Plan Review Details - Permit 01101103
| Plan Review Stops For Permit 01101103 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-12-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-12-19 |
Time |
16:55 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-12-19 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2001-12-19 00:00:00 | SECOND CHECKLIST: | | | 1-OWES $11.22 FOR ADJUSTED VALUE AND | | | RADON FEES. PLEASE, BRING COPY OF | | | PAID RECEIPT. | | | 2-NEED TO RECORD NOTICE OF COMMENCEMENT | | | IN THE COURTHOUSE BUILDING. | | | 3-ENGINEER TO RE-REVISE THE DESIGN | | | CERTIFICATION FOR BUILDING CODE | | | COMPLIANCE FORM. ENGINEER DIDN'T SEE | | | REFERENCED TABLES IN SBC 1997 IN ORDER | | | TO APPLY THE CORRECT IMPORTANCE FACTOR | | | AND BASIC VELOCITY PRESSURE. | | | **ENGINEER TO PROVIDE ALL HIS INFORMAT'N | | | AT THE BOTTOM OF FORM, INCLUDING | | | CERTIFICATION # AS REQUIRED BY CHAPTER | | | 471 OF FLORIDA STATUTES. | | | **ENGINEER TO SPECIFY PROJECT NAME AND | | | ADDRESS ON TOP OF FORM. | | | 4-ENGINEER TO PROVIDE COMPLETE SPECS FOR | | | STRUCTURAL GUTTER. THIS IS PART OF HIS | | | DESIGN AND SHALL BE PART OF HIS SIGNED | | | AND SEALED DRAWINGS. (SPECIFY GUTTER | | | MATERIALS AND THICKNESS). SECTION | | | 104.2.2 CITY AMENDMENTS TO SBC 1997. | | | INFORMATION SUBMITTED IS ONLY THE | | | SALES BROCHURE. | | | 5-PROVIDE DETAIL SHOWING ATTACHMENT OF | | | 2X6 & 2X5 BEAM TO THE WALL & TO COL. | | | 6-CLEARLY INDICATE ON ENGINEERED DWGS | | | ALL THE COMPONENTS THAT APPLY FOR | | | THIS PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-10-26 |
Time |
18:04 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2001-10-26 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2001-10-26 00:00:00 | CHECKLIST: | | | | | | 1-CONSTRUCTION VALUE DECLARED WAS TOO | | | LOW. IT WAS ADJUSTED TO $3000. TO | | | REFLECT LABOR AND MATERIALS. | | | -OWES $11.22 FOR UPDATED VALUE & RADON | | | FEES. PLEASE BRING PAID RECEIPT. | | | 2-NEED TO RECORD NOTICE OF COMMENCEMENT | | | IN THE COURTHOUSE. | | | 3-ENGINEER TO REVISE THE DESIGN | | | CERTIFICATION FOR BUILDING CODE | | | COMPLIANCE FORM. THE MEAN ROOF HEIGHT | | | AND VELOCITY PRESSURE DON'T MATCH: | | | SEE TABLE 1606.2A ON THE SBC 1997. | | | ALSO, REVISE THE IMPORTANCE FACTOR: | | | SEE TABLE 1606 OF SBC 1997. | | | 4-ENGINEER TO PROVIDE COMPLETE SPECS FOR | | | STRUCTURAL GUTTER. | | | 5-DIMENSIONS GIVEN ON THE ENGINEER'S | | | DRAWINGS AND THE SURVEY DON'T MATCH. | | | SEE SURVEY AND REVISE ACCORDINGLY. | | | 6-IF SCREEN AREA WILL HAVE A DOOR, THEN | | | SPECIFY SIZE IN ORDER TO VERIFY | | | COMPLIANCE WITH EGRESS REQUIREMENTS | | | OF TABLE 1004 OF SBC 1997. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-10-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-10-25 |
Time |
13:33 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|