Plan Review Details - Permit 01090187
Plan Review Stops For Permit 01090187
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-01-22 Cont ID  
Sent By jwitmer Date 2002-01-22 Time 12:58 Rev Time 0.50
Received By jwitmer Date 2002-01-22 Time 12:58 Sent To  
Notes
2002-01-22 00:00:00REVISION: DATED 01/11/02STRUCTURALOK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-12-04 Cont ID  
Sent By jwitmer Date 2001-12-04 Time 17:57 Rev Time 0.25
Received By jwitmer Date 2001-12-04 Time 17:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-10-30 Cont ID  
Sent By jwitmer Date 2001-10-30 Time 19:21 Rev Time 1.50
Received By jwitmer Date 2001-10-30 Time 19:21 Sent To  
Notes
2001-10-30 00:00:00BUILDING PLAN REVIEW
 PREMIT # 01090187
 3400 CELEBRATION BLVD
 CONT: CIMORILLI
 (561) 852-7535
  
 1)- SBC 1606.2.6.2 COMPONENTS & CLADDING
 THE CITY REQUIRES (2) PRODUCT TESTING RE
 PORTS, FOR THE EXTERIOR GLAZED OPENINGS:
 A) EXTERIOR DOORS FRENCH, REPORT WILL
 ALSO REQUIRE TESTING WITH THE
 TRANSOM & SIDE LIGHTS OR A INTERMED
 IATE FRAMING MEMBER OR LINTEL.
 B) GLAZED OPENINGS (WINDOWS) THE RE-
 PORT FOR FIXED WINDOWS UNDER LIMIT-
 ATIONS (3) "SINGLE UNIT APPLICA-
 TION" NO TRANSOM AS TESTED.
  
 CONTRACTOR TO HAVE PLANS ASSESED BY
 COUNTY BUILDING DEPARTMENT FOR IMPACT
 FEES.
  
 STATE RADON FEES PAID TO CITY $31.42.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-09-19 Cont ID  
Sent By jwitmer Date 2001-09-19 Time 13:09 Rev Time 3.00
Received By jwitmer Date 2001-09-19 Time 13:09 Sent To  
Notes
2001-09-19 00:00:00BUILDING PLAN REVIEW
 01090187
 3400 CELEBRATION BLVD
 CLUBHOUSE (R-3)
 CONT: GERARD GROUP INC
 TEL: (954) 383-2652
 FAX: (561) 795-4060
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= COUNTYWIDE AMENDMENTS 1997
 STANDARD BUILDING CODE
  
 1)- PLANS ARE TO BE SUBMITTED UNDER (2)
 INDEPENDENT PLAN REVIEWS:
 3400 CELEBRATION BLVD CLUBHOUSE $250.00
 3420 CELEBRATION BLVD GATEHOUSE $250.00
  
 2)- SBC*104.2.2 ADDITIONAL INFORMATION
 REQUIRED, A SUREY SIGNED SEALED & DATED
  
 3)- A PLOT PLAN THAT SHOWS LOCATION OF
 STRUCTURE AND PROPERTY LINES(SURVEY WILL
 WORK IF PROPOSED BUILDING IS LOCATED ON
 SURVEY).
  
 4)- FL. ENERGY CODE FOR EACH BUILDING.
 UNLESS NO AIR FOR THE GATEHOUSE.
  
 5)- SHEET A1.0 DOESN'T SHOW CHANGE IN
 GRADE, SHEET S-1 DOES DEPICT (2) 4"
 CHANGES IN GRADE. THE FAIR HOUSING ACT
 REFRENCES THE ANSI STANDARDS,SEE 303.2
 FOR CHANGE IN GRADE(VERTICAL).ACCESSIBLE
 ROUTES ANSI 402.2.
  
