Plan Review Details - Permit 01100681
Plan Review Stops For Permit 01100681
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-02-11 Cont ID  
Sent By jwitmer Date 2002-02-11 Time 11:50 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-01-24 Cont ID  
Sent By jwitmer Date 2002-01-24 Time 18:02 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-24 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01100681
 217 BUTLER STREET
  
 1)- CHANGE OF OCCUPANCY, THE CONTRACTOR
 SHALL HAVE THE PLANS REVIEWED BY PALM
 BEACH COUNTY TO ASERTAIN IF COUNTY
 IMPACT FEES ARE TO BE ASSESSED.
  
 2) SHEET A-3 INDICATES NEW WINDOWS AS
 WELL AS STORM SHUTTERS PLEASE PROVIDE
 PRODUCT ACCEPTANCE REPORTS, EITHER
 SBCCI OR DADE COUNTY REPORTS ARE ACCEPT-
 ABLE.
  
 3) FL. ACCESSIBILITY CODE 4.13.6
 MANEUVERING AT DOORS, THE GROUND FLOOR
 OFFICE BATH DOOR REQUIRES A MINIMUM OF
 12" ON THE LATCH PUSH SIDE OF THE DOOR.
  
 4) IS THE AREA DIRECTLY IN FRONT OF THE
 OFFICE DOOR IS THIS FLOOR LEVEL WITH
 THE INTERIOR FLOOR OR IS THERE A STEP?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-12-04 Cont ID  
Sent By lmartine Date 2001-12-04 Time 09:09 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2001-12-04 00:00:00SEE PREVIOUS REVIEW COMMENTS
  
  
 L. MARTINEZ
 659 8096
 #8456

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-09 Cont ID  
Sent By hpiskura Date 2001-11-09 Time 14:08 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-11-09 00:00:00THE CHANGE IN OCCUPANCY USE IS SUBJECT
 TO IMPACT FEES COLLECTED BY THE COUNTY
 FOR THE CITY.THE PERMIT PLANS MUST BE
 REVIEWED AND STAMPED BY THAT OFFICE.
 CALL 561-233-5025 FOR MORE INFORMATION.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-01-30 Cont ID  
Sent By dpalmer Date 2002-01-30 Time 18:21 Rev Time 0.00
Received By dpalmer Date 2002-01-30 Time 18:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-11-28 Cont ID  
Sent By dpalmer Date 2001-11-28 Time 22:34 Rev Time 0.00
Received By dpalmer Date 2001-11-28 Time 22:34 Sent To  
Notes
2001-11-28 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE NOTE THAT NOT ALL NOTES
 FROM FIRST REVIEW WERE ADDRESSED.
  
 2)NOTE: PLEASE NOTE THE BATH(S) GFI
 CIRCUTI IS STILL SHOWN WITH SMOKE DETEC.
 PLEASE LIST PER 210-11-C-3 20A,#12
  
 3)NOTE: PLEASE NOTE THE LOAD CALCUALTION
 -S SUBMTTED DO NOT INCLUDE LOADS ON
 EXISTING 6 UNITS? PLEASE ALSO NOTE
 ALL CONTINUOUS LOADS STILL NEED TO BE
 SHOWN AT 125%.
  
 4)NOTE: PLEASE NOTE, NOTE # 4 SECOND
 FLOOR DOOR? WHERE DOES THIS GO?
 MEANS OF EGRESS LT FOR FIRST FLOOR DOOR.
 210-70
  
 5)NOTE: PLEASE NOTE THAT 8 1/2X 11`S
 SUBMITTED BY ARCH BEING SIGNED,DATED AND
 SEALED, MUST CONTAIN A TITLE BLOCK PER
 61G-14.004.
  
 6)NOTE: PLEASE CLARIFY PANEL SHOWN AS
 EXISTING,NEW, SUB PANEL? WHICH ONE?
 FOR PANEL FOR OFFICE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-10-30 Cont ID  
Sent By dpalmer Date 2001-10-30 Time 22:27 Rev Time 0.00
Received By dpalmer Date 2001-10-30 Time 22:22 Sent To  
Notes
2001-10-30 00:00:00******************* UNSAT **************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2)NOTE: PLEASE NOTE THAT THE LOAD
 CALCULATIONS FRO COMMERCIAL AREA NEEDS
 TO BE SHOWN. ALL CONTINUOUS LOADS AT
 125%/ LARGEST MOTOR ETC.
  
 3)NOTE: PLEASE SUBMIT AN ELECTRICAL
 RISER DIAGRAM SHOWING FEED TO NEW PANEL?
 FROM EXISTING? HOW IS EXISTING FED?
 CONDUCTOR SIZES, CONDUITS, GROUNDING
 215-5/250-122/310-16
 NOTES ON PLANS MENTION THAT ELECTRICAN
 IS SUBMIT ALL THIS INFORMATION THAT
 IS NEEDED. THIS IS REQ`D AT THIS TIME
 FOR PLAN REVIEW BY THE ARCH/ENGINEER
 OF RECORD.
  
 4)NOTE: PLEASE CLARIFY DOOR SHOWN FROM
 SECOND FLOOR TO ?? MEANS OF EGRESS?
 210-70
  
 5) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 6)NOTE: PLANS ONLY SHOW ONE SMALL APPL
 CIRCUIT? 210-52B
  
 7)NOTE: PLEASE NOTE THAT ALL CIRCUIT #`S
 ARE TO BE SHOWN ON PLANS AND CORRELATE
 WITH SUBMITTED PANEL SCHEDULES.
 COMMERICAL AREA.
  
 8)NOTE: PLEASE NOTE MISSING SIGN CIRCUIT
 PER 600-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-11-09 Cont ID  
Sent By hpiskura Date 2001-11-09 Time 14:11 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-01-17 Cont ID  
Sent By mcarsill Date 2002-01-17 Time 17:36 Rev Time 0.00
Received By mcarsill Date 2002-01-17 Time 17:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-11-29 Cont ID  
Sent By mcarsill Date 2001-11-29 Time 09:18 Rev Time 0.00
Received By mcarsill Date 2001-11-29 Time 09:18 Sent To  
Notes
2001-11-29 00:00:00PREVIOUS PLAN REVIEW COMMENTS NOT
 ADDRESSED ON THE PLANS THAT WERE
 RE-SUBMITTED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-11-01 Cont ID  
Sent By mcarsill Date 2001-11-01 Time 13:49 Rev Time 0.00
Received By mcarsill Date 2001-11-01 Time 13:49 Sent To  
Notes
2001-11-01 00:00:001) PLEASE INDICATE ON PLANS, THE
 DIMENSIONS OF THE NEW EGRESS WINDOWS
 PLANNED FOR THE FIRST FLOOR. ALSO
 PROVIDE MAXIMUM HEIGHTS OF WINDOW
 SILLS FOR THESE LOCATIONS.
 2) ELECTRIC POWERED SMOKE DETECTORS
 ARE REQUIRED. WHEN SOUNDING, THESE
 DEVICES ARE TO BE HEARD IN THE
 SLEEPING ROOMS OF THAT UNIT.
 3) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR NEW
 APARTMENT.
 4) PLEASE INDICATE OCCUPANT LOAD FOR
 NEW APARTMENT.
 5) PLEASE PROVIDE MORE DETAILS ON SPIRAL
 STAIR.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2002-01-30 Cont ID  
Sent By pkrauss Date 2002-01-30 Time 10:21 Rev Time 0.25
Received By pkrauss Date 2002-01-30 Time 10:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-10-30 Cont ID  
Sent By pkrauss Date 2001-10-30 Time 09:46 Rev Time 0.45
Received By pkrauss Date 2001-10-30 Time 09:46 Sent To  
Notes
2001-10-30 00:00:00 
  
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-01-31 Cont ID  
Sent By kstevens Date 2002-01-31 Time 15:55 Rev Time 0.75
Received By kstevens Date 2002-01-31 Time 15:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-12-03 Cont ID  
Sent By kstevens Date 2001-12-03 Time 18:06 Rev Time 1.00
Received By kstevens Date 2001-12-03 Time 18:06 Sent To  
Notes
2001-12-03 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) SANITARY RISER DIAGRAM STILL DOES NOT
 MEET CODE REQUIREMENTS. PLEASE WET VENT
 EACH W/C AND RUN KITCHEN TO BLDG DRAIN
 NOT INTO LAV STACK.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-11-02 Cont ID  
Sent By kstevens Date 2001-11-02 Time 17:45 Rev Time 0.75
Received By kstevens Date 2001-11-02 Time 17:45 Sent To  
Notes
2001-11-02 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) PAGE A-5 CONVERTED PLUMBING PLAN.
 PLEASE SPECIFY IF SANITARY PIPING WILL
 BE PVC OR CAST IRON. MUST BE ALL ONE OR
 THE OTHER FOR FIRE PENETRATION APPROVAL
 2) PAGE A-5 PLUMBING RISER NOT TO CODE.
 1ST W/C NOT VENTED PROPERLY AND KITCHEN
 FROM 2ND FLOOR TO DRAIN INTO BLDG DRAIN
 NOT BRANCH LINE. SPC SEC 914.1 - 911.4
 3) PLEASE SUBMIT A WATER RISER DIAGRAM
 4) PAGE A-5 HDCP W/C DETAIL. W/C TO BE
 1'6" TO C/L OFF WALL AND 17" TO 19" TO
 TOILET SEAT ABOVE FINISH FLOOR. PLEASE
 SHOW DETAIL.
 5) PAGE A-5 PLUMBING NOTES #14. AIR
 CHAMBERS DO NOT WORK, AND IF INSTALLED
 SHAL COMPLY WITH SPC SEC 607.8.3 AND BE
 ACCESSIBLE AND RECHARGEABLE PER WH-PDI
 201. WATER HAMMER ARRESTORS IF USED
 SHALL BE LOCATED AND SIZED PER MANUFACT-
 URE INSTALLATIION INSTRUCTIONS AND WH-
 PDI 201, CLOSE TO FIXTURE.
 6) PAGE A-4, WATER HEATER SHALL COMPLY
 WITH MODEL COUNTYWIDE AMENDMENTS TO SPC
 SEC 507.8.1 (SAFETY PAN) AND SHALL HAVE
 A MINIMUM 1" PAN DRAIN. ALSO P/T RELIEF
 VALVE TO BE FULL SIZE. BOTH TO DRAIN TO
 AN OBSERVABLE POINT OUTSIDE THE BLDG. &
 SHALL BE TURNED DOWN WITHIN 6" OF GROUND
 LEVEL. SEC 507.6
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-17 Cont ID  
Sent By sgraham Date 2001-10-17 Time 10:00 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***