Plan Review Details - Permit 01090531
Plan Review Stops For Permit 01090531
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-07 Cont ID  
Sent By jwitmer Date 2002-01-07 Time 12:54 Rev Time 1.25
Received By hpiskura Date   Time   Sent To  
Notes
2002-01-07 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01090531
 2800 N FLAGLER
 ROOFTOP COMMUNICATIONS EQUIPMENT
 PROVISO: SHEET E-1, CONDUIT FROM ROOFTOP
 TO 8TH FLOOR TO PROVIDE PRODUCT INFORMA-
 TION FOR PROTECTION OF FIRE RATED FLOOR
 CEILING RATED ASSEMBLY AS PER SBC 705.6.
 ALL CODE SECTIONS 705.2.4 REGARDING
 SPECIAL PROVISIONS FOR REFUSE CHUTE EN-
 CLOSURES ARE TO BE MAINTAINED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-09 Cont ID  
Sent By hpiskura Date 2001-10-09 Time 08:03 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-10-09 00:00:00THE LEEDCO ENGINEERS ANALYSIS CITES THE
 1994 STANDARD BUILDING CODE (SBC) AND A
 135 MPH WIND SPEED.THE CITY IS
 CURRENTLY ENFORCING THE 1997 SBC.
 ALSO, THIS BUILDING IS A 100' +/- TALL,
 NOT THE 40' CALLED OUT.THE DESIGN
 INVESTIGATION SHOULD BE IN ACCORDANCE
 WITH
 ASCE 7-95 USING A WIND SPEED BETWEEN
 THE140 AND 150 MPH CONTOURS FOUND IN
 FIG. 6-1 OF THAT PUBLICATION.
  
 SHEET GN1, 1-1.11 RELATED DOCUMENTS,
 DOES NOT SHOW THE 1997 SBC AS THE
 BUILDING CODE DESIGN.THE BOCA CODE
 CITED ISNOT RECOGNIZED BY THE CITY NOR
 ARE SPECIFIC EDITIONS OF THE OTHER
 DESIGN STANDARDS NOTED.
  
  
 SHEET S3, PROVIDE AN ENGINEERING
 ANALYSIS OR TEST DATA FOR THE VARIOUS
 ANTENNAE'S ABILITYTO SUSTAIN THE
 WINDLOADS AT THIS LOCATION.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-02-12 Cont ID  
Sent By dpalmer Date 2002-02-12 Time 08:29 Rev Time 0.00
Received By dpalmer Date 2002-02-12 Time 08:29 Sent To  
Notes
2002-02-12 00:00:00PASSED AS FOR THE FIRST TWO TIMES .

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-12-11 Cont ID  
Sent By dpalmer Date 2001-12-11 Time 21:52 Rev Time 0.00
Received By dpalmer Date 2001-12-11 Time 21:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-09-27 Cont ID  
Sent By dpalmer Date 2001-09-27 Time 16:03 Rev Time 0.00
Received By dpalmer Date 2001-09-27 Time 16:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-02-13 Cont ID  
Sent By mcarsill Date 2002-02-13 Time 10:00 Rev Time 0.00
Received By mcarsill Date 2002-02-13 Time 10:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-12-13 Cont ID  
Sent By mcarsill Date 2001-12-13 Time 15:17 Rev Time 0.00
Received By mcarsill Date 2001-12-13 Time 15:17 Sent To  
Notes
2001-12-13 00:00:001) THE PREVIOUS PLAN REVIEW COMMENTS
 FROM FIRE RESCUE WERE NOT ADDRESSED.
 PLEASE CLARIFY CONDUIT ROUTES NEAR OR
 IN TRASH CHUTE. CERTAIN RESTRICTIONS
 WILL APPLY TO THE ROUTING OF THE
 CONDUITS WITH REGARDS TO THE TRASH
 CHUTE. PLEASE REPSOND AND PROVIDE
 DETAILS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-09-25 Cont ID  
Sent By mcarsill Date 2001-09-25 Time 15:22 Rev Time 0.00
Received By mcarsill Date 2001-09-25 Time 15:22 Sent To  
Notes
2001-09-25 00:00:001) PLANS SEEM TO INDICATE THAT CONDUITS
 FROM THE ROOF WILL RUN DOWN ALONG THE
 TRASH CHUTE. IT ALSO REFERS THAT
 CONDUITS WILL RUN NEAR THE TRASH CHUTE.
 PLEASE CLARIFY.
  
 CAPTAIN MIKE CARSILLO
 659-8096 EXT 8497
 835-2910

Review Stop Z ZONING
Rev No 1 Status P Date 2001-09-24 Cont ID  
Sent By sgraham Date 2001-09-24 Time 08:35 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***