Plan Review Details - Permit 01091712
Plan Review Stops For Permit 01091712
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-04-19 Cont ID  
Sent By lmartine Date 2002-04-19 Time 09:09 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-03-11 Cont ID  
Sent By lmartine Date 2002-03-11 Time 15:46 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2002-03-11 00:00:00TRUSS ENGINEERING
 -----------------
  
 TRUSS DESIGN SHALL COMPLY WITH
 BUIDING DESIGN.
  
 TRUSSES ASCE-93
 BUILDINGASCE-98
  
 L.MARTINEZ
 659-8096
 #8456

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-21 Cont ID  
Sent By lmartine Date 2001-12-21 Time 14:39 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2001-12-21 00:00:00BUILDING COMMENTS
  
  
 PROVISO
 -------
  
 COUNTY IMPACT FEES SHALL BE PAID.
  
 A SEPERATE PERMIT WILL BE REQUIRED FOR
 THE WINDOWS, DOORS AND ROOF.
  
  
  
 LUIS MARTINEZ
 659-8096
 #8456

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-16 Cont ID  
Sent By lmartine Date 2001-11-16 Time 09:27 Rev Time 10.00
Received By lmartine Date   Time   Sent To  
Notes
2001-11-16 00:00:00 
 BUILDING COMMENTS
 -----------------
  
 1]
 SUBMIT A CURRENT SIGNED AND SEALED
 PROPERTY SURVEY. VERIFY FLOOD ZONE.
 2]
 SHEET A2.0, WEST ELEVATION SHOWS GLASS
 BLOCK WITHIN THE BOND BEAM.
 3]
 SECTION 4.13.6, FL. ACC. CODE REQUIRES
 MINIMUM 18" CLEAR ON PULL SIDE OF DOORS
 E01, AND 03.
 4]
 SUBMIT PRODUCT TEST REPORTS FOR ROOF
 COVER, WINDOWS, DOORS, AND SIDING.
 5]
 A RECORDED NOTICE OF COMMENCEMENT IS
 REQUIRED.
 6]
 COUNTY IMPACT FEES AND CITY TRAINING
 FEES ARE DUE.
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 659-8096
 #8456

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-12-05 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 20:26 Rev Time 0.00
Received By dpalmer Date 2001-12-05 Time 20:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-10-30 Cont ID  
Sent By dpalmer Date 2001-10-30 Time 20:29 Rev Time 0.00
Received By dpalmer Date 2001-10-30 Time 20:29 Sent To  
Notes
2001-10-30 00:00:00******************* UNSAT ************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
 SUBMITTED FOR PANELS BUT NOT FOR MAIN.
  
 2)NOTE: PLEASE NOTE THAT THE PLANS DO
 NOT SHOW ANY LOAD CALCULATIONS? ALSO
 ALL CONTINOUS LOADS ARE TO BE SHOWN AT
 125% . 215-5/215-2-3/ 230-42 ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-11-13 Cont ID  
Sent By lmartine Date 2001-11-13 Time 14:25 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-12-26 Cont ID  
Sent By mcarsill Date 2001-12-26 Time 13:36 Rev Time 0.00
Received By mcarsill Date 2001-12-26 Time 13:36 Sent To  
Notes
2001-12-26 00:00:00ON 12.24.01 RECEIVED A LETTER FROM
 TIMOTHY F. HULLIHAN INDICATING THAT
 THE SINGLE EXIT WILL BE ONE HOUR FIRE
 PROTECTED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-12-10 Cont ID  
Sent By mcarsill Date 2001-12-10 Time 08:59 Rev Time 0.00
Received By mcarsill Date 2001-12-10 Time 08:59 Sent To  
Notes
2001-12-10 00:00:001) PLEASE INDICATE ON THE PLANS THAT
 THE STAIR WILL BE ENCLOSED BY A ONE
 HOUR FIRE RATING. SINGLE EXIT RATIONALE
 IF BEING USED MUST COMPLY WITH
 SECTION 5-1.3 WHICH REQUIRES THAT
 EXIT STAIRS MUST BE RATED BY AT LEAST
 ONE HOUR WHEN IT CONNECTS THREE STORIES
 OR LESS. THIS WOULD INCLUDE DOORS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-10-31 Cont ID  
Sent By mcarsill Date 2001-10-31 Time 13:06 Rev Time 0.00
Received By mcarsill Date 2001-10-31 Time 13:06 Sent To  
Notes
2001-10-31 00:00:001) A SINGLE MEANS OF EGRESS IS SHOWN
 FROM THE SECOND WHICH IS NOT
 PROTECTED. THE FIRE CODE REQUIRES
 AT LEAST TWO MEANS OF EGRESS SHALL BE
 PROVIDED AT EVERY LEVEL. THE TWO
 EXCEPTIONS ARE AS FOLLOWS:
  
