| Plan Review Stops For Permit 01090187 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-01-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-01-22 |
Time |
12:58 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2002-01-22 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2002-01-22 00:00:00 | REVISION: DATED 01/11/02STRUCTURALOK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-12-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-12-04 |
Time |
17:57 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2001-12-04 |
Time |
17:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-10-30 |
Time |
19:21 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2001-10-30 |
Time |
19:21 |
Sent To |
|
|
| Notes |
| 2001-10-30 00:00:00 | BUILDING PLAN REVIEW | | | PREMIT # 01090187 | | | 3400 CELEBRATION BLVD | | | CONT: CIMORILLI | | | (561) 852-7535 | | | | | | 1)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | THE CITY REQUIRES (2) PRODUCT TESTING RE | | | PORTS, FOR THE EXTERIOR GLAZED OPENINGS: | | | A) EXTERIOR DOORS FRENCH, REPORT WILL | | | ALSO REQUIRE TESTING WITH THE | | | TRANSOM & SIDE LIGHTS OR A INTERMED | | | IATE FRAMING MEMBER OR LINTEL. | | | B) GLAZED OPENINGS (WINDOWS) THE RE- | | | PORT FOR FIXED WINDOWS UNDER LIMIT- | | | ATIONS (3) "SINGLE UNIT APPLICA- | | | TION" NO TRANSOM AS TESTED. | | | | | | CONTRACTOR TO HAVE PLANS ASSESED BY | | | COUNTY BUILDING DEPARTMENT FOR IMPACT | | | FEES. | | | | | | STATE RADON FEES PAID TO CITY $31.42. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-09-19 |
Time |
13:09 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2001-09-19 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2001-09-19 00:00:00 | BUILDING PLAN REVIEW | | | 01090187 | | | 3400 CELEBRATION BLVD | | | CLUBHOUSE (R-3) | | | CONT: GERARD GROUP INC | | | TEL: (954) 383-2652 | | | FAX: (561) 795-4060 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | SBC*= COUNTYWIDE AMENDMENTS 1997 | | | STANDARD BUILDING CODE | | | | | | 1)- PLANS ARE TO BE SUBMITTED UNDER (2) | | | INDEPENDENT PLAN REVIEWS: | | | 3400 CELEBRATION BLVD CLUBHOUSE $250.00 | | | 3420 CELEBRATION BLVD GATEHOUSE $250.00 | | | | | | 2)- SBC*104.2.2 ADDITIONAL INFORMATION | | | REQUIRED, A SUREY SIGNED SEALED & DATED | | | | | | 3)- A PLOT PLAN THAT SHOWS LOCATION OF | | | STRUCTURE AND PROPERTY LINES(SURVEY WILL | | | WORK IF PROPOSED BUILDING IS LOCATED ON | | | SURVEY). | | | | | | 4)- FL. ENERGY CODE FOR EACH BUILDING. | | | UNLESS NO AIR FOR THE GATEHOUSE. | | | | | | 5)- SHEET A1.0 DOESN'T SHOW CHANGE IN | | | GRADE, SHEET S-1 DOES DEPICT (2) 4" | | | CHANGES IN GRADE. THE FAIR HOUSING ACT | | | REFRENCES THE ANSI STANDARDS,SEE 303.2 | | | FOR CHANGE IN GRADE(VERTICAL).ACCESSIBLE | | | ROUTES ANSI 402.2. | | | | | | 6)- MISSING ARE (2) COPIES OF THE SOILS | | | REPORT GIVING THE MINIMUM BEARING VALUE. | | | SBC* 1804.2.7.2 | | | | | | 7)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | THE CITY REQUIRES (2) PRODUCT TESTING RE | | | PORTS, FOR THE EXTERIOR ENVELOPE OF THE | | | BUILDING, THESE ARE THE ITEMS REQUIRING | | | PRODUCT TESTING: | | | A- EXTERIOR DOORS * | | | B- SLIDING DOORS* | | | C- GARAGE DOORS(OVERHEAD)* | | | D- WINDOWS* | | | E- SKYLIGHTS* | | | F- ROOFING ASSEMBLIES | | | *- GLAZED