Plan Review Details - Permit 01100752
Plan Review Stops For Permit 01100752
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-03-27 Cont ID  
Sent By jwitmer Date 2002-03-27 Time 11:18 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-03-27 00:00:00PROVISO: AS FROM THE ISSUANCE OF THE
 BUILDING PERMIT, PROVIDE PRODUCT
 APPROVALS, DOORS, ROLL-UP DOOR AND
 ROOFING MATERIALS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-02-05 Cont ID  
Sent By jwitmer Date 2002-02-05 Time 09:05 Rev Time 2.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-02-05 00:00:00TRUSS SHOP DRAWINGS, REVISIONSJW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-11-28 Cont ID  
Sent By jwitmer Date 2001-11-28 Time 14:36 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-11-01 Cont ID  
Sent By jwitmer Date 2001-11-01 Time 19:21 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-11-01 00:00:00PROVISO: PROVIDE ROOFING PRODUCT APPROV-
 AL REPORT BEFORE ROOF FRAMING INSP.
 SUBMIT EITHER SBCCI OR DADE COUNTY
 PRODUCT ACCEPTANCE REPORT BEFOR ROOF
 FRAMING INSPECTION.
  
 BUILDING PLAN REVIEW
 JIM WWITMER
 (561)659-8096 X8412

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2002-03-21 Cont ID  
Sent By dpalmer Date 2002-03-21 Time 10:04 Rev Time 0.00
Received By dpalmer Date 2002-03-21 Time 10:04 Sent To  
Notes
2002-03-21 00:00:00NOTHING SUBMITTED FOR ELECTRICAL REVIEW.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2002-01-31 Cont ID  
Sent By dpalmer Date 2002-01-31 Time 06:35 Rev Time 0.00
Received By dpalmer Date 2002-01-31 Time 06:35 Sent To  
Notes
2002-01-31 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE NOTE TWO DIFFERENT SETS
 WERE SUBMITTED? PLEASE CLARFIY WHICH ONE
 IS FOR THE REVISION, OR IS THERE TWO
 SEPARATE BLDGS?
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-11-19 Cont ID  
Sent By dpalmer Date 2001-11-19 Time 20:49 Rev Time 0.00
Received By dpalmer Date 2001-11-19 Time 20:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-10-25 Cont ID  
Sent By dpalmer Date 2001-10-25 Time 07:10 Rev Time 0.00
Received By dpalmer Date 2001-10-25 Time 07:10 Sent To  
Notes
2001-10-25 00:00:00******************** UNSAT *************
  
  
 1)NOTE: PLEASE NOTE THAT RISER SHOWS AN
 EQUIPMENT GOROUNDING CONDUCTOR BEING
 INSTALLED BETWEEN METER AND MAIN BKR
 PANEL? PLEASE NOTE THAT THIS IS
 PARALLELING THE NEUTRAL.
  
 2)NOTE: PLEASE NOTE THAT BLDG/FOOTER
 STEEL IS REQ`D TO BE PART OF THE
 GROUNDING ELECTRODE SYSTEM. 250-50
  
 3)NOTE: PLEASE NOTE AND CLARIFY THE
 SWITCHING METHOD FOR LIGHTS IN BATHROOMS
 ?? PLEASE NOTE THAT PLANS SHOWS S3.
 NOTE THAT IF IN ONE BATH, THEN PERSON IN
 OTHER BATH CAN TURN LIGHTS OFF?
 PLEASE NOTE THAT THIS MAY BE A PROBLEM
 WITH SAFETY.
  
  
 4)NOTE: PLEASE NOTE THAT CONTINUOUS
 LOADS NEED TO BE SHOWN AT 125%.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-02-01 Cont ID  
Sent By mcarsill Date 2002-02-01 Time 10:50 Rev Time 0.00
Received By mcarsill Date 2002-02-01 Time 10:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-11-28 Cont ID  
Sent By mcarsill Date 2001-11-28 Time 13:55 Rev Time 0.00
Received By mcarsill Date 2001-11-28 Time 13:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-10-25 Cont ID  
Sent By mcarsill Date 2001-10-25 Time 12:50 Rev Time 0.00
Received By mcarsill Date 2001-10-25 Time 12:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-11-28 Cont ID  
Sent By jwitmer Date 2001-11-28 Time 14:35 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2002-04-22 Cont ID  
Sent By kstevens Date 2002-04-22 Time 17:59 Rev Time 0.00
Received By kstevens Date 2002-04-22 Time 17:59 Sent To  
Notes
2002-04-22 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) ALL REVISIONS SUBMITTED FOR SIGNED
 AND SEALED PLANS SHALL BE SIGNED AND
 SEALED BY ARCHITECT OF RECORD.
  
