Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-12-19 Cont ID  
Sent By jgomez Date 2001-12-19 Time 16:55 Rev Time 1.00
Received By jgomez Date 2001-12-19 Time 16:55 Sent To  
Notes
2001-12-19 00:00:00SECOND CHECKLIST:
 1-OWES $11.22 FOR ADJUSTED VALUE AND
 RADON FEES. PLEASE, BRING COPY OF
 PAID RECEIPT.
 2-NEED TO RECORD NOTICE OF COMMENCEMENT
 IN THE COURTHOUSE BUILDING.
 3-ENGINEER TO RE-REVISE THE DESIGN
 CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM. ENGINEER DIDN'T SEE
 REFERENCED TABLES IN SBC 1997 IN ORDER
 TO APPLY THE CORRECT IMPORTANCE FACTOR
 AND BASIC VELOCITY PRESSURE.
 **ENGINEER TO PROVIDE ALL HIS INFORMAT'N
 AT THE BOTTOM OF FORM, INCLUDING
 CERTIFICATION # AS REQUIRED BY CHAPTER
 471 OF FLORIDA STATUTES.
 **ENGINEER TO SPECIFY PROJECT NAME AND
 ADDRESS ON TOP OF FORM.
 4-ENGINEER TO PROVIDE COMPLETE SPECS FOR
 STRUCTURAL GUTTER. THIS IS PART OF HIS
 DESIGN AND SHALL BE PART OF HIS SIGNED
 AND SEALED DRAWINGS. (SPECIFY GUTTER
 MATERIALS AND THICKNESS). SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 INFORMATION SUBMITTED IS ONLY THE
 SALES BROCHURE.
 5-PROVIDE DETAIL SHOWING ATTACHMENT OF
 2X6 & 2X5 BEAM TO THE WALL & TO COL.
 6-CLEARLY INDICATE ON ENGINEERED DWGS
 ALL THE COMPONENTS THAT APPLY FOR
 THIS PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-26 Cont ID  
Sent By jgomez Date 2001-10-26 Time 18:04 Rev Time 0.50
Received By jgomez Date 2001-10-26 Time 18:04 Sent To  
Notes
2001-10-26 00:00:00CHECKLIST:
  
 1-CONSTRUCTION VALUE DECLARED WAS TOO
 LOW. IT WAS ADJUSTED TO $3000. TO
 REFLECT LABOR AND MATERIALS.
 -OWES $11.22 FOR UPDATED VALUE & RADON
 FEES. PLEASE BRING PAID RECEIPT.
 2-NEED TO RECORD NOTICE OF COMMENCEMENT
 IN THE COURTHOUSE.
 3-ENGINEER TO REVISE THE DESIGN
 CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM. THE MEAN ROOF HEIGHT
 AND VELOCITY PRESSURE DON'T MATCH:
 SEE TABLE 1606.2A ON THE SBC 1997.
 ALSO, REVISE THE IMPORTANCE FACTOR:
 SEE TABLE 1606 OF SBC 1997.
 4-ENGINEER TO PROVIDE COMPLETE SPECS FOR
 STRUCTURAL GUTTER.
 5-DIMENSIONS GIVEN ON THE ENGINEER'S
 DRAWINGS AND THE SURVEY DON'T MATCH.
 SEE SURVEY AND REVISE ACCORDINGLY.
 6-IF SCREEN AREA WILL HAVE A DOOR, THEN
 SPECIFY SIZE IN ORDER TO VERIFY
 COMPLIANCE WITH EGRESS REQUIREMENTS
 OF TABLE 1004 OF SBC 1997.