 # 1, OCCUPANT LOAD OF LESS THAN 100
 PERSONS, DIRECT ACCESS TO THE OUTSIDE,
 TOTAL TRAVEL DISTANCE LESS THAN 100
 FEET, AND COMPLETELY SEPARATED FROM
 OTHER PARTS OF THE BUILDING.
  
 # 2, BUILDING LESS THAN THREE STORIES,
 OCCUPANT LOAD LESS THAN 30 PERSONS,
 TRAVEL DISTANCE LESS THAN 100 FEET, AND
 EXIT IS ENCLOSED.
  
 UNPROTECTED VERTICAL OPENINGS ARE
 PERMITTED WITH THE FOLLOWING CONDITIONS:
 THE AREA IS LOW HAZARD OR ORDINARY
 HAZARD, THE LOWEST OR NEXT LEVEL IS
 THE STREET FLOOR, AREA IS OPEN AND
 UNOBSTRUCTED, AND EXIT CAPACITY CAN
 PROVIDE FOR ALL OCCUPANTS. THE OTHER
 EXCEPTION INDICATES CONNECTION WITH
 TWO FLOORS, THE OPENING IS NOT A
 REQUIRED MEANS OF EGRESS, OPENING IS
 NOT CONNECTED WITH STAIRWAYS OR
 CORRIDORS, AND A FIRE SPRINKLER SYSTEM
 IS PROVIDED.
  
 BUISNESS OCCUPANCIES ACCORDING TO THE
 FIRE CODE IS CONSIDERED AN ORDINARY
 HAZARD. (CONTENTS)
  
 THE CODE ALSO INDICATES THAT WHERE
 CHAPTERS 1-7 ARE DIFFERENT FROM 8-30,
 THE INFORMATION IN CHAPTERS 8-30
 SHALL APPLY.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-12-27 Cont ID  
Sent By ndenmark Date 2001-12-27 Time 14:22 Rev Time 0.50
Received By ndenmark Date 2001-12-27 Time 14:21 Sent To  
Notes
2001-12-27 00:00:00PROVISO:
 DUCT PENETRATING RATED STAIR CEILING
 SHALL BE PROTECTED PER 1997 SMC 610.2
 PROVIDE DETAIL PRIOR TO INSPECTION

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-12-14 Cont ID  
Sent By pkrauss Date 2001-12-14 Time 12:35 Rev Time 0.45
Received By pkrauss Date 2001-12-14 Time 12:26 Sent To  
Notes
2001-12-14 00:00:00*******************PROVISO**************
  
 PLEASE NOTE, AS PER 1997 SBC 1006.1.3.1,
 PENETRATIONS INTO AND OPENINGS THROUGH
 A STAIRWAY ENCLOSURE ASSEMBLY ASRE
 PROHIBITED EXCEPT FOR REQUIRED EXIT
 DOORS, DUCTWORK & EQUIPMENT NECESSARU
 FOR INDEPENDENT STAIR PRESSURIZATION,
 SPRINKLER PIPING, STANDPIPES, AND
 ELECTRICAL CONDUIT SERVING THE STAIRWAY
 AND TERMINATING AT A STEEL BOX NOTY
 EXCEEDING 16 SQ INCHES.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-10-30 Cont ID  
Sent By pkrauss Date 2001-10-30 Time 13:20 Rev Time 1.20
Received By pkrauss Date 2001-10-30 Time 11:45 Sent To  
Notes
2001-10-30 00:00:00********************DENIED**************
  
 PLANS DO NOT SPECIFY THAT DUCTWORK IS
 IN A FIRE RATED ENCLOSURE.
  
