| Plan Review Stops For Permit 01090049 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-20 |
Time |
17:40 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2001-11-20 |
Time |
17:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-10-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-10-22 |
Time |
17:02 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2001-10-22 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2001-10-22 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01090049 | | | 1555 PALM BEACH LAKES # 9TH FL | | | ANDERSON MOORE CONSTRUCTION | | | TEL : 626-4411 | | | FAX : 626-4411 | | | CELL: 662-1819 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | | | | 1)-SBC 412.6.1 REQUIRES THE ELEVATOR | | | LOBBY TO BE SEPERATED FROM THE REMAINDER | | | OF THE BUILDING WITH 1 HR RATED | | | CONSTRUCTION. | | | SBC 412.6.2 EXIT STAIRWAYS, CHUTES, | | | JANITOR CLOSETS,SERVICE ROOMS- MECH., | | | GUEST ROOMS, ETC., SHALL NOT OPEN INTO | | | THE ELEVATOR LOBBY. | | | | | | 2)- SHEET A-1 DETAIL#2: PROVIDE A FIRE | | | DESIGN NUMBER FOR THE PARTITION DEPICTED | | | | | | 3)- FL ACCES CODE 4.13.6 MANEUVERING | | | CLEARENCES AT DOORS, 23 & 34 REQUIRE | | | 12" ON THE PUSH SIDE OF THE DOOR. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096X8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-18 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | THE COMMON PATH OF TRAVEL FROM THE | | | VICINITY OF OFFICE #132 EXCEEDS THE 75' | | | ALLOWED BY SBC 1004.1.3.PLEASE REVISE | | | AS NECESSARY. | | | | | | SBC 412.6.1 REQUIRES ELEVATOR LOBBIES TO | | | BE SEPARATED FROM THE REMAINDER OF THE | | | BUILDING WITH 1 HOUR FIRE RATED | | | CONSTRUVCTION.SEE ALSO 412.6.2. | | | | | | THE EXIT DOORS SERVING THE NORTH SIDE | | | OFFICE SPACE DO NOT MEET THE 1/2 | | | DIAGONAL DISTANCE SEPARATION | | | REQUIREMENTS OF SBC 1004.1.4.PLEASE | | | REVISE AS NECESSARY. | | | | | | PROVIDE A FIRE DESIGN NUMBER FOR THE | | | PARTITION SHOWN IN SECTION 2/A1.SEE | | | SBC 701.5. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-17 |
Time |
22:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-17 |
Time |
22:37 |
Sent To |
|
|
| Notes |
| 2001-09-17 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT PLANS MUST | | | CONTAIN TITLE BLOCK BY THE ARCH OF | | | RECORD. 61G15-23 FS/FAC 481.221 | | | PLEASE SEE PANEL SCHEDULES. | | | | | | 2)NOTE: PLEASE CLARIFY PANEL "LA", PANEL | | | IS SHOWN AS "MLO". PLEASE NOTE THAT | | | MAIN IS REQ`D PER 384-16E | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-11-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-11-02 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-09-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-05 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-05 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-22 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-10-22 |
Time |
09:04 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-10-22 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-24 |
Time |
16:32 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-09-24 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2001-09-24 00:00:00 | ******************DENIED**************** | | | | | | | | | PLEASE IDENTIFY ALL FIRE DAMPERS ON | | | PLAN.PROVIDE A INSTALLATION DETAIL. | | | | | | AREAS WITH 300 CFM OR GREATER SHALL HAVE | | | A RETURN AIR FROM THAT SPACE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | | 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-30 |
Time |
09:48 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-10-30 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-09-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-09-12 |
Time |
10:37 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-09-12 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2001-09-12 00:00:00 | DENIED | | | REFERENCES SPC-94 - FACBC-97 | | | | | | 1) PAGE A-3 HDCP RESTROOM, LAV TO COMPLY | | | WITH FACBC-97 SECT. 4.19.2. | | | | | | 2) PAGE A-3 WATER RISER DIAGRAM. AIR | | | CHAMBERS TO COMPLY WITH SPC-94 SECT. | | | 607.8.3 ACCESSABLE AND RECHARGABLE. IF | | | WATER HAMMER ARRESTORS ARE USED THEY | | | SHALL COMPLY WITH MANUFACTURE'S INSTALL- | | | ATION INSTRUCTIONS AND WH-PDI 201 FOR | | | SIZE AND LOCATION. (NOT AT TOP OF DROP) | | | | | | 3) PAGE A-3 WATER RISER DIAGRAM. EACH | | | WATER SUPPLY BRANCH LINE SHALL HAVE A | | | SHUTOFF VALVE INSTALLED. SPC-94 SEC. | | | 610.4.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|