | | | | | | 3)NOTE: PLEASE NOTE THAT PANEL "A/C" | | | IS SHOWN ON PANEL SCHEDULE AS 3-PHASE, | | | 4 WIRE. PLEASE NOTE ONLY 3 CONDUCTORS | | | ARE SHOWN ON RISER DIAGRAM. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-26 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-26 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2001-11-26 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT NOTE "NOTE 1" | | | ON ELECTRICAL NOTES NEEDS TO REFERENCE | | | LOCAL AMENDMENTS ALSO. | | | | | | 2)NOTE: PLEASE CLARIFY METHOD OF THE | | | EQUIPMENT GROUNDING BETWEEN MAIN DISC`S | | | AND PANELS. 250-122 | | | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 4)NOTE: PLEASE NOTE THE CODES REFERENCED | | | CODES, ARE FROM THE "96" NEC. | | | | | | 5)NOTE: PLEASE SHOW LOAD CALCULATIONS | | | PER 215-5,220-10,220-11,220-3,AND 220-13 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2002-03-19 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-03-19 |
Time |
13:10 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-03-19 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2002-03-19 00:00:00 | PASSED WITH PROVISOS : | | | 1. RESPONSES TO THE REVIEW COMMENTS BY | | | MR. JOHN J. HALEY,P.E. OF HALEY ENGINEER | | | -ING, INC. SATISFACTORY. CONTRACTOR MUST | | | COMPLY WITH THE ITEMS AS INDICATED IN | | | THE LETTER AND IMPLEMENT IN THE FIELD. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2002-03-14 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-03-14 |
Time |
11:37 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-03-14 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2002-03-14 00:00:00 | FAILED : | | | 1. PLEASE REFER TO THE PREVIOUS REVIEW | | | COMMENTS DATED 11-02-01 (PLAN REVIEW). | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-11-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-11-21 |
Time |
14:58 |
Rev Time |
3.00 |
| Received By |
mamini |
Date |
2001-11-21 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2001-11-21 00:00:00 | FAILED : | | | 1. PLEASE PROVIDE STORM WATER CALC. | | | FOR OUR REVIEW AND APPROVAL. | | | 2. PLEASE PROVIDE PERVIOUS AND | | | IMPERVIOUS CALC. FOR ENTIRE SITE. | | | 3. PLEASE STATE IF THE EXISTING METER, | | | WATER SERVICE AND SEWER LATERAL, BACK- | | | FLOW PREVENTERS ARE ADEQUATE, ALL NEW | | | CONNECTIONS HAVE TO BE APPROVED BY | | | UTILITIES DEPARTMENT, 659-8040. | | | 4. PLEASE PROVIDE POLLUTION PREVENTION | | | PLANS FOR ENTIRE SITE, PLANS MUST BE | | | INSTALLED IN FIELED PRIOR ANY EARTH WORK | | | 5. ALL OFF-STREET PARKING MUST BE | | | STRIPED WITH DOUBLE 4" WHITE AND BLUE | | | (H.C). | | | 6. IS THE TYPE C CATCH BASIN LOCATED AT | | | THE SOUTH ENTRACENCE A CONTROL STRUCTURE | | | ALSO THE EXSITING STRUCTURE MUST BE | | | THAT BEING CONNECTED TO MUST BE SHOWN. | | | 7. CITY'S STANDARD MAY BE OBTAINED FROM | | | PUBLIC UTILITIES DEPT. 659-8040. