Plan Review Details - Permit 01101028
Plan Review Stops For Permit 01101028
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-31 Cont ID  
Sent By dpalmer Date 2001-10-31 Time 14:00 Rev Time 0.00
Received By dpalmer Date 2001-10-31 Time 14:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-10-27 Cont ID  
Sent By hmoser Date 2001-10-27 Time 08:56 Rev Time 0.50
Received By hmoser Date 2001-10-27 Time 08:56 Sent To  
Notes
2001-10-27 00:00:00NO MECHANICAL PERMIT NUMBER ON THIS
 APPLICATION
 H.M.10/27/01

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-10-22 Cont ID  
Sent By kstevens Date 2001-10-22 Time 20:25 Rev Time 0.33
Received By kstevens Date 2001-10-22 Time 20:24 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status   Date 2001-12-18 Cont ID  
Sent By rmcdouga Date 2001-12-17 Time 11:39 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-12-04 Cont ID  
Sent By rmcdouga Date 2001-12-03 Time 16:54 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-12-03 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) PROVIDE CITY OF WPB DESIGN
 CERTIFICATION FORM SIGNED AND SEALED BY
 DESIGNER OF RECORD OR PROVIDE ALL OF THE
 INFORMATION ON THE PLANS.
  
 4) PROVIDE AT LEAST ONE BATHROOM WITH A
 DOOR THAT HAS A 29" CLEAR OPENING TO
 TOILET FACILITIES. 97 FLORIDA
 ACCESSIBILITY CODE
  
 5) THE GLASS BLOCK LOCATED IN THE MASTER
 BATH IS REQUIRED TO HAVE A UNIFORM FACE
 THICKNESS OF 0.25 INCH PER 97 SBC SECT.
 2405.2.2(5) FOR GLAZING IN HAZARDOUS
 LOCATIONS.
  
 6) PROVIDE FRAMING DETAILS FOR ROUND
 WINDOW AT CABANA BATH.
  
 7) SEMCO AND HUGHES HAVE BEEN PURCHASED
 BY UNITED STEEL PRODUCTS. PLEASE NOTE
 THAT SOME OF THE CONNECTORS VALUES HAVE
 CHANGED AND OTHERS ARE DISCONTINUED.
 PLEASE REVIEW AND REVISE CONNECTOR
 SCHEDULE AS NECESSARY. CHECK WITH THE
 MANUFACTURER FOR VALUES WHEN USING LESS
 THAN THE NUMBER OR SIZE OF FASTENERS
 SPECIFIED BY THE CATALOG AND WHEN
 ANCHORS ARE SPACED LESS THAN 8" APART.
  
 8) THE HUS 210 HANGER CAN NOT BE
 MODIFIED AS INDICATED BY DETAIL 11 ON
 A-9. REBENDING THE FLANGE WILL WEAKEN
 THE HANGER. PLEASE INDICATE AN
 APPROPRIATE HANGER.
  
 9) THE DETAIL FOR THE GIRDER HANGER AT
 THE COVERED PATIO (NEAR CABANA BATH) IS
 INCORRECTLY REFERENCED AS DET.5/A-5 ON
 SHEET A-6.
  
 10) THE PRODUCT APPROVALS FOR THE ROOF
 TILES AND THE SINGLE HUNG WINDOWS
 EXPIRED PRIOR TO APPLICATION FOR PERMIT.
 PLEASE SUBMIT CURRENT PRODUCT APPROVALS.
  
 11)PROVIDE PRODUCT APPROVAL FOR EXTERIOR
 DOOR WITH SIDELITE AS INDICATED ON PLANS
 AT FRONT ENTRY. THE GLAZING IN THIS
 ASSEMBLY WILL REQUIRE IMPACT GLASS OR
 STORM PANELS.
  
 12) PROVIDE CITY OF WPB SITE SPECIFIC
 PRODUCT APPROVAL FORM FOR BUTT GLASS
 ASSEMBLY IN ADDITION TO DRAWING. THE
 FORM MUST BE SIGNED, SEALED AND DATED BY
 THE ENGINEER CERTIFYING THE PRODUCT AND
 BY THE DESIGNER OF RECORD FOR THE
 STRUCTURE APPROVING IT FOR USE IN THE
 STRUCTURE.
  
 13) PROVIDE PRODUCT APPROVALS FOR THE
 LARGE ARCHED TOP FIXED GLASS WINDOWS.
 THE PRODUCT APPROVALS SUBMITTED ARE FOR
 F.G.WINDOWS WITH A MAXIMUM HEIGHT OF 60"
 AND A MAXIMUM WIDTH OF 120".
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-24 Cont ID  
Sent By sgraham Date 2001-10-24 Time 10:11 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***