Plan Review Details - Permit 01081573
| Plan Review Stops For Permit 01081573 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-02-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-02-11 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-25 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-25 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-09-25 00:00:00 | THE 4" SLAB CONSTRUCTED UNDER PERMIT | | | 00110838 IS INADEQUATE FOR A FOUNDATION. | | | SEE SBC 1804.1.3 AND REVISE AS NECESSARY | | | | | | PROVIDE A MORE DETAILED PLAN FOR THE | | | CONNECTION OF THE TRUSSES TO THE | | | BUILDING, INCLUDE AN ANALYSIS OF THE | | | LOADING THAT WILL BE ASSUMED BY THE | | | TAPCONS. | | | | | | SPECIFY THE TRUSS ANCHORS TO BE USED OR | | | THE LOADS TO BE RESISTED RE: SECTION A. | | | | | | SPECIFY THE WALL THICKNESS AND WELD | | | DETAIL FOR THE 3 X 3 STEEL COLUMNS. | | | | | | SHOW THE CONNECTION DETAILS FOR THE | | | PRECAST COLUMN COVERS. | | | | | | SHOW THE ROOF VENTILATION FOR THE ATTIC | | | SPACE REQUIRED BY SBC 2309.7. | | | | | | DETAIL "B"HOW IS THIS CONNECTED?IS | | | THE EXISTING HOUSE BLOCK, TILE OR WOOD | | | FRAME? | | | | | | PROVIDE TEST REPORTS OR NOTICE OF ACCEPT | | | ANCE FOR THE ROOF COVERING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-09-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-05 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-05 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-02-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-02-11 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2002-02-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-02-11 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-09-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-09-25 |
Time |
12:47 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |