Plan Review Details - Permit 01091277
Plan Review Stops For Permit 01091277
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-11-03 Cont ID  
Sent By jgomez Date 2001-11-03 Time 15:37 Rev Time 2.00
Received By jgomez Date 2001-11-03 Time 15:36 Sent To  
Notes
2001-11-03 00:00:00APPROVED WITH PROVISO:
 1-DESIGN CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM IS NOT COMPLETE WITH
 THE REQUIRED INFORMATION. SEE
 COMMENTS ON FORM SUBMITTED.
 -NOTE: ENGINEER SEALING THIS FORM SHALL
 SIGN AND SEAL THE STRUCTURAL DRAWINGS
 AS WELL, SINCE HE IS ASSUMING THE
 STRUCTURAL DESIGN FOR THIS HOUSE.
 2-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 3-BEDROOM WINDOWS TO BE REPLACED NEED TO
 MEET EGRESS REQUIREMENTS OF SECTION
 1005.4 SBC 1997: 24" MIN. CLEAR HEGHT
 OPENING, 20" MIN. CLEAR WIDTH OPENING
 AND 5 SQ. FT. MIN. TOTAL CLEAR OPENING
 4-BEFORE INSTALLATION PROVIDE PRODUCT
 APPROVAL FOR:
 A)FRENCH DOORS.
 B)ENTRY DOOR WITH SIDELITES SINGLE
 ASSEMBLY AS SHOWN ONPLANS.
 C)WINDOW MULLIONS.
 D)GARAGE DOORS THAT MEET THE DESIGN
 PRESSURES SPECIFIED BY THE ARCHITECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-23 Cont ID  
Sent By jgomez Date 2001-10-23 Time 17:48 Rev Time 3.00
Received By jgomez Date 2001-10-23 Time 17:48 Sent To  
Notes
2001-10-23 00:00:00CHECKLIST:
 1-AFTER ORIGINAL DRAWINGS ARE REVISED
 PAY IMPACT FEES AND BRING RECEIPT AND
 STAMPED DRAWINGS.
 2-NEED TO RECORD NOTICE OF COMMENCEMENT.
 3-PROVIDE SURVEY THAT MATCHES FLOOR PLAN
 4-ARCHITECT TO COMPLETELY FILL OUT THE
 DESIGN CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM. SEE ATTACHED.
 5-ARCHITECT TO SPECIFY THE DESIGN
 PRESSURES CALCULATED AT ALL EXTERIOR
 OPENINGS. SEC 1606 SBC 1997.
 6-PROVIDE ENERGY CALCULATIONS REQUIRED
 BY THE FLORIDA ENERGY EFFICIENCY CODE
 FOR BUILDING CONSTRUCTION, 1997 ED.
 7-SPECIFY SAFETY GLASS AS REQUIRED BY
 SEC. 2405.2 SBC 1997.
 8-PROVIDE CURRENT PRODUCT APPROVAL AND
 COMPLETE INFORMATION FOR STORM PANELS
 OR APPLY FOR A SEPARATE PERMIT.
 -NEED KEY PLAN, COMPLETE INSTALLATION
 SCHEDULE AND CLEARLY INDICATE ON
 APPROVED STORM PANEL DRAWINGS THE
 SPECIFIC MOUNTING CONDITIONS & ANCHORS
 TO BE USED ACCORDING TO APPROPRIATE
 CONDITIONS.
 9-CLEARLY INDICATE ON PLANS TYPE & SIZES
 OF WINDOWS IN ORDER TO VERIFY COMPLIAN
 -CE WITH THE EGRESS REQUIREMENTS OF
 SEC. 1005.4 SBC 1997.
 ALSO, IDENTIFY ALL ROOMS IN FLOOR PLAN
 10-PROVIDE PRODUCT APPROVAL FOR:
 A)ROOF TILE.
 B)WINDOW MULLIONS.
 C)FRENCH DOORS.
 D)ENTRY DOOR WITH SIDELITES SINGLE
 ASSEMBLY AS SHOWN ON EXT. ELEVATIONS.
 E)GARAGE DOORS (NEED DESIGN PRESSURES
 CALCULATED BY THE ARCHITECT TO VERIFY
 ADEQUACY FOR THIS BUILDING)
  
 11-SPECIFY ATTIC VENTILATION AS REQUIRED
 BY SEC. 2309.6 SBC
 12-SPECIFY CONNECTORS, FOOTING SIZE, ETC
 SEE COMMENTS ON 3 OF 5.
 13-OWES $86.35 FOR UPDATED VALUATION AND
 RADON FEES.
  
  
  
 NOTE:
 -PLEASE RETURN REVIEWED SET AFTER ALL
 CORRECTIONS ARE DONE TO THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-03 Cont ID  
Sent By dpalmer Date 2001-10-03 Time 10:57 Rev Time 0.00
Received By dpalmer Date 2001-10-03 Time 10:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-11-05 Cont ID  
Sent By pkrauss Date 2001-10-11 Time 09:36 Rev Time 0.35
Received By pkrauss Date 2001-10-11 Time 09:31 Sent To  
Notes
2001-10-11 00:00:00 
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE PLANS AND THE FOLLOWING
 INFORMATION WITH MECHANICAL PERMIT
 APPLICATION.
  
  
 1.ENERGY CALCS WITH MANUAL J CALCS FOR
 SIZING OF THE HVAC SYSTEM.
  
 2.MODEL, BTUS, HEAT STRIP, AND SEER
 OF THE AHU/C.U.
  
 3.DUCTWORK, INDICATE SIZE, R-VALUE
 CFM TO EACH ROOM AND SIZE OF GRIILS.
  
 4.INDICATE HOW AHU IS SUPPPORTED IN
 THE GARAGE.
  
 5.INDICATE LINE SIZE, MATERIAL OF AND
 PATH OF ALL PIPING.
  
 6.TERMINATION OF CONDENSATE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096 EXT.
 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-11-02 Cont ID  
Sent By kstevens Date 2001-11-02 Time 17:16 Rev Time 0.33
Received By kstevens Date 2001-11-02 Time 17:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-10 Cont ID  
Sent By kstevens Date 2001-10-10 Time 16:04 Rev Time 0.33
Received By kstevens Date 2001-10-10 Time 16:04 Sent To  
Notes
2001-10-10 00:00:00DENIED
 REFERENCE: SPC-94 -SEC 104.2.1
  
 PLEASE PROVIDE A SANITARY RISER DIAGRAM.
 SHOW ALL PIPE SIZES AND VENTING FOR PLAN
 REVIEW.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-09-26 Cont ID  
Sent By sgraham Date 2001-09-26 Time 09:44 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***