 6)- MISSING ARE (2) COPIES OF THE SOILS
 REPORT GIVING THE MINIMUM BEARING VALUE.
 SBC* 1804.2.7.2
  
 7)- SBC 1606.2.6.2 COMPONENTS & CLADDING
 THE CITY REQUIRES (2) PRODUCT TESTING RE
 PORTS, FOR THE EXTERIOR ENVELOPE OF THE
 BUILDING, THESE ARE THE ITEMS REQUIRING
 PRODUCT TESTING:
 A- EXTERIOR DOORS *
 B- SLIDING DOORS*
 C- GARAGE DOORS(OVERHEAD)*
 D- WINDOWS*
 E- SKYLIGHTS*
 F- ROOFING ASSEMBLIES
 *- GLAZED OPENINGS WILL REQUIRE
 STORM SHUTTERS IF OPENINGS DO NOT
 MEET THE REQUIREMENT FOR LARGE
 MISSLE RESISTANCE TESTING. A SEPER-
 ATE PERMIT WILL BE REQUIRED IF NOT
 PART OF THE BUILDING PERMIT PACKAGE
 ALSO READ THE CITIES OFFICIAL
 INTERPRETATION ON POLICIES, NOTE
 ITEMS 14 & 15. SEE THE REQUIREMENTS
 FOR THE INSTALATION SCHEDULE & KEY
 PLAN. COPY ATTACHED.
  
 8)- S-3-3 ROOF SYSTEMS BETWEEN THE FLAT
 & PITCHED ROOFING SYSTEMS, SBC
 1507.3.1.5. FLASHING & COUTERFLASHING AT
 WALL ABUTMENTS. PLEASE PROVIDE DETAILS.
 SBC 1507.3.1.6. WHEN CRICKETS REQUIRED.
  
 9)- S3-3 THIS SAME DETAIL SHOWS TRUSSES
 INSET IN THE MASONARY WALL, CHECK CLEAR-
 ENCES PLUS SHEET S1 INDICATES THE
 TRUSSES AND FILLED VERTICAL CELLS IN THE
 SAME SPACE????
  
 10)- SHEET S-2 STEEL COLUMN SCHEDULE:
 J-BOLT ANCHOR LENGTH NOT GIVEN.
  
 11)- FL ACCESSIBILITY CODE 4.6 PARKING
 AND PASSENGER LOADING ZONES.
  
 12)- FL ACCESSIBILITY CODE 4.5 GROUND &
 FLOOR SURFACES ALONG ACCESSIBLE ROUTES
 AND IN ACCESSIBLE ROOMS AND SPACES INCLU
 DING FLOORS, WALKS, STAIRS, RAMPS &
 CURB RAMPS SHALL BE STABLE, FIRM, SLIP-
 RESISTANT. ADDAGG A4.5 A STATIC COEFFICI
 ENT OF FRICTION OF 0.6 IS RECOMMENDED
 FOR ACCESSIBLE ROUTES AND 0.8 FOR RAMPS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096X8412

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-07-11 Cont ID  
Sent By btrobaug Date 2002-07-11 Time 17:51 Rev Time 0.00
Received By btrobaug Date 2002-07-11 Time 17:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-11-26 Cont ID  
Sent By dpalmer Date 2001-11-26 Time 21:52 Rev Time 0.00
Received By dpalmer Date 2001-11-26 Time 21:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-30 Cont ID  
Sent By dpalmer Date 2001-10-30 Time 17:33 Rev Time 0.00
Received By dpalmer Date 2001-10-30 Time 17:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-09-18 Cont ID  
Sent By dpalmer Date 2001-09-18 Time 20:44 Rev Time 0.00
Received By dpalmer Date 2001-09-18 Time 20:44 Sent To  
Notes
2001-09-18 00:00:00****************** UNSAT *************
  
 1)NOTE: PLEASE NOTE THAT NO LOAD CALCU-
 -LATIONS WERE SUBMITTED. PLEASE ALSO
 NOTE THAT ALL CONTINUOUS LOADS ARE TO
 BE SHOWN AT 125%. 215-5/220-3 CONTIN,
 PER 230-42 AND 215-2/3
  
