Plan Review Details - Permit 01101061
Plan Review Stops For Permit 01101061
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-01-18 Cont ID  
Sent By kstevens Date 2002-01-18 Time 16:25 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2002-01-18 00:00:00APPROVED BY L. MARTINEZ

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-03 Cont ID  
Sent By jwitmer Date 2002-01-03 Time 10:55 Rev Time 0.25
Received By jwitmer Date 2002-01-03 Time 10:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-11-02 Cont ID  
Sent By jwitmer Date 2001-11-02 Time 08:53 Rev Time 1.00
Received By jwitmer Date 2001-11-02 Time 08:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-01-22 Cont ID  
Sent By dpalmer Date 2002-01-22 Time 12:33 Rev Time 0.00
Received By dpalmer Date 2002-01-22 Time 12:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-12-26 Cont ID  
Sent By dpalmer Date 2001-12-26 Time 20:07 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-12-26 Cont ID  
Sent By dpalmer Date 2001-12-26 Time 20:05 Rev Time 0.00
Received By dpalmer Date 2001-12-26 Time 20:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-30 Cont ID  
Sent By dpalmer Date 2001-10-30 Time 21:01 Rev Time 0.00
Received By dpalmer Date 2001-10-30 Time 21:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-01-22 Cont ID  
Sent By mcarsill Date 2002-01-22 Time 09:39 Rev Time 0.00
Received By mcarsill Date 2002-01-22 Time 09:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-12-17 Cont ID  
Sent By mcarsill Date 2001-12-17 Time 08:37 Rev Time 0.00
Received By mcarsill Date 2001-12-17 Time 08:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-10-16 Cont ID  
Sent By mcarsill Date 2001-10-16 Time 13:29 Rev Time 0.00
Received By mcarsill Date 2001-10-16 Time 13:22 Sent To  
Notes
2001-10-16 00:00:001) PLEASE PROVIDE DETAILS ON EXISTING
 DOOR E NOTED ON THE PLANS.
 2) THE PLANS SEEM TO INDICATE THAT
 CLASS C INTERIOR FINISH WILL BE
 PROVIDED. PLEASE BE ADVISED THAT THE
 PLANS INDICATES THAT NO FIRE SPRINKLERS
 WILL BE PRESENT AND IF THAT IS THE CASE
 THE INTERIOR FINISH MUST BE AT LEAST
 CLASS A OR B IN THE EXITS.
 3) PLEASE INDICATE ON THE PLANS THE
 NUMBER OF STORIES THE EXISTING
 BUILDING IS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-01-25 Cont ID  
Sent By pkrauss Date 2002-01-25 Time 15:04 Rev Time 0.40
Received By pkrauss Date 2002-01-25 Time 14:52 Sent To  
Notes
2002-01-25 00:00:00 
 MECHANICAL PERMIT REQUIRED.
  
 NOTE:2000 FLORIDA BUILDING CODE,
 (MECHANICAL)

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-12-19 Cont ID  
Sent By pkrauss Date 2001-12-19 Time 15:10 Rev Time 0.45
Received By pkrauss Date 2001-12-19 Time 15:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-10-29 Cont ID  
Sent By pkrauss Date 2001-10-29 Time 14:32 Rev Time 0.45
Received By pkrauss Date 2001-10-29 Time 13:36 Sent To  
Notes
2001-10-29 00:00:00******************DENIED****************
  
  
 PLEASE PROVIDE DETAIL SHOWING HOW
 CONDENSER UNIT STAND WILL BE ATTACHED
 TO THE ROOF.PLEASE NOTE 18" MINIMUM
 BETWEEN THE ROOF SURFACE TO THE BOTTOM
 OF THE SUPPORT RAIL.
  
 PLEASE INDICATE TERMINATION OF EMERGENCY
 DRAIN FROM THE AUXILIARY DRAIN PAN.
 TERMINATION SHALL BE AT A CONSPICUOUS
 POINT TO SERVE AS AN ALARM THAT THE
 REGULAR DRAIN IS RESTRICTED. 1997 SMC
 304.8.6.1.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-03-25 Cont ID  
Sent By kstevens Date 2002-03-25 Time 15:24 Rev Time 0.00
Received By kstevens Date 2002-03-25 Time 15:24 Sent To  
Notes
2002-03-25 00:00:00REVISION OK - SANT RISER DIAGRAM - ADD
 SERVICE SINK REQUIRED PER FBC-2001

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-01-30 Cont ID  
Sent By kstevens Date 2002-01-30 Time 11:41 Rev Time 0.00
Received By kstevens Date 2002-01-30 Time 11:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-01-09 Cont ID  
Sent By kstevens Date 2002-01-09 Time 15:50 Rev Time 0.75
Received By kstevens Date 2002-01-09 Time 15:49 Sent To  
Notes
2002-01-09 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) SHT 1.1 SQ FOOTAGE IS 3033, MINUS
 SQ FOOTAGE FOR RESTROOMS IS APPROX
 2900 SQ FT. @ 100 PERSONS PER SQ FT = 29
 2 WC'S AND 2 LAV'S ARE REQUIRED FOR
 WOMENS RESTROOM. PLEASE RESUBMIT PLANS
 WITH PROPER MINIMUM FACILITIES SHOWN
 SPC TABLE 407
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-30 Cont ID  
Sent By kstevens Date 2001-10-30 Time 13:15 Rev Time 0.75
Received By kstevens Date 2001-10-30 Time 13:15 Sent To  
Notes
2001-10-30 00:00:00DENIED
 REFERENCES: SPC-94 - FACBC-97
  
 1) SUBMIT CALCULATIONS FOR MINIMUM FAC-
 ILITIES PER SPC TABLE 407. PAGE 3.1
 2) PAGE MP-1 DRINKING FOUNTAIN. PLEASE
 SHOW DRINKING FOUNTAIN DETAIL TO SHOW
 COMPLIANCE WITH FACBC-97 SEC 4.15. IF A
 SINGLE DRINKING FOUNTAIN SPOUT TO BE 36"
 OFF FLOOR AND PROVISIONS SHALL BE MADE
 FOR THOSE THAT HAVE DIFFICULTY BENDING
 OR STOOPING.
 3) PAGE MP-1 WATER RISER. WATER HAMMER
 ARRESTORS SHALL BE INSTALLED PER MANU-
 FACTURE INSTALLATION INSTRUCTIONS AND
 WH-PDI 201. ARRESTORS SHALL BE LOCATED
 NEAR FIXTURES NOT AT TOP OF DROP AS IN-
 DICATED ON RISER.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377