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8482 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2002-06-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-06-05 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-06-06 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2002-06-05 00:00:00 | 1) THE PARKING GARAGE IS REQUIRED TO | | | BE CONTINOUSLY VENTILATED PER THE | | | APPLICABLE CODE REQUIREMENTS FOR | | | ENCLOSED PARKING GARAGES. SINCE NO | | | EMERGENCY POWER IS PLANNED, PLEASE | | | PROVIDE THIS OFFICE IN WRITING THAT | | | SHOULD ELECTRICAL POWER BE LOST, THAT | | | THE ENCLOSED PARKING GARAGE WILL BE | | | CLOSED UNTIL SUCH TIME THAT NORMAL | | | POWER IS RESTORED. | | | | | | 2) ELEVATIONS ON BOTH SIDES OF EXIT | | | DOORS ARE TO BE EQUAL FOR THE WIDTH | | | OF THESE DOORS WHEN OPENED. | | | | | | 3) WHEN THE 60" SECURITY GATES ARE | | | CLOSED HOW DOES THIS COMPROMISE | | | EXITING FROM THE GARAGE. PLEASE | | | EXPLAIN. | | | | | | 4) SINCE THE PARKING GARAGE IS | | | CONSIDERED A CLOSED AND NO FIRE | | | SPRINKLER PROTECTION IS PLANNED, A | | | FIRE ALARM SYSTEM WILL BE REQUIRED AS | | | PER NFPA 88A. PLEASE ADVISE THIS OFFICE | | | HOW THIS WILL BE ACCOMPLISHED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2002-03-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-03-19 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-03-19 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2002-03-19 00:00:00 | PLEASE PROVIDE WRITTEN RESPONSES TO | | | PREVIOUS FIRE PLAN REVIEW NOTES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-12-10 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-12-10 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2001-12-10 00:00:00 | 1) BUILDING ADDRESS REQUIRED PER CITY | | | CODE 3343-00. | | | 2) WHAT PROVISIONS HAVE BEEN MADE FOR | | | FIRE RESCUE ACCESS WHEN THE SECURITY | | | GATES ARE CLOSED. SECURITY GATES REQUIRE | | | SEPARATE PLANS AND PERMITS. | | | 3) A TWO HOUR FIRE SEPARATION IS | | | REQUIRED FROM THE PARKING AREA TO ANY | | | OTHER PARTS OF THE STRUCTURE. | | | 4) PLEASE INDICATE PERCENTAGE OF WALL | | | OPENINGS FOR THE PARKING AREA. PLANS | | | INDICATE ECONO-RAIL MESH PANELS. PLEASE | | | INDICATE ON PLANS IF THE PARKING AREA | | | IS CONSIDERED OPEN OR CLOSED. | | | 5) ELEVATOR TO COMPLY WITH ANSI A17.1. | | | 6) RECEPTION AREA NOTED ON SECOND FLOOR | | | FURNITURE PLAN DOES NOT APPEAR TO ALLOW | | | FOR THE REQUIRED 44" AISLE. | | | 7) HOW IS EXITING ACCOMPLISHED FROM THE | | | PARKING AREA WHEN THE SECURITY GATES | | | ARE CLOSED OR IN THE DOWN POSITION. | | | 8) PLEASE INDICATE ALL FIRE RATINGS | | | FOR THE BUILDING. SINCE NO FIRE | | | SPRINKLERS ARE PRESENT, ALL EXIT ACCESS | | | AREAS ARE TO BE SEPARATED FROM OTHER | | | AREAS BY AT LEAST ONE HOUR. | | | 9) PLEASE EXPLAIN SECURITY FEATURES PLAN | | | NED FOR ANY AND ALL EXIT DOORS. | | | 10) PLEASE INDICATE INTERIOR FINISH FOR | | | WALLS AND CEILINGS OF THE BUILDING. | | | 11) PLEASE PROVIDE FIRE ALARM EQUIPMENT | | | LOCATIONS. | | | 12) PLEASE INDICATE FIRE EXTINGUISHER | | | LOCATIONS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-20 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-15 |
Time |
17:57 |
Sent To |
E |
|
| Notes |
| 2002-11-20 00:00:00 | TO DVP./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-15 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-11-15 |
Time |
16:01 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-06-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-06 |
Time |
14:48 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-06-06 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2002-06-06 00:00:00 | PROVISO: | | | | | | AS PER OUR DISCUSSION ON 5-17-02, | | | EXHAUST FROM GARAGE TO BE IN A 1 HOUR | | | SHAFT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-17 |