 2)NOTE: PLEASE NOTE THAT ALL PLANS DONE
 BY AN ARCH/ENGINEER ARE TO BE SIGNED,
 DATED AND SEALED BY PERSON OF RECORD.
 PLEASE NOTE THAT MANY PLANS ARE MISSING
 SEAL. 481.221 AND 471.025.FS/FAC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2001-11-27 Cont ID  
Sent By mamini Date 2001-11-27 Time 14:02 Rev Time 0.00
Received By mamini Date 2001-11-27 Time 14:02 Sent To  
Notes
2001-11-27 00:00:00N/A
 1. PERMIT # 01090187 IS FOR THE CLUB-
 HOUSE ONLY.SITE WORKS WILL BE REVIEWED
 UNDER A SEPARATE PERMIT APPLICATIONS.
 PER GOLDEN WEST LIMTED PARTNERSHIP
 ( ARLAND COMMUNITY DEVELOPMENT ) .
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2001-10-26 Cont ID  
Sent By mamini Date 2001-10-26 Time 09:40 Rev Time 2.00
Received By mamini Date 2001-10-26 Time 09:40 Sent To  
Notes
2001-10-26 00:00:00FAILED:
 1. INSUFFICENT INFORMATIONS FOR CIVIL
 ENGINEERING REVIEW, PLEASE SUBMIT CIVIL
 PLANS FOR OUR REVIEW AND APPROVAL.
 2. CIVIL PLANS SUBMITTAL SHOULD INCLUDE
 STORM WATER CALCULATIONS, PERVIOUS &
 IMPERVIOUS CALCULATIONS FOR ENTIRE SITE,
 UNDERGROUND UTILITIES AND POLLUTION
 CONTROL PLANS.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2001-12-04 Cont ID  
Sent By rturnque Date 2001-12-04 Time 13:35 Rev Time 0.25
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2001-11-01 Cont ID  
Sent By mcarsill Date 2001-11-01 Time 09:52 Rev Time 0.00
Received By mcarsill Date 2001-11-01 Time 09:52 Sent To  
Notes
2001-11-01 00:00:001) BUILDING ADDRESSES REQUIRED ON THE
 BUILDINGS AND NOT ON THE PLANS.
 2) HOW IS THE FIRE HYDRANT THAT IS
 LOCATED ON THE MAIN STREET UTILIZED
 FOR THE CLUBHOUSE BUILDING WHEN IT
 APPEARS TO BE LOCATED ON THE OPPOSITE
 SIDE OF THE SECURITY BUILDING AND
 DRIVEWAY OPENING. PLEASE EXPLAIN
 RATIONALE OF WHY THERE IS NO FIRE
 HYDRANT LOCATED THE BUILDING.
 3) CLOSET WALLS NOT RATED. ROOM IS
 REQUIRED TO BE RATED SINCE NO FIRE
 SPRINKLER SYSTEM IS PRESENT.
 4) PLEASE INDICATE RATINGS OF DOORS
 8,9,AND 12.
 5) IS FIRE APPARATUS EXPECTED TO PASS
 UNDER THE OVERHANG. IT IS NOT HIGH
 ENOUGH.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-10-18 Cont ID  
Sent By mcarsill Date 2001-10-18 Time 16:58 Rev Time 0.00
Received By mcarsill Date 2001-10-18 Time 16:58 Sent To  
Notes
2001-10-18 00:00:00IT APPEARS THAT PREVIOUS COMMENTS FROM
 THIS DEPARTMENT HAVE NOT BEEN
 ADDRESSED. PLEASE ADDRESS COMMENTS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-09-11 Cont ID  
Sent By mcarsill Date 2001-09-11 Time 12:22 Rev Time 0.00
Received By mcarsill Date 2001-09-11 Time 12:22 Sent To  
Notes
2001-09-11 00:00:001) SEPARATE PLANS AND PERMITS REQUIRED
 FOR ANY SECURITY GATES PLANNED FOR
 USE.
 2) BUILDING ADDRESS REQUIRED PER CITY
 CODE 3343-00.
 3) PLEASE INDICATE FIRE HYDRANT
 LOCATIONS NEAR CLUBHOUSE.
 4) PLEASE PROVIDE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR WALLS
 AND CEILINGS.
 5) MECHANICAL, STORAGE AND JANITOR
 CLOSETS ARE TO BE AT LEAST ONE HOUR
 FIRE RATED SINCE NO FIRE SPRINKLER
 SYSTEM IS PRESENT.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2002-04-25 Cont ID  
Sent By pkrauss Date 2002-04-25 Time 11:53 Rev Time 0.35
Received By pkrauss Date 2002-04-25 Time 11:53 Sent To  
Notes
2002-04-25 00:00:00PROVISO:
  
 PLEASE NOTE AS PER FLORIDA
 ADMINISTRATIVE CODE, PLANS SEALED BY
 THE ENGINEER SHALL LEGIBLY INDICATE
 THEIR NAME ADDRESS AND NUMBER (OR TITLE
 BLOCK) ON EACH SHEET.
  
 FUTURE REVISIONS SHALL COMPLY WITH THE
 AFORMENTIONED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-12-05 Cont ID  
Sent By pkrauss Date 2001-12-05 Time 13:31 Rev Time 0.40
Received By pkrauss Date 2001-12-05 Time 13:10 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-10-25 Cont ID  
Sent By pkrauss Date 2001-10-25 Time 09:44 Rev Time 0.40
Received By pkrauss Date 2001-10-25 Time 09:36 Sent To  
Notes
2001-10-25 00:00:00*******************DENIED***************
  
 PLANS ARE NOT SEALED BY ENGINEER OF
 RECORD.
  