 AS PER 1997 SMC 610.4, DUCTS PENETRATING
 ONLY ONE FLOOR MAY BE PROTECTED BY
 INSTALLING A LISTED FIRE DAMPER WHERE
 THE FLOOR IS PIERCED IN LIEU OF AN
 ENCLOSURE.
  
 OUTSIDE AIR CALCULATIONS ONLY INDICATE
 OFFICE AREAS AND STORAGE AREAS.THERE
 IS NO "STORAGE AREA" INDICATED ON THE
 FLOOR PLAN.ONLY 2 PRIVATE OFFICES, A
 WORKROOM AND CONSULATION.PLEASE
 REVISE OUTSIDE AIR CALCULATIONS TO
 REFLECT ALL AREAS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-02-04 Cont ID  
Sent By kstevens Date 2002-02-04 Time 13:53 Rev Time 0.75
Received By kstevens Date 2002-02-04 Time 13:53 Sent To  
Notes
2002-02-04 00:00:00REVISION PASSED - NO TOILET IN ROOM
 JUST SINK (LAV).

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-01-03 Cont ID  
Sent By kstevens Date 2002-01-03 Time 10:50 Rev Time 0.25
Received By kstevens Date 2002-01-03 Time 10:50 Sent To  
Notes
2002-01-03 00:00:00PASSED/PROVISO
 REFERENCE: SPC-94-FACBC-97
  
 REVISED PLANS SHOWING COMPLIANCE FOR
 ADAPTABLE BATHROOM REQUIRED BEFORE FIRST
 INSPECTION.
  
 KSTEVENS

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-12-20 Cont ID  
Sent By kstevens Date 2001-12-20 Time 13:50 Rev Time 0.50
Received By kstevens Date 2001-12-20 Time 13:50 Sent To  
Notes
2001-12-20 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) SHT A1.0 TOILET ROOM SHALL BE ADAPT-
 ABLE. 30" REQUIRED FROM C/L OF W/C TO
 C/L OF LAV. LAV TO BE 15" OFF WALL TO
 C/L. 63" FINISH OPENING REQUIRED FOR
 THESE REQUIREMENTS. 5' OPENING SHOWN.
  
 2) SHT A1.0 DOOR SHALL NOT SWING INTO
 CLEAR FLOOR SPACE OF LAV. DOOR MUST
 MUST SWING OUT OF TOILET ROOM. FACBC SEC
 422.2.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-11-02 Cont ID  
Sent By kstevens Date 2001-11-02 Time 18:59 Rev Time 1.00
Received By kstevens Date 2001-11-02 Time 18:58 Sent To  
Notes
2001-11-02 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) PAGE A1.0 TOILET ROOM. PLEASE SUBMIT
 DETAILS TO SHOW COMPLIANCE WITH FACBC-97
 SEC. 4.22. SHOW CLEAR FLOOR SPACE SEC
 4.22.3, W/C TO BE 1'6" OFF WALL, LAV TO
 BE 1'3" OFF WALL. SHOWER TO COMPLY WITH
 SEC 4.21 PLEASE SHOW DETAILS.
 2) PAGE A1.0 & PAGE P-1. FLOOR DRAIN
 REQUIRED IN TOILET ROOM AND SHALL BE
 EQUIPPED WITH A TRAP PRIMER. SPC SEC
 409.4.1.1
 3) PAGE P-2 GENERAL NOTES #16. AIR
 CHAMBERS SHALL COMPLY WITH SPC 607.8.3
 AND BE RECHARGEABLE AND ACCESSIBLE. ALSO
 THEY ARE A "QUICK FIX" AND WATER HAMMER
 ARRESTORS SHOULD BE USED. THEY SHALL BE
 SIZED AND LOCATED PER MANU. INSTALL. IN-
 STRUCTIONS AND WH-PDI 201, CLOSE TO FIX-
 TURE.
 4) PAGE P-1 KEYNOTES #'S 12 & 13. SEPAR-
 ATE PERMIT REQUIRED FOR GAS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-17 Cont ID  
Sent By sgraham Date 2001-10-17 Time 09:56 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***