Plan Review Details - Permit 01100589
Plan Review Stops For Permit 01100589
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-11-20 Cont ID  
Sent By jwitmer Date 2001-11-20 Time 14:52 Rev Time 1.00
Received By jwitmer Date 2001-11-20 Time 14:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-30 Cont ID  
Sent By jwitmer Date 2001-10-30 Time 11:51 Rev Time 2.00
Received By jwitmer Date 2001-10-30 Time 08:47 Sent To  
Notes
2001-10-30 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01100589
 777 S FLAGLER /1102 7TH FL/12 FL
 CATALFUMO
 624-9697X256
  
 1)- ADDITIONAL INFO REQUIRED, THE LOCA-
 TION OF THE REFIGERANT PIPING THROUGH
 THE VARIOUS FLOORS? EXAMPLE, IS THIS LO-
 CATED IN A STAIRWELL, COMMON AREAS OR
 TENANT SPACES.
  
 2)- THE PLANS DEPICT THE REFRIGARANT PIP
 ING TO BE INSULATED WITH 3/4 " ARMAFLEX.
 SBC 705.4.3 INSULATION AND COVERINGS ON
 THE PENETRATING ITEM SHALL NOT PENETRATE
 THE ASSEMBLY UNLESS THE SPECIFIC MATER-
 IAL USED HAS BEEN TESTED AS PART OF THE
 ASSEMBLY IN ACCORDANCE WITH 705.6
  
 3)- SBC705.6 ALL PENETRATIONS OF A FLOOR
 FLOOR/ CEILING ASSEMBLY OR THE CEILING
 MEMBER OF A ROOF/CEILING ASSEMBLY SHALL
 BE IN ACCORDANCE WITH 705.2.PROVIDE
 MANUFACTURES SPEC ON THE FIRE STOPPING
 MATERIAL AND THE RATING.TABLE 600 /
 TYPE I BUILD. 2 HR FLOOR RATING/SPRINK-
 LERED.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X8412

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-24 Cont ID  
Sent By dpalmer Date 2001-10-24 Time 23:02 Rev Time 0.00
Received By dpalmer Date 2001-10-24 Time 23:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-10-22 Cont ID  
Sent By mcarsill Date 2001-10-22 Time 17:06 Rev Time 0.00
Received By mcarsill Date 2001-10-22 Time 17:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-10-26 Cont ID  
Sent By pkrauss Date 2001-10-26 Time 08:25 Rev Time 0.40
Received By pkrauss Date 2001-10-26 Time 08:09 Sent To  
Notes
2001-10-26 00:00:00 
 LOCATION OF CONDENSER UNIT IS IN A MECH
 ROOM WITH OTHER CONDENSERS WITH A LOUVRE
 TO THE OUTSIDE.NOT A CONDITIONED
 SPACE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.