| Plan Review Stops For Permit 01090226 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-10-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-26 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-26 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-10-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-01 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-01 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2001-10-01 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | 3)NOTE: PLEASE NOTE THATNEW FOOTER | | | STEEL TO BE BONDED TO SERVICE. 250-50 | | | | | | 4)NOTE: PLEASE CLARIFY RISER DIAGRAM | | | SHOWING MAIN DISCONNECT, BUT PLANS DO | | | NOT SHOW MAIN NEXT TO METER. PLEASE ALSO | | | CLARIFY THE MAIN PANEL BEING SHOWN WITH | | | A MCB.? | | | | | | 5) PLEASE CLARIFY EQUIPMENT GROUNDING | | | METHOD BETWEEN FIRST MEANS OF DISCONNECT | | | AND PANEL(S). EQUIPMENT GROUNDING | | | CONDUCTORS ARE TO BE SIZED BY 250-122. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2001-10-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-26 |
Time |
10:27 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-10-26 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2001-10-26 00:00:00 | | | | MECHANICAL PLANS TO BE SUBMITTED BY | | | MECHANICAL CONTRACTOR AS PER LETTER | | | DATED 10-18-01.MECHANICAL CONTRACTOR | | | WILL BE RESPONSIBLE FOR SUBMITTING | | | PERMIT/PLANS AS WELL AS FEES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-10-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-02 |
Time |
13:15 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-10-02 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2001-10-02 00:00:00 | *******************DENIED*************** | | | | | | | | | 1.PLEASE PROVIDE INFORMATION ON THE | | | EXISTING A/C. | | | | | | A.MAKE, MODEL, BTU & SEER/EER | | | RATING. | | | | | | B.WHAT IS THE SQUARE FOOTAGE THAT | | | THE UNIT IS CURRENTLY SUPPLYING | | | AIR TO.NO CALCS ARE SUPPLIED | | | TO DETERMINE IF EXISTING UNIT | | | WILL BE ABLE TO SUPPLY AN | | | ADDITIONAL 410 CFM AS INDICATED | | | ON THE PLAN TO THE MASTER BED | | | ROOM. | | | | | | 3.ENERGY CALCS NEED TO ACCOMPANIED BY | | | THE ACCA MANUAL J, ACCA MANUAL N, OR | | | THE ASHRAE COOLING AND HEATING LOAD | | | CALCULATION MANUAL AS PER FLORIDA | | | ENERGY CODE SECTION 607.1.ABC.1. | | | | | | 4.INICATE ON THE PLAN WHERE THE | | | EXISTING AIR HANDLER UNITS RETURN | | | AIR IS LOCATED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-12-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-08 |
Time |
10:06 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-12-08 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-11-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-02 |
Time |
12:44 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-10-02 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2001-11-01 00:00:00 | FAILED | | | | | | 1) PLEASE SUPPLY SCUPPER DETAILS FOR | | | BALCONY IN CASE ALTERNATIVE GUARDRAIL IS | | | USED. SHOW SIZE AND LOCATION OF SCUPPER | | | AND OVERFLOW SCUPPER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
6 |
Status |
F |
Date |
2002-05-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-05-08 |
Time |
10:36 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-08 00:00:00 | FLOOR TRUSSES DENIED | | | | | | 1) FLOOR TRUSS LAYOUT IS REQUIRED TO | | | HAVE THE WET SIGNATURE, EMBOSSED SEAL | | | AND DATE OF THE TRUSS ENGINEER. | | | | | | 2)THE ENGINEERED TRUSS DRAWINGS FROM THE | | | TRUSS COMPANY FOR THE FLOOR TRUSSES ARE | | | REQUIRED TO BE SUBMITTED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2002-05-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-05-08 |
Time |
10:33 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-08 00:00:00 | REVISION TO CHANGE FROM ROOF TRUSSES TO | | | CONVENTIONAL FRAMING IS OK. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2002-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-03-11 |
Time |
18:30 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-11 00:00:00 | FLOOR TRUSSES DENIED | | | | | | 1) PLEASE SUBMIT (2) TWO SETS OF TRUSS | | | DRAWINGS AND LAYOUTS. (REQUIRED) | | | | | | 2) THE TRUSS DRAWINGS AND LAYOUT REQUIRE | | | THE ORIGINAL WET SIGNATURE, DATE AND | | | EMBOSSED SEAL OF THE TRUSS ENGINEER. | | | | | | 3) THE DRAWINGS AND LAYOUT ARE REQUIRED | | | TO BE REVIEWED AND APPROVED BY THE | | | DESIGNER OF RECORD FOR THE STRUCTURE. | | | THE LAYOUT MUST BE STAMPED REVIEWED AND | | | APPROVED BY THE ARCHITECT OR ENGINEER | | | AND BE SIGNED BY THEM. | | | | | | 4) SPECIFY ON THE TRUSS DRAWINGS AND | | | LAYOUT THE DESIGN CRITERIA THAT IS BEING | | | USED TO DESIGN THE TRUSSES.THE STRUCTURE | | | WAS DESIGNED USING THE 1997 STANDARD | | | BUILDING CODE SECTION 1606 WITH 110 MPH | | | WIND SPEED (FASTEST MILE). | | | | | | 5) THE ROOF TRUSS INFORMATION SUBMITTED | | | (VALLEY DETAIL, PIGGYBACK, ETC.) IS NOT | | | REQUIRED FOR FLOOR TRUSS REVIEW. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2001-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-12-08 |