OPENINGS WILL REQUIRE | | | STORM SHUTTERS IF OPENINGS DO NOT | | | MEET THE REQUIREMENT FOR LARGE | | | MISSLE RESISTANCE TESTING. A SEPER- | | | ATE PERMIT WILL BE REQUIRED IF NOT | | | PART OF THE BUILDING PERMIT PACKAGE | | | ALSO READ THE CITIES OFFICIAL | | | INTERPRETATION ON POLICIES, NOTE | | | ITEMS 14 & 15. SEE THE REQUIREMENTS | | | FOR THE INSTALATION SCHEDULE & KEY | | | PLAN. COPY ATTACHED. | | | | | | 8)- S-3-3 ROOF SYSTEMS BETWEEN THE FLAT | | | & PITCHED ROOFING SYSTEMS, SBC | | | 1507.3.1.5. FLASHING & COUTERFLASHING AT | | | WALL ABUTMENTS. PLEASE PROVIDE DETAILS. | | | SBC 1507.3.1.6. WHEN CRICKETS REQUIRED. | | | | | | 9)- S3-3 THIS SAME DETAIL SHOWS TRUSSES | | | INSET IN THE MASONARY WALL, CHECK CLEAR- | | | ENCES PLUS SHEET S1 INDICATES THE | | | TRUSSES AND FILLED VERTICAL CELLS IN THE | | | SAME SPACE???? | | | | | | 10)- SHEET S-2 STEEL COLUMN SCHEDULE: | | | J-BOLT ANCHOR LENGTH NOT GIVEN. | | | | | | 11)- FL ACCESSIBILITY CODE 4.6 PARKING | | | AND PASSENGER LOADING ZONES. | | | | | | 12)- FL ACCESSIBILITY CODE 4.5 GROUND & | | | FLOOR SURFACES ALONG ACCESSIBLE ROUTES | | | AND IN ACCESSIBLE ROOMS AND SPACES INCLU | | | DING FLOORS, WALKS, STAIRS, RAMPS & | | | CURB RAMPS SHALL BE STABLE, FIRM, SLIP- | | | RESISTANT. ADDAGG A4.5 A STATIC COEFFICI | | | ENT OF FRICTION OF 0.6 IS RECOMMENDED | | | FOR ACCESSIBLE ROUTES AND 0.8 FOR RAMPS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096X8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-07-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-07-11 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-07-11 |
Time |
17:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-26 |
Time |
21:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-26 |
Time |
21:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-30 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-30 |
Time |
17:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-18 |
Time |
20:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-18 |
Time |
20:44 |
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | ****************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT NO LOAD CALCU- | | | -LATIONS WERE SUBMITTED. PLEASE ALSO | | | NOTE THAT ALL CONTINUOUS LOADS ARE TO | | | BE SHOWN AT 125%. 215-5/220-3 CONTIN, | | | PER 230-42 AND 215-2/3 | | | | | | 2)NOTE: PLEASE NOTE THAT ALL PLANS DONE | | | BY AN ARCH/ENGINEER ARE TO BE SIGNED, | | | DATED AND SEALED BY PERSON OF RECORD. | | | PLEASE NOTE THAT MANY PLANS ARE MISSING | | | SEAL. 481.221 AND 471.025.FS/FAC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2001-11-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-11-27 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2001-11-27 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2001-11-27 00:00:00 | N/A | | | 1. PERMIT # 01090187 IS FOR THE CLUB- | | | HOUSE ONLY.SITE WORKS WILL BE REVIEWED | | | UNDER A SEPARATE PERMIT APPLICATIONS. | | | PER GOLDEN WEST LIMTED PARTNERSHIP | | | ( ARLAND COMMUNITY DEVELOPMENT ) . | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-10-26 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-10-26 |
Time |