Time |
13:36 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-05-17 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2002-05-17 00:00:00 | PROVSIO: | | | | | | AS PER OUR MEETING - PLEASE REVISE PLANS | | | INDICATING 2 HR SHAFT FOR THE EXHAUST | | | DUCT RUNNING FROM THE GARAGE AREA TO | | | THE ROOF. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2002-03-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-18 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2002-03-18 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2002-03-18 00:00:00 | | | | PLAN SHEET M2 INDICATE REFRIGERATION | | | LINES RUNNING THROUGH THE STAIRWELL. | | | AS PER 1997 SBC 1006.1.3.1, | | | PENETRATIONS INTO AND OPENINGS THROUGH | | | A STAIRWAY ENCLOSURE ASSEMBLY ARE | | | PROHIBITED. | | | | | | PROVIDE INFORMATION FOR THE EXHAUST DUCT | | | FOR THE GARAGE.SHOW COMPLIANCE WITH | | | 1997 SMC 610.4, IN BUILDINGS MORE THAN | | | ONE STORY IN HEIGHT, DUCTS EXTENDING | | | THROUGH MORE THAN ON FLOOR SHALL BE | | | PROTECTED BY A SHAFT ENCLOSURE WITH A | | | FIRE RESISTANCE RATING OF NOT LESS THAN | | | 1 HOUR. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-12-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-11 |
Time |
12:53 |
Rev Time |
2.00 |
| Received By |
pkrauss |
Date |
2001-12-11 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2001-12-11 00:00:00 | ********************DENIED************** | | | | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW. | | | | | | 1.PLEASE INDICATE IF GARAGE IS OPEN | | | OR CLOSED AS DEFINED IN THE 1997 SBC | | | 411.3.2 THRU 411.3.4. | | | | | | 2.ENCLOSED PARKING GARAGES SHALL | | | COMPLY WITH 1997 SBC 411.4.2, FOR | | | VENTILATION REQUIREMENTS.PLEASE | | | INDICATE ON PLANS ALL EQUIPMENT AND | | | VENTILATION CALCULATIONS FOR THE | | | GARAGE AREA. | | | | | | 3.CONDENSERS ARE TO BE LOCATED IN THE | | | GARAGE AREA.PROVIDE INFORMATION | | | ON HOW THE EQUIPMENT IS BEING | | | PROTECTED FROM DAMAGE.CONDENSER | | | LOCATED OUTSIDE OF ELEV RM 106, | | | SEEMS TO BE OBSTRUCTING THE ENTRANCE | | | TO THE ELEV RM. | | | | | | 4.PLAN SHEET DUCT PENETRATING THE | | | FLOOR, TO LOBBY AREA (101) DOES NOT | | | INDICATE A FIRE DAMPER. | | | | | | 5.PLAN SHEET M2, RETURN AIR DUCT FOR | | | AHU-4 IS RUNNING THROUGH THE STAIR- | | | WELL # 2.AS PER 1997 SBC | | | 1006.1.3.1,PENETRATIONS INTO AND | | | OPENINGS THROUGH A STAIRWAY | | | ENCLOSURE ASSEMBLY ARE PROHIBITED | | | EXCEPT FOR REQUIRED EXIT DOORS, DUCT | | | WORK & EQUIPMENT NECESSARY FOR | | | INDEPENDENT STAIR PRESSURIZATION, | | | SPRINKLER PIPING, STANDPIPES, AND | | | ELECTRICAL CONDUIT SERVING THE | | | STAIRWAY AND TERMINATING AT A STEEL | | | BOX NOT EXCEEDING 16 SQ IN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-06-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-08 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-08 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2002-06-08 00:00:00 | PASSED FOR 1 SET OF PLANS - 2 SETS REQD. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-03-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-03-25 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-03-25 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2002-03-25 00:00:00 | DENIED | | | REFERENCE: SPC-94-FACBC-97 | | | | | | 1) SHTS A3/A12 KITCHEN SINK ELEVATION. | | | PLEASE SHOW ALL SUBSECTIONS OF SEC 4.24 | | | ON DETAIL. SEE SECS 4.24.2 THRU 4.24.7. | | | 2) SHT P4 WATER HEATER. SHOW DETAIL ON | | | HOW HEATER WILL BE READILY ACCESSIBLE. | | | GIVE HEATER DIMENSIONS AND CABINED DOOR | | | DIMENSIONS. WATER HEATER SHALL BE ABLE | | | TO BE REMOVED WITH OUT REMOVING DISH | | | WASHER. | | | 4) ACCESS PANELS SHALL BE REQUIRED FOR | | | ALL WATER HAMMER ARRESTORS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-11-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-28 |
Time |
17:52 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2001-11-28 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2001-11-28 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SHT CV, GEN NOTES #3, 1999 SO. FLA. | | | BLDG CODE BROWARD CO. EDITION SHOULD | | | READ STANDARD BLDG CODE 1997. | | | 2) SHT A3 LUNCH ROOM 214, SINK TO COMPLY | | | WITH FACBC 2.24. PLEASE SHOW DETAILS. | | | 3) STH P4 PER MODEL COUNTYWIDE AMEND- | | | MENTS TO SPC-94 SEC 607.7 ONLY 2 FIX- | | | TURES ON 1/2" COLD WATER LINE AND ONLY | | | 4 FIXTURES ON 1/2" HOT. PLEASE CHANGE | | | COLD WATER LINE TO TOILET ROOMS TO RE- | | | FLECT WATER RISER DIAGRAM. | | | 4) SHT P4 PER MODEL COUNTYWIDE AMEND- | | | MENTS TO SPC SEC 507.8.1, 1" DRAIN REQ- | | | UIRED FOR PAN DRAIN FOR WATER HEATER. | | | 5) ALL WATER HEATERS ON SHELVES TO HAVE | | | PERMINATE SHIPS LADDER AND MINIMUM WORK- | | | ING PLATFORM 30"X30". EITHER PROVIDE A | | | DETAIL FOR THESE OR PUT HEATER ON FLOOR. | | | 6) SHT P5 WATER HEATER DETAIL, P/T AND | | | PAN DRAIN TO RUN SEPARATELY. SPC SEC | | | 507.8.4. | | | 7) SHT P5 PLUMB. NOTES #5 SANITARY DRAIN | | | AGE MATERIAL SHALL BE EITHER PVC OR CAST | | | IRON, NOT ONE MATERIAL IN WALLS AND THE | | | OTHER OUTSIDE WALLS. | | | 8) SHT P6 SANT RISER DIAGRAM, 2-WAY C/O | | | REQUIRED NEAR JUNCTION OF BLDG DRAIN AND | | | BLDG SEWER. | | | 9) SHT P6, PLEASE INDICATE WATER HAMMER | | | ARRESTORS ON WATER RISER DIAGRAM. AIR | | | CHAMBERS REQUIRE ACCESS PANELS AND SHALL | | | BE RECHARGEABLE IF USED. PLEASE INDICATE | | | BRAND AND MODEL # OF WATER HAMMER ARRES- | | | TORS. | | | 10) SHTS A6 & P7, PLEASE PROVIDE ROOF | | | DRAINAGE CALCULATIONS FOR PRIMARY AND | | | SECONDARY DRAINS. SIZE PER SPC SEC 1108 | | | & 1109. INCLUDE 1/2 AREA OF ALL VERTICAL | | | WALLS INCLUDING PARAPET WALLS 1108.3. | | | ALSO INCLUDE AREA OF ROOF THAT DRAINS ON | | | TO ROOF. PLEASE PROVIDE STORM RISER DIA- | | | GRAM. INCLUDE PIPE SIZE AND SQ FT AREA | | | DRAINED FOR EACH SECTION OF PIPE AND FOR | | | EACH DRAIN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2002-05-09 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-05-09 |
Time |
11:49 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2002-03-14 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-03-14 |
Time |
08:34 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-14 00:00:00 | URBAN DESIGN WAITING FOR INFORMATION | | | FOR ARCHITECT AS PER J MINICOZZI |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-11-19 |
Time |
13:03 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |