| Plan Review Stops For Permit 01100681 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-02-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-02-11 |
Time |
11:50 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2002-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-01-24 |
Time |
18:02 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-01-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01100681 | | | 217 BUTLER STREET | | | | | | 1)- CHANGE OF OCCUPANCY, THE CONTRACTOR | | | SHALL HAVE THE PLANS REVIEWED BY PALM | | | BEACH COUNTY TO ASERTAIN IF COUNTY | | | IMPACT FEES ARE TO BE ASSESSED. | | | | | | 2) SHEET A-3 INDICATES NEW WINDOWS AS | | | WELL AS STORM SHUTTERS PLEASE PROVIDE | | | PRODUCT ACCEPTANCE REPORTS, EITHER | | | SBCCI OR DADE COUNTY REPORTS ARE ACCEPT- | | | ABLE. | | | | | | 3) FL. ACCESSIBILITY CODE 4.13.6 | | | MANEUVERING AT DOORS, THE GROUND FLOOR | | | OFFICE BATH DOOR REQUIRES A MINIMUM OF | | | 12" ON THE LATCH PUSH SIDE OF THE DOOR. | | | | | | 4) IS THE AREA DIRECTLY IN FRONT OF THE | | | OFFICE DOOR IS THIS FLOOR LEVEL WITH | | | THE INTERIOR FLOOR OR IS THERE A STEP? | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096 X8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-12-04 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-12-04 |
Time |
09:09 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-04 00:00:00 | SEE PREVIOUS REVIEW COMMENTS | | | | | | | | | L. MARTINEZ | | | 659 8096 | | | #8456 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-11-09 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-11-09 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-09 00:00:00 | THE CHANGE IN OCCUPANCY USE IS SUBJECT | | | TO IMPACT FEES COLLECTED BY THE COUNTY | | | FOR THE CITY.THE PERMIT PLANS MUST BE | | | REVIEWED AND STAMPED BY THAT OFFICE. | | | CALL 561-233-5025 FOR MORE INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-30 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-01-30 |
Time |
18:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-28 |
Time |
22:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-28 |
Time |
22:34 |
Sent To |
|
|
| Notes |
| 2001-11-28 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE NOTE THAT NOT ALL NOTES | | | FROM FIRST REVIEW WERE ADDRESSED. | | | | | | 2)NOTE: PLEASE NOTE THE BATH(S) GFI | | | CIRCUTI IS STILL SHOWN WITH SMOKE DETEC. | | | PLEASE LIST PER 210-11-C-3 20A,#12 | | | | | | 3)NOTE: PLEASE NOTE THE LOAD CALCUALTION | | | -S SUBMTTED DO NOT INCLUDE LOADS ON | | | EXISTING 6 UNITS? PLEASE ALSO NOTE | | | ALL CONTINUOUS LOADS STILL NEED TO BE | | | SHOWN AT 125%. | | | | | | 4)NOTE: PLEASE NOTE, NOTE # 4 SECOND | | | FLOOR DOOR? WHERE DOES THIS GO? | | | MEANS OF EGRESS LT FOR FIRST FLOOR DOOR. | | | 210-70 | | | | | | 5)NOTE: PLEASE NOTE THAT 8 1/2X 11`S | | | SUBMITTED BY ARCH BEING SIGNED,DATED AND | | | SEALED, MUST CONTAIN A TITLE BLOCK PER | | | 61G-14.004. | | | | | | 6)NOTE: PLEASE CLARIFY PANEL SHOWN AS | | | EXISTING,NEW, SUB PANEL? WHICH ONE? | | | FOR PANEL FOR OFFICE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-30 |
Time |
22:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-30 |
Time |
22:22 |
Sent To |
|
|
| Notes |
| 2001-10-30 00:00:00 | ******************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2)NOTE: PLEASE NOTE THAT THE LOAD | | | CALCULATIONS FRO COMMERCIAL AREA NEEDS | | | TO BE SHOWN. ALL CONTINUOUS LOADS AT | | | 125%/ LARGEST MOTOR ETC. | | | | | | 3)NOTE: PLEASE SUBMIT AN ELECTRICAL | | | RISER DIAGRAM SHOWING FEED TO NEW PANEL? | | | FROM EXISTING? HOW IS EXISTING FED? | | | CONDUCTOR SIZES, CONDUITS, GROUNDING | | | 215-5/250-122/310-16 | | | NOTES ON PLANS MENTION THAT ELECTRICAN | | | IS SUBMIT ALL THIS INFORMATION THAT | | | IS NEEDED. THIS IS REQ`D AT THIS TIME | | | FOR PLAN REVIEW BY THE ARCH/ENGINEER | | | OF RECORD. | | | | | | 4)NOTE: PLEASE CLARIFY DOOR SHOWN FROM | | | SECOND FLOOR TO ?? MEANS OF EGRESS? | | | 210-70 | | | | | | 5) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | 6)NOTE: PLANS ONLY SHOW ONE SMALL APPL | | | CIRCUIT? 210-52B | | | | | | 7)NOTE: PLEASE NOTE THAT ALL CIRCUIT #`S | | | ARE TO BE SHOWN ON PLANS AND CORRELATE | | | WITH SUBMITTED PANEL SCHEDULES. | | | COMMERICAL AREA. | | | | | | 8)NOTE: PLEASE NOTE MISSING SIGN CIRCUIT | | | PER 600-5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-11-09 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-11-09 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2002-01-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-01-17 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-01-17 |
Time |
17:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-11-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-29 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-29 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2001-11-29 00:00:00 | PREVIOUS PLAN REVIEW COMMENTS NOT | | | ADDRESSED ON THE PLANS THAT WERE | | | RE-SUBMITTED. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-11-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-01 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-01 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2001-11-01 00:00:00 | 1) PLEASE INDICATE ON PLANS, THE | | | DIMENSIONS OF THE NEW EGRESS WINDOWS | | | PLANNED FOR THE FIRST FLOOR. ALSO | | | PROVIDE MAXIMUM HEIGHTS OF WINDOW | | | SILLS FOR THESE LOCATIONS. | | | 2) ELECTRIC POWERED SMOKE DETECTORS | | | ARE REQUIRED. WHEN SOUNDING, THESE | | | DEVICES ARE TO BE HEARD IN THE | | | SLEEPING ROOMS OF THAT UNIT. | | | 3) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR NEW | | | APARTMENT. | | | 4) PLEASE INDICATE OCCUPANT LOAD FOR | | | NEW APARTMENT. | | | 5) PLEASE PROVIDE MORE DETAILS ON SPIRAL | | | STAIR. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2002-01-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-30 |
Time |
10:21 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2002-01-30 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-30 |
Time |
09:46 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-10-30 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2001-10-30 00:00:00 | | | | | | | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-01-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-01-31 |
Time |
15:55 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2002-01-31 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-12-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-03 |
Time |
18:06 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2001-12-03 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2001-12-03 00:00:00 | DENIED | | | REFERENCE: SPC-94-FACBC-97 | | | | | | 1) SANITARY RISER DIAGRAM STILL DOES NOT | | | MEET CODE REQUIREMENTS. PLEASE WET VENT | | | EACH W/C AND RUN KITCHEN TO BLDG DRAIN | | | NOT INTO LAV STACK. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-11-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-02 |
Time |
17:45 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2001-11-02 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2001-11-02 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) PAGE A-5 CONVERTED PLUMBING PLAN. | | | PLEASE SPECIFY IF SANITARY PIPING WILL | | | BE PVC OR CAST IRON. MUST BE ALL ONE OR | | | THE OTHER FOR FIRE PENETRATION APPROVAL | | | 2) PAGE A-5 PLUMBING RISER NOT TO CODE. | | | 1ST W/C NOT VENTED PROPERLY AND KITCHEN | | | FROM 2ND FLOOR TO DRAIN INTO BLDG DRAIN | | | NOT BRANCH LINE. SPC SEC 914.1 - 911.4 | | | 3) PLEASE SUBMIT A WATER RISER DIAGRAM | | | 4) PAGE A-5 HDCP W/C DETAIL. W/C TO BE | | | 1'6" TO C/L OFF WALL AND 17" TO 19" TO | | | TOILET SEAT ABOVE FINISH FLOOR. PLEASE | | | SHOW DETAIL. | | | 5) PAGE A-5 PLUMBING NOTES #14. AIR | | | CHAMBERS DO NOT WORK, AND IF INSTALLED | | | SHAL COMPLY WITH SPC SEC 607.8.3 AND BE | | | ACCESSIBLE AND RECHARGEABLE PER WH-PDI | | | 201. WATER HAMMER ARRESTORS IF USED | | | SHALL BE LOCATED AND SIZED PER MANUFACT- | | | URE INSTALLATIION INSTRUCTIONS AND WH- | | | PDI 201, CLOSE TO FIXTURE. | | | 6) PAGE A-4, WATER HEATER SHALL COMPLY | | | WITH MODEL COUNTYWIDE AMENDMENTS TO SPC | | | SEC 507.8.1 (SAFETY PAN) AND SHALL HAVE | | | A MINIMUM 1" PAN DRAIN. ALSO P/T RELIEF | | | VALVE TO BE FULL SIZE. BOTH TO DRAIN TO | | | AN OBSERVABLE POINT OUTSIDE THE BLDG. & | | | SHALL BE TURNED DOWN WITHIN 6" OF GROUND | | | LEVEL. SEC 507.6 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-10-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-10-17 |
Time |
10:00 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|