Plan Review Details - Permit 01101022
| Plan Review Stops For Permit 01101022 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-20 |
Time |
21:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-20 |
Time |
21:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-11-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-11-27 |
Time |
18:53 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2001-11-27 |
Time |
18:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-11-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2002-11-07 |
Time |
08:37 |
Rev Time |
0.66 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-11-07 00:00:00 | REVISION APPROVED,PES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-14 |
Time |
17:32 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-11-14 |
Time |
17:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2001-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-12-08 |
Time |
08:02 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-08 00:00:00 | TRUSSES | | | DENIED | | | | | | 1) THE TRUSS LAYOUT REQUIRES THE WET | | | SIGNATURE, EMBOSSED SEAL AND DATE OF THE | | | TRUSS ENGINEER,AS WELL AS, HIS TITLE | | | BLOCK. THE TRUSS LAYOUT AND DRAWINGS | | | MUST BE REVIEWED BY THE DESIGNER OF | | | RECORD OF THE STRUCTURE AND HIS APPROVAL | | | MUST BE ACKNOWLEGED BY HIS SIGNATURE ON | | | THE LAYOUT. | | | | | | 2) INDICATE THE CONNECTORS TO BE USED | | | ON TRUSS K2 AT COVERED LANAI (UPLIFT | | | 1528# & 1483#) WHICH IS NOT INDICATED ON | | | SHEET A5 (ROOF PLAN). | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2001-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-12-08 |
Time |
07:20 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-08 00:00:00 | ************BUILDING PROVISO************ | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - FIXED GLASS WINDOWS | | | - SLIDING GLASS DOORS | | | - FRENCH DOORS | | | - STRUCTURAL MULLIONS | | | MUST BE SUBMITTED FOR APPROVAL PRIOR TO | | | INSTALLATION AND MUST MEET OR EXCEED | | | WINDLOAD REQUIREMENTS OF ASSEMBLY IN | | | WHICH THEY ARE TO BE INSTALLED. | | | | | | 3) SUBMIT CURRENT PRODUCT APPROVALS FOR | | | SINGLE HUNG WINDOWS, GLASS BLOCK AND | | | ROOF TILES FOR REVIEW PRIOR TO | | | INSTALLATION. THE ONES THAT WERE | | | SUBMITTED HAD EXPIRED PRIOR TO 10/15/01, | | | WHICH IS THE DATE APPLICATION FOR PERMIT | | | WAS SUBMITTED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-11-14 |
Time |
15:29 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-10-24 |
Time |
10:12 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-30 00:00:00 | SETBACKS INCORRECT |
|
|
|