 FIRE DEPT COMMENTS FOR MECHANICAL
 CLOSET HAVING A 1 HOUR FIRE RATING.
 FIRE DAMPERS WILL BE REQUIRED AT THESE
 PENETRATIONS.PLEASE INDICATE FIRE
 DAMPERS ON PLAN AND SHOW DETAIL FOR
 INSTALLATIONAS PER 1997 SMC 610.1.2.
 FIRE DAMPERS SHALL COMPLY WITH THE
 REQUIREMENTS OF UL 555.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-09-28 Cont ID  
Sent By pkrauss Date 2001-09-28 Time 13:59 Rev Time 0.45
Received By pkrauss Date 2001-09-28 Time 13:47 Sent To  
Notes
2001-09-28 00:00:00******************DENIED****************
  
  
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR REVIEW.
  
 1.AIR BALANCE SCHEDULE SHOWING
 COMPLIANCE WITH 1997 SMC 501.2.
  
 2.RETURNS SHALL BE DUCTED INTO AHU AND
 NOT TRANSFERRED INTO CLOSET.
  
 3.FAN SHUTDOWN BY DUCT SMOKE DETECTOR
 SHALL HAVE NOTIFICATION TO ALARM &
 STROBE IN NORMALLY OCCUPIED AREAS AS
 PER NFPA 90A 4-4.4.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 5 Status P Date 2002-05-03 Cont ID  
Sent By kstevens Date 2002-05-03 Time 09:15 Rev Time 0.00
Received By kstevens Date 2002-05-03 Time 09:15 Sent To  
Notes
2002-05-03 00:00:00REVISION OK -

Review Stop P PLUMBING
Rev No 4 Status P Date 2001-12-15 Cont ID  
Sent By pschmitz Date 2001-12-15 Time 16:08 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2001-12-15 00:00:00PREVIOUS COMMENT S ADDRESSED. PES

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-11-29 Cont ID  
Sent By kstevens Date 2001-11-29 Time 08:54 Rev Time 1.25
Received By kstevens Date 2001-11-29 Time 08:54 Sent To  
Notes
2001-11-29 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) SHT A4.0 CLEAR FLOOR SPACE FOR URNAL
 SHALL BE 30"X48", PER FACBC SEC 4.18.3.
 DETAIL #3 SHOWS 2'5" FOR URNALS. PLEASE
 SHOW CLEAR FLOOR SPACE FOR HDCP URNAL.
  
 2) PREVIOUS COMMENT NOT ADDRESSED.
 PLEASE PROVIDE CALCULATIONS FOR MINIMUM
 FACILITIES FOR FIXTURES USING SPC TABLE
 407.
  
