Plan Review Details - Permit 01091019
Plan Review Stops For Permit 01091019
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2001-12-20 Cont ID  
Sent By jgomez Date 2001-12-20 Time 14:25 Rev Time 0.25
Received By jgomez Date 2001-12-20 Time 14:25 Sent To  
Notes
2001-12-20 00:00:001-REVISED ENERGY CALCULATIONS. OK.
 2-TWO HOUR CONCRETE BLOCK FIRE RATED
 CERTIFICATION:
 -CERTIFICATION LETTER CONTENT IS OK
 BUT NEED TO BE ADDRESSED TO THE CITY
 OF WEST PALM BEACH, NOT THOMAS
 CARPENTRY.
 ALSO, CORRECT THE ADDRESS. IT IS
 WEST PALM BEACH, NOT ROYAL PALM BEACH.
 -PROVIDE ORIGINAL LETTER WITH ORIGINAL
 SIGNATURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2001-11-21 Cont ID  
Sent By jgomez Date 2001-11-21 Time 17:09 Rev Time 0.25
Received By jgomez Date 2001-11-21 Time 17:09 Sent To  
Notes
2001-11-21 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-11-14 Cont ID  
Sent By jgomez Date 2001-11-14 Time 16:37 Rev Time 0.25
Received By jgomez Date 2001-11-14 Time 16:37 Sent To  
Notes
2001-11-14 00:00:00TRUSS DRAWINGS CHECKLIST:
  
 1-ENGINEERED TRUSSES ARE DESIGNED USING
 DIFFERENT MEAN ROOF HEIGHTS. THERE IS
 ONLY ONE MEAN ROOF HEIGHT FOR ENTIRE
 BUILDING. REVIEW ALL ENGINEERED
 TRUSSES AND REVISE AS REQUIRED.
 TABLE 1606.2A SBC 1997.
 2-SOME TRUSSES ARE DESIGNED USING WALL
 HEIGHT. THIS APPLIES TO FLAT ROOF.
 USE MEAN ROOF HEIGHT FOR SLOPED ROOF.
 REVISE AS REQUIRED.
 3-GENERAL DETAILS:
 A)THERE ARE TWO DIFFERENT ENGINEERS.
 COMPLY WITH REQUIREMENTS OF CHAPTER
 471 FL. STATUTES WHEN CHANGING ENG'R.
 B)UPDATE GENERAL DETAILS AS REQUIRED.
 C)DETAILS & SPECS ARE NOT LEGIBLE.
  
  
 NOTES:
 -THESE COMMENTS HAVE BEING ADDRESSED ON
 PREVIOUS REVIEWS.
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01091019.
 -COMMENTS APPLY TO PERMIT #S:
 01091019, 01091025, 01091042, 01091054
 AND 01091060.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-10-24 Cont ID  
Sent By jgomez Date 2001-10-22 Time 18:43 Rev Time 0.50
Received By jgomez Date 2001-10-22 Time 18:43 Sent To  
Notes
2001-10-22 00:00:00APPROVED WITH PROVISO:
  
 1-REVISE ENERGY CALCULATIONS:
 A)THIS IS A COMPUTER PROGRAM. CHANGES BY
 HAND ARE NOT ALLOWED BECAUSE THEY WILL
 ALTER THE ACTUAL CALCULATIONS.
 SEE NUMBER OF UNITS AND NUMBER OF
 BEDROOMS AND REVISE ORIGINAL FORM
 AS REQUIRED.
  
  
 2-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. THE
 MEAN ROOF HEIGHT AND THE DESIGN
 PRESSURES DON'T MATCH. SEE TABLE
 1606.2A SBC 1997.
  
 3-PROVIDE CERTIFICATION FOR TWO HOUR
 FIRE RATED CONCRETE BLOCK BETWEEN
 TOWNHOUSES IN ACCORDANCE WITH SECTION
 709.3 SBC 1997.
  
  
  
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01091019.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091019, 01091025, 01091042, 01091054
 AND 01091060.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-12 Cont ID  
Sent By jgomez Date 2001-10-12 Time 17:49 Rev Time 1.00
Received By jgomez Date 2001-10-12 Time 17:49 Sent To  
Notes
2001-10-12 00:00:00CHECKLIST:
 1-REVISE ENERGY CALCULATIONS. SEE
 COMMENTS ON FIRST PAGE OF EACH LOT.
 2-REVISE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. SEE
 COMMENTS ON FORM.
 3-PROVIDE CERTIFICATION FOR TWO HOUR
 FIRE RATED CONCRETE BLOCK BETWEEN
 TOWNHOUSES.
 4-BRING PAID RECEIPT FOR IMPACT FEES.
 5-PAY ADDITIONAL FEES FOR VALUATION
 UPDATE AND RADON FEES. SEE ATTACHED
 RECEIPTS AND BRING PAID RECEIPTS.
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT
 #01091019.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091019, 01091025, 01091042, 01091054
 AND 01091060.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-03 Cont ID  
Sent By dpalmer Date 2001-10-03 Time 23:51 Rev Time 0.00
Received By dpalmer Date 2001-10-03 Time 23:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-10-24 Cont ID  
Sent By mcarsill Date 2001-10-24 Time 10:14 Rev Time 0.00
Received By mcarsill Date 2001-10-24 Time 10:14 Sent To  
Notes
2001-10-24 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 4) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REQUIREMENTS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-11-15 Cont ID  
Sent By ndenmark Date 2001-11-15 Time 14:05 Rev Time 0.50
Received By ndenmark Date 2001-11-15 Time 14:05 Sent To  
Notes
2001-11-15 00:00:00REVISION DATED 11/15/01

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-09-29 Cont ID  
Sent By hmoser Date 2001-09-29 Time 10:42 Rev Time 0.33
Received By hmoser Date 2001-09-29 Time 10:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-09-26 Cont ID  
Sent By kstevens Date 2001-09-26 Time 19:35 Rev Time 0.33
Received By kstevens Date 2001-09-26 Time 19:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-09-25 Cont ID  
Sent By sgraham Date 2001-09-25 Time 10:10 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***