Plan Review Details - Permit 01101790
Plan Review Stops For Permit 01101790
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-02-07 Cont ID  
Sent By jgomez Date 2002-02-07 Time 19:27 Rev Time 0.33
Received By jgomez Date 2002-02-07 Time 19:27 Sent To  
Notes
2002-02-07 00:00:00ROOF FRAMING REVISION. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-18 Cont ID  
Sent By jgomez Date 2001-12-18 Time 18:24 Rev Time 2.50
Received By jgomez Date 2001-12-17 Time 16:44 Sent To  
Notes
2001-12-18 00:00:00APPROVED WITH PROVISO:
 1-PRODUCT APPROVAL FOR FRENCH DOORS IS
 EXPIRED. SUBMIT UPDATED PRODUCT
 APPROVAL.
 2-DESIGNER OF RECORD TO REVIEW ALL
 TRUSS DRAWINGS PRIOR TO SUBMITTAL.
 USE STANDARD REVIEW STAMP.
 3-PROVIDE ATTIC ACCESS AT NEW ADDITION
 AS REQUIRED BY SEC. 2309.6 SBC 1997.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-21 Cont ID  
Sent By jgomez Date 2001-11-21 Time 15:33 Rev Time 2.00
Received By jgomez Date 2001-11-21 Time 15:33 Sent To  
Notes
2001-11-21 00:00:00CHECKLIST:
 1-PROVIDE SOIL TEST REPORT. THIS IS THE
 INFORMATION THAT ENGINEER'S USE FOR
 DESIGNING THE FOUNDATION.
 2-SPECIFY SIZE OF WINDOWS REPLACED AT
 BEDROOMS IN ORDER TO VERIFY MINIMUM
 OPENING CLEARANCES FOR EGRESS AS REQ'D
 BY SECTION 1005.4 SBC 1997.
 3-PROVIDE ATTIC ACCESS AS REQUIRED BY
 SECTION 2309.6 SBC 1997.
 4-PROVIDE ENERGY CALCULATIONS FOR THE
 ADDITION AND FOR THE RENOVATION AS
 REQUIRED BY THE FLORIDA ENERGY
 EFFICIENCY CODE FOR BUILDING, 1997 ED.
 5-PROVIDE STRUCTURAL BUCK DETAILS FOR
 DOORS AND WINDOWS. SECTION 104.2.2 OF
 CITY AMENDMENTS TO SBC 1997.
 6-PROVIDE COMPLETE CONSTRUCTION DETAIL
 FOR INSTALLATION OF FRENCH DOORS TO
 STEEL TUBE BY MASTER BEDROOM. SPECIFY
 ALL FASTENERS.
 NOTE: SEE DOORS' PRODUCT APPROVAL
 DRAWINGS TO ASSURE THAT INSTALLATION
 WILL MEET THE PRODUCT APPROVAL SPECS.
 7-SPECIFY FIREBLOCKING WHERE REQUIRED.
 SEE DWGS AND SECTION 2305 SBC 1997.
 8-SPECIFY ATTIC VENTILATION AS REQUIRED
 BY SECTION 2309.7 SBC 1997.
 9-PROVIDE 2 PRODUCT APPROVALS FOR:
 A)ROOF SHINGLES. B)FRENCH DOORS-IMPACT
 C)SLIDING GLASS DOORS-IMPACT. D)SINGLE
 HUNG WINDOWS-IMPACT. E)CASEMENT WIND.
 -IMPACT. F)FIXED WINDOWS-IMPACT. NOTE:
 SEE SIZES SHOWN ON ARCHITECTURAL PLANS
 G)WINDOW MULLIONS-IMPACT. H)AWNING
 WINDOWS-IMPACT. I)ENTRY DOORS-IMPACT.
 10-SEE COMMENTS ON PLANS, INCLUDING THE
 OTHER TRADES AND RETURN REVIEWED SET
 AFTER ALL CORRECTIONS ARE DONE TO THE
 ORIGINAL DRAWINGS IN ORDER TO EXPEDITE
 THE REVIEW PROCESS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-12-10 Cont ID  
Sent By dpalmer Date 2001-12-10 Time 19:39 Rev Time 0.00
Received By dpalmer Date 2001-12-10 Time 19:39 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-05 Cont ID  
Sent By dpalmer Date 2001-11-05 Time 17:22 Rev Time 0.00
Received By dpalmer Date 2001-11-05 Time 17:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-03-28 Cont ID  
Sent By hmoser Date 2002-03-28 Time 20:05 Rev Time 0.50
Received By hmoser Date 2002-03-28 Time 20:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-12-12 Cont ID  
Sent By pkrauss Date 2001-12-12 Time 12:37 Rev Time 0.45
Received By pkrauss Date 2001-12-12 Time 11:54 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-11-02 Cont ID  
Sent By dpalmer Date 2001-12-10 Time 19:41 Rev Time 0.35
Received By pkrauss Date 2001-11-02 Time 13:37 Sent To  
Notes
2001-11-02 00:00:00*******************DENIED***************
  
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE PROVIDE THE FOLLOWING IN
 FORMATION FOR REVIEW.
  
 1.MANUFACTURER, MODEL, BTU AND SEER
 OF NEW A/C EQUIPMENT BEING INSTALLED
  
 2.INDICATE LOCATION OF AHU.
  
 3.INDICATE SIZE AND OF CONDENSATE,
 LIQUID AND SUCTION LINES.
  
 4.TERMINATION OF CONDENSATE.
  
 5.INDICATE SIZE, MATERIAL AND R-VALUE
 OF DUCTWORK.
  
 6.PROVIDE ENERGY AND MANUAL J
 CALCULATIONS AS PER FLORIDA ENERGY
 CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-12-20 Cont ID  
Sent By kstevens Date 2001-12-20 Time 07:47 Rev Time 0.50
Received By kstevens Date 2001-12-20 Time 07:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-31 Cont ID  
Sent By pkrauss Date 2001-12-12 Time 12:37 Rev Time 0.33
Received By kstevens Date 2001-10-31 Time 19:40 Sent To  
Notes
2001-10-31 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) PLEASE PROVIDE A SANITARY RISER DIA-
 GRAM SHOWING HOW EACH SECTION OF RISERS
 TIE INTO EXISTING PLUMBING DRAIN LINES.
 2) MASTER BATH RISER DOES NOT SHOW ALL
 FIXTURES. SHOWER AND LAV ARE MISSING.
 3) WATER SERVICE SHALL HAVE BACKFLOW
 INSTALLED BY PLUMBING CONTRACTOR.
 4) MINIMUM 30" REQUIRED OPENING FOR W/C
 IN EXISTING BATHROOM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-31 Cont ID  
Sent By sgraham Date 2001-10-31 Time 12:25 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***