09:40 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2001-10-26 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2001-10-26 00:00:00 | FAILED: | | | 1. INSUFFICENT INFORMATIONS FOR CIVIL | | | ENGINEERING REVIEW, PLEASE SUBMIT CIVIL | | | PLANS FOR OUR REVIEW AND APPROVAL. | | | 2. CIVIL PLANS SUBMITTAL SHOULD INCLUDE | | | STORM WATER CALCULATIONS, PERVIOUS & | | | IMPERVIOUS CALCULATIONS FOR ENTIRE SITE, | | | UNDERGROUND UTILITIES AND POLLUTION | | | CONTROL PLANS. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-12-04 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2001-12-04 |
Time |
13:35 |
Rev Time |
0.25 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2001-11-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-01 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-01 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2001-11-01 00:00:00 | 1) BUILDING ADDRESSES REQUIRED ON THE | | | BUILDINGS AND NOT ON THE PLANS. | | | 2) HOW IS THE FIRE HYDRANT THAT IS | | | LOCATED ON THE MAIN STREET UTILIZED | | | FOR THE CLUBHOUSE BUILDING WHEN IT | | | APPEARS TO BE LOCATED ON THE OPPOSITE | | | SIDE OF THE SECURITY BUILDING AND | | | DRIVEWAY OPENING. PLEASE EXPLAIN | | | RATIONALE OF WHY THERE IS NO FIRE | | | HYDRANT LOCATED THE BUILDING. | | | 3) CLOSET WALLS NOT RATED. ROOM IS | | | REQUIRED TO BE RATED SINCE NO FIRE | | | SPRINKLER SYSTEM IS PRESENT. | | | 4) PLEASE INDICATE RATINGS OF DOORS | | | 8,9,AND 12. | | | 5) IS FIRE APPARATUS EXPECTED TO PASS | | | UNDER THE OVERHANG. IT IS NOT HIGH | | | ENOUGH. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-10-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-18 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-18 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2001-10-18 00:00:00 | IT APPEARS THAT PREVIOUS COMMENTS FROM | | | THIS DEPARTMENT HAVE NOT BEEN | | | ADDRESSED. PLEASE ADDRESS COMMENTS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-09-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-11 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-11 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2001-09-11 00:00:00 | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY SECURITY GATES PLANNED FOR | | | USE. | | | 2) BUILDING ADDRESS REQUIRED PER CITY | | | CODE 3343-00. | | | 3) PLEASE INDICATE FIRE HYDRANT | | | LOCATIONS NEAR CLUBHOUSE. | | | 4) PLEASE PROVIDE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR WALLS | | | AND CEILINGS. | | | 5) MECHANICAL, STORAGE AND JANITOR | | | CLOSETS ARE TO BE AT LEAST ONE HOUR | | | FIRE RATED SINCE NO FIRE SPRINKLER | | | SYSTEM IS PRESENT. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-04-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-25 |
Time |
11:53 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-04-25 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2002-04-25 00:00:00 | PROVISO: | | | | | | PLEASE NOTE AS PER FLORIDA | | | ADMINISTRATIVE CODE, PLANS SEALED BY | | | THE ENGINEER SHALL LEGIBLY INDICATE | | | THEIR NAME ADDRESS AND NUMBER (OR TITLE | | | BLOCK) ON EACH SHEET. | | | | | | FUTURE REVISIONS SHALL COMPLY WITH THE | | | AFORMENTIONED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-12-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-05 |
Time |
13:31 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-12-05 |
Time |
