Plan Review Details - Permit 01090788
Plan Review Stops For Permit 01090788
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-02-07 Cont ID  
Sent By btrobaug Date 2002-02-07 Time 17:46 Rev Time 0.00
Received By btrobaug Date 2002-02-07 Time 17:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-03 Cont ID  
Sent By dpalmer Date 2001-10-03 Time 23:22 Rev Time 0.00
Received By dpalmer Date 2001-10-03 Time 23:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-09-29 Cont ID  
Sent By hmoser Date 2001-09-29 Time 08:33 Rev Time 0.33
Received By hmoser Date 2001-09-29 Time 08:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-09-29 Cont ID  
Sent By jleech Date 2001-09-29 Time 07:41 Rev Time 0.33
Received By jleech Date 2001-09-29 Time 07:41 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-12-24 Cont ID  
Sent By rmcdouga Date 2001-12-24 Time 15:31 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-12-24 00:00:00TRUSSES OK 12-24-01

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-10-17 Cont ID  
Sent By rmcdouga Date 2001-10-17 Time 09:39 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-10-17 00:00:00TRUSSES
 UNSAT
  
 1) TRUSS H7B (U=3913#) HAS AN UPLIFT
 VALUE THAT EXCEEDS UPLIFT VALUE
 SPECIFIED IN THE ANCHOR SCHEDULE (C2 U=
 2750#). PLEASE REVIEW AND CORRECT.
  
 2) THE ANCHOR SCHEDULE DOES NOT SPECIFY
 THE COMPLETE MODEL NUMBER OF THE
 ANCHOR,SUCH AS HETA 12,16,20, ETC.
  
 3) THERE IS A MARK A OPT. ON THE ROOF
 FRAMING PLAN (SHEET3A), HOWEVER, THERE
 IS NOT A CORRESPONDING MARK A IN THE
 ANCHOR SCHEDULE. PLEASE CLARIFY.
  
 4) THE TRUSS I.D. LABELS ON THE ON THE
 TRUSS LAYOUT DO NOT CORRESPOND WITH THE
 TRUSS DRAWINGS FOR SEVERAL OF THE
 TRUSSES. T-11,T-11DS,H2710,ETC.
  
 5) PLEASE INDICATE THE TRUSS THAT THE
 C5 (2 PLY TRUSS HANGER) IS TO BE INSTALL
 -ED ON. SEE TRUSS LAYOUT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-10-17 Cont ID  
Sent By rmcdouga Date 2001-10-17 Time 08:52 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-10-17 00:00:00************BUILDING PROVISO************
  
 1) PROVIDE ENGINEERED DETAIL OF ALUMINUM
 COLUMN BASES AT COVERED PORCH INDICATING
 METHOD OF ANCHORING.
  
 2)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - (UN-CLIPPED) TUBE MULLIONS (THE ONES
 THAT WERE SUBMITTED EXPIRED ON 5/1/00)

Review Stop Z ZONING
Rev No 1 Status P Date 2001-09-27 Cont ID  
Sent By sgraham Date 2001-09-27 Time 07:53 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***