| Plan Review Stops For Permit 01091473 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-10-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-10-18 |
Time |
13:47 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-10-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-22 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-22 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-10-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-01 |
Time |
22:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-01 |
Time |
22:38 |
Sent To |
|
|
| Notes |
| 2001-10-01 00:00:00 | ***************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT REQUIREMNETS | | | PER ART;517 NEED TO BE SHOWN ON PLANS. | | | | | | 2)NOTE: PLEASE NOTE THAT ALL NEW DEVICES | | | NEED TO HAVE BRANCH CIRCUIT #`S SHOWN | | | ON PLANS AND TO HAVE SUBMITTED PANEL | | | SCHEDULES. PLEASE SHOW ALL EXISTING | | | W/ AND "E". | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE QUESTIONS, PLEASE | | | CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-10-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-10-18 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-10-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-22 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-22 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-11 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-11 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2001-10-11 00:00:00 | IT HAS BEEN EXPLAINED TO THIS WRITER | | | THAT THE BUILDING IS A MIXED OCCUPANCY | | | CONTAINING THREE SEPARATE OCCUPANCIES, | | | TENANT 1 WAS EXPLAINED AS BUSINESS, | | | TENANT 2 WAS EXPLAINED AS STORAGE, | | | AND TENANT 3 INDUSTRIAL. NO MECHANICAL | | | OR HVAC INFORMATION PROVIDED WITH | | | PLANS. | | | TENANT # 1 | | | A) NO INTERIOR FINISH INFORMATION | | | PROVIDED FOR WALLS AND CEILINGS. | | | TENANT # 2 | | | A) NO EMERGENCY LIGHTING SHOWN. | | | B) NO INTERIOR FINISH INFORMATION | | | PROVIDED FOR WALLS AND CEILINGS. | | | TENANT # 3 | | | A) NO INFORMATION ON SEPARATION WALL | | | FOR BETWEEN TENANT # 2 AND TENANT # 3. | | | B) NO EMERGENCY LIGHTING SHOWN. | | | C) SPRAY BOOTH CANNOT BE APPROVED | | | BECAUSE NOT ENOUGH INFORMATION HAS | | | BEEN PROVIDED. MAKE-UP AIR, DISCHARGE | | | OF EXHAUST DUCT ON RAILROAD EASEMENT, | | | REQUIRED 3 FOOT SEPARATION DISTANCE FROM | | | SPRAY BOOTH. BOOTH GOING TO BE | | | GROUNDED? | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2001-10-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-26 |
Time |
09:17 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-26 00:00:00 | INSUFFICIENT INFORMATION FOR MECH | | | REVIEW MECHANICAL PULLED FROM MASTER. | | | ADDITIONAL FEES AND PERMIT FOR MECH | | | REQUIRED. PLANS REQUIRED WITH MECH | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
I |
Date |
2001-10-22 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-10-22 |
Time |
08:47 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-10-22 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2001-10-22 00:00:00 | INSUFFICIENT INFORMATION FOR REVIEW | | | | | | NO INFO PROVIDED FOR MECHANICAL OR | | | HVAC. SUBMIT PLANS AND PERMIT PRIOR TO | | | WORK | | | PROVIDE SPECS AND PLANS ON SPRAY BOOTH | | | PRIOR TO ANY WORK BEING DONE ON THE | | | SPRAY BOOTH. | | | SPRAY BOOTH REQUIRES SEPARATE PERMIT AND | | | PLANS | | | SUPPRESSION SYSTEM FOR SPRAY BOOTH | | | REQUIRES SEPARATE PERMIT AND PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
I |
Date |
2001-10-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-10 |
Time |
12:15 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-10-10 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2001-10-10 00:00:00 | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW. PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | 1.INDICATE WILL A.C. SYSTEM BE NEW OR | | | OR EXISTING. | | | | | | 2.SHOW SIZING OF DUCTWORK AND GRILLS. | | | | | | 3.CFM DISTRIBUTION. | | | | | | 4.MANUFACTURER DATA ON A.C. SYSTEM. | | | | | | 5.PROVIDE OUTSIDE AIR CALCULATIONS | | | AS PER ASHRAE 62-89. | | | | | | 6.PROVIDE AIR BALANCE SCHEDULE SHOWING | | | COMPLIANCE WITH 1997 SMC 501.2. | | | | | | | | | ADDITIONAL PLANS AND PERMITS FOR SPRAY | | | BOOTH AND FIRE SUPRESSION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-10-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-10-18 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-10-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-10-18 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|