| 2001-10-06 00:00:00 | *************BUILDING UNSAT************* |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) THE 8050 HORIZONTAL SLIDING WINDOW |
| | INTHE MASTER BEDROOM MUST COMPLY WITH |
| | SEC.1005.4 OF THE 97 SBC FOR EMERGENCY |
| | EGRESS REQUIREMENTS. (MINIMUM NET CLEAR |
| | OPENING HEIGHT 24" AND WIDTH OF 20") |
| | |
| | 3) ONE OF THE INTERIOR BEARING WALLS |
| | EXTENDS TO THE CENTER OF THE FRENCH |
| | DOORS AT THE STUDY. INDICATE ON THE |
| | PLANS THE SIZE OF THIS LOAD BEARING |
| | HEADER. |
| | |
| | 4) THE ROOF SHEATHING AT GABLE ENDS IS |
| | REQUIRED TO BE NAILED WITH 8D COMMON |
| | NAILS AT 4"O.C. AT EDGES AND 6"O.C. |
| | INTERMEDIATE WITHIN FIVE FEET (5') OF |
| | THE ROOF EDGE INCLUDING OVERHANG. |
| | |
| | 5) THE ENERGY CODE INCORRECTLY LISTS |
| | EXTERIOR WALLS AS WOOD FRAME WITH AN R |
| | VALUE OF 4.2. PLEASE CORRECT. |
| | |
| | 6) TEMPORARY SALES OFFICE IN GARAGE OF |
| | MODEL MUST BE APPROVED BY THE PLANNING |
| | AND ZONING DEPARTMENT AND THE BUILDING |
| | OFFICIAL. YOU WILL BE REQUIRED TO SUB- |
| | MIT A PROPOSAL FOR REVIEW. THE FOLLOWING |
| | ITEMS MUST BE ADDRESSED. ADDITIONAL |
| | INFORMATION MAY BE REQUIRED AFTER REVIEW |
| | BY BUILDING OFFICIAL. |
| | A) A SURVEY SHOWING OFF STREET PARKING |
| | ON A NON-DUSTING SURFACE. ONE SPACE FOR |
| | EACH 350 SQ.FT. TO INCLUDE REQUIRED |
| | ACCESSIBLE PARKING. |
| | B) SALES OFFICE MUST MEET ACCESSIBILITY |
| | REQUIREMENTS INCLUDING ACCESSIBLE TOILET |
| | FACILITIES. |
| | C)A CONDITIONAL CERTIFICATE OF OCCUPANCY |
| | WILL BE REQUIRED BEFORE THE OFFICE CAN |
| | BE OPENED. |
| | THE FINAL C.O. FOR THE RESIDENCE WILL BE |
| | ISSUED AFTER THE TEMPORARY COMPONENTS |
| | HAVE BEEN REMOVED. |
| | D) YOU MUST SUBMIT A LETTER FROM ONE OF |
| | THE PRINCIPLES WITH THE COMPANY (SIGNED |
| | AND SEALED OR WITH CORPRATE SEAL) TO THE |
| | BUILDING OFFICIAL WITH YOUR REQUEST, |
| | INDICATING THE LENGTH OF TIME THIS |
| | CONDITION WILL EXIST AND THAT THE WALLS, |
| | A/C DROPS, ETC. WILL BE REMOVED AND THAT |
| | THE GARAGE DOOR WILL BE INSTALLED. |
| | |
| | 7) TEMPORARY EXTERIOR WALL MUST MEET |
| | WINDLOAD REQUIREMENTS. PROVIDE A DETAIL |
| | OF THIS WALL INDICATING ATTACHMENT TO |
| | STRUCTURE. |
| | |
| | 8) PROVIDE PRODUCT APPROVALS FOR FRENCH |
| | DOORS AND WINDOW. |
| | |
| | 9) PROVIDE IMPACT PROTECTION FOR FRENCH |
| | DOORS AND WINDOW AT GARAGE. |
| | |
| | 10) PROVIDE DETAIL OF TRAP FENCE AT |
| | GARAGE INDICATING TYPE OF CONSTRUCTION, |
| | METHOD OF ANCHORING, ETC. |
| | |