 2) REVISION SAYS INDIRECT FOR ICE MACH-
 INE, BUT SHOWS DIRECT WASTE. ALL INDIR-
 ECT WASTE SHALL DRAIN INTO A FLOOR SINK.
 PLEASE SUBMIT REVISION SHOWING AN APPRO-
 VED INDIRECT WASTE RECEPTOR.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-11-20 Cont ID  
Sent By kstevens Date 2001-11-20 Time 14:44 Rev Time 1.00
Received By kstevens Date 2001-11-20 Time 14:44 Sent To  
Notes
2001-11-20 00:00:00PASSED/PROVISO
  
 #' 2, 5 & 6 DRINKING FOUNTAINS ONLY.
 3" VTR REQUIRED FOR EACH STATION.
 RESTROOMS NOT TO SCALE - FIELD VERIFY
 MEASUREMENTS.
 ...KSTEVENS

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-11-02 Cont ID  
Sent By kstevens Date 2001-11-02 Time 11:46 Rev Time 1.25
Received By kstevens Date 2001-11-02 Time 11:46 Sent To  
Notes
2001-11-02 00:00:00DENIED
 REFERENCES: SPC-94 - FACBC-97
  
 1) COVER SHEET NOTES SHOW (2),(5) & (6)
 AS COMFORT STATIONS. NO RESTROOM SHOWN
 FOR (2) OR (6), BUT NOTE THERE IS WATER
 AND SEWER RUN TO THESE COMFORT STATIONS.
 PLEASE CLAIRFY.
 2) COMFORT STATION (5) NOT SHOWN ON PAGE
 1 AS INDICATED ON COVER SHEET. PLEASE
 INDICATE WHAT SHEET THIS STATION WILL BE
 SHOWN ON.
 3) PAGE A-1, FLOOR PLAN. RESTROOMS ARE
 NOT LARGE ENOUGH FOR 5' TURNING RADIUS
 REQUIRED PER FACBC SEC 4.22.3 & 4.2.3
 MINIMUM DEPTH OF TOILET ROOM TO BE 7'5"
 4) PAGE A-1 HDCP W/C TO COMPLY WITH SEC
 4.16 OF FACBC-97 PLEASE SHOW DETAILS.
 5) PAGE A-1 HDCP LAV TO COMPLY WITH SEC
 4.19 OF FACBC-97 PLEASE SHOW DETAILS.
 6) PAGE A-1 HDCP DRINKING FOUNTAIN TO
 COMPLY WITH SEC 4.15 OF FACBC-97 PLEASE
 SHOW DETAILS. IF SINGLE DRINKING FOUNT-
 AIN IS USED, PROVISIONS SHALL BE PROVID-
 ED FOR THOSE WHO HAVE DIFFICULTY BENDING
 OR STOOPING PER SEC 4.1.3(10) FACBC-97
 7) PAGE A-2 WATER SUPPLY RISER DIAGRAM.
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 PER MANUFACTURE INSTALLATION INSTRUCTION
 AND WH-PDI 201, CLOSE TO FIXTURES NOT ON
 HIGH UP AS SHOWN. THESE ARRESTORS DO NOT
 REQUIRE ACCESS PANELS.
 8) PAGE A-2 SANITARY RISER DIAGRAM. TRAP
 PRIMERS ARE REQUIRED ON FLOOR DRAINS IN
 PUBLIC RESTROOMS PER SPC SEC 409.4.1.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-28 Cont ID  
Sent By jwitmer Date 2001-11-28 Time 14:34 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-11-28 00:00:00ZONING OK S GRAHAM SEE APPLICATION