Time |
11:35 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-08 00:00:00 | ************BUILDING PROVISO************ | | | | | | 1)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - DOUBLE HUNG WINDOWS (SHOWN ON PLANS) | | | - CASEMENT WINDOWS (THE PRODUCT APPROVAL | | | SUBMITTED HAD EXPIRED PRIOR TO 7-6-01, | | | THE DATE APPLICATION FOR PERMIT WAS | | | SUBMITTED) |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2001-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-10-31 |
Time |
15:39 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-31 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) PERMIT CAN NOT BE ISSUED UNTIL PLANS | | | APPROVED BY THE HISTORIC PRESERVATION | | | BOARD WITH THE PARAPET WALL (GUARDRAIL) | | | AROUND THE BALCONY ARE SUBMITTED FOR | | | REVIEW. STRUCTURAL DRAWINGS MUST BE | | | SIGNED, SEALED AND DATED BY THE DESIGNER | | | OF RECORD (ENGINEER). | | | | | | 2) INDICATE NUMBER, SIZE AND LOCATION OF | | | SCUPPERS AND OVERFLOW SCUPPERS ON THE | | | PLANS. SCUPPERS AND OVERFLOWS MUST | | | COMPLY WITH CHAPTER 11 OF THE S.P.C. AND | | | SECTION 1517.6.4 OF THE SBC. | | | | | | 3) THE DRAWN IN OR RED LINED REVISIONS | | | TO THE PLANS MUST BE INITIALED BY THE | | | DESIGNER OF RECORD (ENGINEER). | | | | | | 4) PROVIDE ENERGY CALCULATIONS | | | AS REQUIRED BY THE 1997 FLORIDA ENERGY | | | EFFICIENCY CODE FOR BUILDING | | | CONSTRUCTION. (THEY WERE MISSING FROM | | | RESUB) | | | | | | 5) PROVIDE PRODUCT APPROVALS FOR DOUBLE | | | HUNG WINDOWS. | | | | | | 6) SEPARATE PERMITS AND WILL BE REQUIRED | | | FOR ROOFING, MECHANICAL AND ELECTRICAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-10-01 |
Time |
09:42 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-01 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PROVIDE AT LEAST ONE BATHROOM WITH A | | | DOOR THAT HAS A 29 INCH CLEAR OPENING AS | | | REQUIRED BY THE 97 FL ACCESSIBILITY CODE | | | FOR BUILDING CONSTRUCTION. | | | | | | 3) NEW WINDOWS IN THE SECOND FLOOR BED- | | | ROOM (ABOVE THE SUNPORCH) MUST COMPLY | | | WITH SECT. 1005.4 OF THE 97 SBC. FOR | | | MINIMUM HEIGHT, WIDTH AND NET CLEAR | | | OPENING AREA FOR EGRESS. | | | | | | 4) PROVIDE (2) PRODUCT APPROVALS, KEY | | | PLANS AND INSTALLATION SCHEDULES | | | INDICATING THE SPECIFIC TYPES OF ANCHORS | | | TO BE USED FOR STORM PANELS. MISSLE | | | IMPACT PROTECTION IS REQUIRED FOR FRENCH | | | DOORS(SEE PRODUCT APPROVAL)AND ANY OTHER | | | GLAZED OPENINGS THAT ARE NOT IMPACT | | | RESISTENT. | | | | | | 5) STAIR WINDERS MUST COMPLY WITH SECT. | | | 1007.8.1 OF 97 SBC ( MIN. OF 6" TREAD | | | DEPTH AT THE NARROW EDGE & MIN. TREAD | | | DEPTH OF 11" AT A POINT 12" FROM THE | | | NARROW EDGE. | | | SECT. 3401.2.1 THE BUILDING OFFICIAL | | | SHALL DETERMINE THE EXTENT TO WHICH THE | | | EXISTING SYSTEM SHALL BE MADE TO CONFORM | | | TO THE REQUIREMENTS OF THE TECHINICAL | | | CODES FOR NEW CONSTRUCTION. | | | | | | 6) SHEET A-1 STATES THAT THE MINIMAL | | | POSITIVE AND NEGATIVE DESIGN PRESSURE | | | FOR ALL WINDOWS AND DOORS IS 34 PSF. | | | HOWEVER,THE STRUCTURAL NOTES ON SHEET | | | A-2 FOR A TWO STORY STRUCTURE INDICATE | | | A MINIMUM OF 39 PSF. | | | | | | 7) PROVIDE THE PRODUCT APPROVAL AND | | | MANUFACTURERS SPECIFICATIONS FOR BUR | | | USED ON BALCONY. | | | | | | 8) PROVIDE DETAILS AND SPECIFICATIONS | | | FOR THE CAST STONE BALLUSTRADE SHOWING | | | COMPLIANCE WITH 97 SBC SECT. 1015.3 | | | (SPACING OF INTERMEDIATE RAILS),1608.2.2 | | | (APPLIED LOADS) AND 1609.1.2 (ANCHORING | | | FOR WINDLOADS). | | | | | | 9) PROVIDE DETAILS OF STEEL COLUMNS, | | | COLUMN BASES AND COLUMN CAPS INDICATING | | | THE THICKNESS OF THE STEEL, TYPE OF | | | WELDS, SIZE OF PLATES, SIZE AND SPACING | | | OF HOLES AND IMBEDS, ETC. FOR THE | | | COLUMNS AT THE FRONT PORCH AND AT THE | | | LOGGIA. | | | | | | 10) SEPARATE PERMITS WILL BE REQUIRED | | | FOR ROOFING, MECHANICAL, PLUMBING AND | | | ELECTRICAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-09-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-09-28 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-09-28 00:00:00 | OK PER S.GRAHAM 9-10-01 RM |
|
|