 REVIEW BY KEN STEVENS.
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-11-02 Cont ID  
Sent By kstevens Date 2001-11-02 Time 16:02 Rev Time 1.00
Received By kstevens Date 2001-11-02 Time 15:28 Sent To  
Notes
2001-11-02 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) PREVIOUS COMMENT NOT ADDRESSED.
 PAGE A4.0, BAR ELEVATION (8) PLEASE
 COMPLY WITH FACBC SEC 4.24. PROVIDE
 DETAILS ON PLANS.
 2) PREVIOUS COMMENT NOT ADDRESSED.
 PAGE A4.0 MENS RESTROOM (6)(11) URNALS
 PLEASE COMPLY WITH FABC SEC 4.18 AND
 4.22.5
 3) PREVIOUS COMMENT NOT ADDRESSED. PAGE
 P1.0 WATER HEATER TO BE READILY ACCESS-
 ABLE PER SPC SEC 501.7. PLEASE PROVIDE A
 PERMINATE SHIPS LADDER AND A WORKING
 PLATFORM FOR SERVICING, MINIMUM 30"X30"
 4) PREVIOUS COMMENT NOT ADDRESSED. PAGE
 P2.0 SANITARY ISOMETRIC. MENS ROOM URNAL
 AND ELECT. WATER COOLER CAN NOT DRAIN TO
 STACK ON A CROSS FITTING. PLEASE HAVE
 FIXTURES DRAIN TO STACK AT DIFFERENT
 HEIGHTS.
 5) PREVIOUS COMMENT NOT ADDRESSED. PAGE
 P2.0 WATER ISOMETRIC/PAGE P3.0 GENERAL
 NOTES #16 AIR CHAMBERS ARE QUICK FIX AND
 WATER HAMMER ARRESTORS SHOULD BE USED.
 HAMMER ARRESTORS SHALL PLACED PER MANU-
 FACTURE INSTALLATION INSTRUCTIONS AND
 WH-PDI 201 NOT AT TOP OF DROP AS SHOWN
 AT LAV IN MENS ROOM. ALSO SHOW SHUT OFF
 VALVES AT ALL HOSE BIBBS.
 6) PREVIOUS COMMENT NOT ADDRESSED. PAGE
 A4.0 & P1.0 DRINKING FOUNTAIN PLEASE
 COMPLY WITH FACBC SEC 5.15 & SEC 4.1.3
 (10)(A) FOR THOSE WHO HAVE DIFFICULTY
 BENDING OR STOOPING.
 7) PREVIOUS COMMENT NOT ADDRESSED.
 PLEASE PROVIDE CALCULATIONS FOR MINIMUM
 FACILITIES FOR FIXTURES. USE SCP TABLE
 407.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-03 Cont ID  
Sent By kstevens Date 2001-10-03 Time 19:53 Rev Time 0.50
Received By kstevens Date 2001-10-03 Time 19:53 Sent To  
Notes
2001-10-03 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
 1) PLEASE NOTE THAT ALL PLANS SUBMITTED
 BY AN ENGINEER ARE TO BE SIGNED, DATED,
 AND SEALED BY PERSON OF RECORD. PLEASE
 NOTE THAT MANY SHEETS ARE MISSING SEAL.
 471.025 FS/FAC.
 2) PAGE A4.0, BAR ELEVATION (8) PLEASE
 COMPLY WITH FACBC-97 SEC 4.24. PROVIDE
 DETAILS ON PLANS.
 3) PAGE A4.0 MENS RESTROOM (6) (11).
 PLEASE COMPLY WITH FACBC-97 SEC 4.18 &
 4.22.5
 4) PAGE P1.0 WATER HEATER TO BE READILY
 ACCESSIBLE PER SPC-94 SEC 501.7. PLEASE
 PROVIDE A PERMINATE SHIPS LADDER AND A
 WORKING PLATFORM FOR SERVICING, MINIMUM
 30" X 30".
 5) PAGE P2.0 SANITARY ISOMETRIC. MENS
 ROOM URNAL AND ELECT. WATER COOLER CAN
 NOT DRAIN TO STACK ON A CROSS. PLEASE
 HAVE FIXTURES DRAIN TO STACK AT DIFFER-
 ENT HEIGHTS.
 6) PAGE P2.0 WATER ISOMETRIC AIR CHAMB-
 ERS TO COMPLY WITH SPC-94 SEC 607.8.3,
 (ACCESSIBLE AND RECHARGABLE) PER WH-PDI
 201. IF WATER HAMMER ARRESTORS ARE USED,
 THEY SHALL COMPLY WITH MANUFACTURES IN-
 STALLATION INSTRUCTIONS FOR SIZING AND
 LOCATION AND WH-PDI 201 NOT AT TOP OF
 DROP. SHOW DETAILS ON ISO. ALSO SHOW
 SHUT OFF VALVES FOR ALL HOSE BIBBS.
 7) PAGES A4.0 & P1.0 DRINKING FOUNTAIN.'
 PLEASE COMPLY WITH FACBC-97 SEC 5.15 AND
 SEC 4.1.3(10)(A) FOR THOSE WHO HAVE TRO-
 BLE BENDING OR STOOPING.
 8) PAGE P3.0 GENERAL NOTES #16. SEE NOTE
 COMMENT #6 ABOVE.
 9) PLEASE PROVIDE CALCULATIONS FOR MIN-
 IMUM FACILITIES FOR FIXTURES. USE SPC-94
 TABLE 407.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2001-12-07 Cont ID  
Sent By lmartine Date 2001-12-07 Time 10:30 Rev Time 0.25
Received By lmartine Date   Time   Sent To  
Notes
2001-12-07 00:00:00NEED LANDSCAPE PLAN

Review Stop Z ZONING
Rev No 1 Status F Date 2001-10-25 Cont ID  
Sent By pkrauss Date 2001-12-05 Time 13:52 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-10-25 00:00:003 PARKING SPACES NEAR BIKE-RACK MUST BE
 ELIMINATED FOR TRAFFIC SAFETY