13:10 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-10-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-25 |
Time |
09:44 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-10-25 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2001-10-25 00:00:00 | *******************DENIED*************** | | | | | | PLANS ARE NOT SEALED BY ENGINEER OF | | | RECORD. | | | | | | FIRE DEPT COMMENTS FOR MECHANICAL | | | CLOSET HAVING A 1 HOUR FIRE RATING. | | | FIRE DAMPERS WILL BE REQUIRED AT THESE | | | PENETRATIONS.PLEASE INDICATE FIRE | | | DAMPERS ON PLAN AND SHOW DETAIL FOR | | | INSTALLATIONAS PER 1997 SMC 610.1.2. | | | FIRE DAMPERS SHALL COMPLY WITH THE | | | REQUIREMENTS OF UL 555. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-28 |
Time |
13:59 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-09-28 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2001-09-28 00:00:00 | ******************DENIED**************** | | | | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW. | | | | | | 1.AIR BALANCE SCHEDULE SHOWING | | | COMPLIANCE WITH 1997 SMC 501.2. | | | | | | 2.RETURNS SHALL BE DUCTED INTO AHU AND | | | NOT TRANSFERRED INTO CLOSET. | | | | | | 3.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | SHALL HAVE NOTIFICATION TO ALARM & | | | STROBE IN NORMALLY OCCUPIED AREAS AS | | | PER NFPA 90A 4-4.4.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2002-05-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-03 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-03 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2002-05-03 00:00:00 | REVISION OK - |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-12-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-15 |
Time |
16:08 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-15 00:00:00 | PREVIOUS COMMENT S ADDRESSED. PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-11-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-29 |
Time |
08:54 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2001-11-29 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2001-11-29 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SHT A4.0 CLEAR FLOOR SPACE FOR URNAL | | | SHALL BE 30"X48", PER FACBC SEC 4.18.3. | | | DETAIL #3 SHOWS 2'5" FOR URNALS. PLEASE | | | SHOW CLEAR FLOOR SPACE FOR HDCP URNAL. | | | | | | 2) PREVIOUS COMMENT NOT ADDRESSED. | | | PLEASE PROVIDE CALCULATIONS FOR MINIMUM | | | FACILITIES FOR FIXTURES USING SPC TABLE | | | 407. | | | | | | REVIEW BY KEN STEVENS. | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-11-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-02 |
Time |
16:02 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2001-11-02 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2001-11-02 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) PREVIOUS COMMENT NOT ADDRESSED. | | | PAGE A4.0, BAR ELEVATION (8) PLEASE | | | COMPLY WITH FACBC SEC 4.24. PROVIDE | | | DETAILS ON PLANS. | | | 2) PREVIOUS COMMENT NOT ADDRESSED. | | | PAGE A4.0 MENS RESTROOM (6)(11) URNALS | | | PLEASE COMPLY WITH FABC SEC 4.18 AND | | | 4.22.5 | | | 3) PREVIOUS COMMENT NOT ADDRESSED. PAGE | | | P1.0 WATER HEATER TO BE READILY ACCESS- | | | ABLE PER SPC SEC 501.7. PLEASE PROVIDE A | | | PERMINATE SHIPS LADDER AND A WORKING | | | PLATFORM FOR SERVICING, MINIMUM 30"X30" | | | 4) PREVIOUS COMMENT NOT ADDRESSED. PAGE | | | P2.0 SANITARY ISOMETRIC. MENS ROOM URNAL | | | AND ELECT. WATER COOLER CAN NOT DRAIN TO | | | STACK ON A CROSS FITTING. PLEASE HAVE | | | FIXTURES DRAIN TO STACK AT DIFFERENT | | | HEIGHTS. | | | 5) PREVIOUS COMMENT NOT ADDRESSED. PAGE | | | P2.0 WATER ISOMETRIC/PAGE P3.0 GENERAL | | | NOTES #16 AIR CHAMBERS ARE QUICK FIX AND | | | WATER HAMMER ARRESTORS SHOULD BE USED. | | | HAMMER ARRESTORS SHALL PLACED PER MANU- | | | FACTURE INSTALLATION INSTRUCTIONS AND | | | WH-PDI 201 NOT AT TOP OF DROP AS SHOWN | | | AT LAV IN MENS ROOM. ALSO SHOW SHUT OFF | | | VALVES AT ALL HOSE BIBBS. | | | 6) PREVIOUS COMMENT NOT ADDRESSED. PAGE | | | A4.0 & P1.0 DRINKING FOUNTAIN PLEASE | | | COMPLY WITH FACBC SEC 5.15 & SEC 4.1.3 | | | (10)(A) FOR THOSE WHO HAVE DIFFICULTY | | | BENDING OR STOOPING. | | | 7) PREVIOUS COMMENT NOT ADDRESSED. | | | PLEASE PROVIDE CALCULATIONS FOR MINIMUM | | | FACILITIES FOR FIXTURES. USE SCP TABLE | | | 407. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-10-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-03 |
Time |
19:53 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-10-03 |
Time |
19:53 |
Sent To |
|
|
| Notes |
| 2001-10-03 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | 1) PLEASE NOTE THAT ALL PLANS SUBMITTED | | | BY AN ENGINEER ARE TO BE SIGNED, DATED, | | | AND SEALED BY PERSON OF RECORD. PLEASE | | | NOTE THAT MANY SHEETS ARE MISSING SEAL. | | | 471.025 FS/FAC. | | | 2) PAGE A4.0, BAR ELEVATION (8) PLEASE | | | COMPLY WITH FACBC-97 SEC 4.24. PROVIDE | | | DETAILS ON PLANS. | | | 3) PAGE A4.0 MENS RESTROOM (6) (11). | | | PLEASE COMPLY WITH FACBC-97 SEC 4.18 & | | | 4.22.5 | | | 4) PAGE P1.0 WATER HEATER TO BE READILY | | | ACCESSIBLE PER SPC-94 SEC 501.7. PLEASE | | | PROVIDE A PERMINATE SHIPS LADDER AND A | | | WORKING PLATFORM FOR SERVICING, MINIMUM | | | 30" X 30". | | | 5) PAGE P2.0 SANITARY ISOMETRIC. MENS | | | ROOM URNAL AND ELECT. WATER COOLER CAN | | | NOT DRAIN TO STACK ON A CROSS. PLEASE | | | HAVE FIXTURES DRAIN TO STACK AT DIFFER- | | | ENT HEIGHTS. | | | 6) PAGE P2.0 WATER ISOMETRIC AIR CHAMB- | | | ERS TO COMPLY WITH SPC-94 SEC 607.8.3, | | | (ACCESSIBLE AND RECHARGABLE) PER WH-PDI | | | 201. IF WATER HAMMER ARRESTORS ARE USED, | | | THEY SHALL COMPLY WITH MANUFACTURES IN- | | | STALLATION INSTRUCTIONS FOR SIZING AND | | | LOCATION AND WH-PDI 201 NOT AT TOP OF | | | DROP. SHOW DETAILS ON ISO. ALSO SHOW | | | SHUT OFF VALVES FOR ALL HOSE BIBBS. | | | 7) PAGES A4.0 & P1.0 DRINKING FOUNTAIN.' | | | PLEASE COMPLY WITH FACBC-97 SEC 5.15 AND | | | SEC 4.1.3(10)(A) FOR THOSE WHO HAVE TRO- | | | BLE BENDING OR STOOPING. | | | 8) PAGE P3.0 GENERAL NOTES #16. SEE NOTE | | | COMMENT #6 ABOVE. | | | 9) PLEASE PROVIDE CALCULATIONS FOR MIN- | | | IMUM FACILITIES FOR FIXTURES. USE SPC-94 | | | TABLE 407. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-12-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-12-07 |
Time |
10:30 |
Rev Time |
0.25 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-07 00:00:00 | NEED LANDSCAPE PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2001-10-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-05 |
Time |
13:52 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |