| Plan Review Stops For Permit 01081524 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-09-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-14 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-10-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-19 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-19 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-10-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-01 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-01 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2001-10-01 00:00:00 | **************** UNSAT ************ | | | | | | 1)NOTE: PLEASE NOTE THAT RESPONSE TO | | | FIRST COMMENT IN LETTER, PLEASE NOTE | | | THAT ART: 220-12B DOES NOT MENTION ANY- | | | -THING ABOUT TRACK LIGHTING AT STORE | | | FRONTS. 220-12A PERTAINS TO LOADS FOR | | | RECEPTS AT STOREFRONTS ONLY. | | | TRACK LIGHTING LOADS ARE FOR ANYWHERE | | | IN THE STORE. | | | | | | 2)NOTE: PLEASE NOTE THAT AMENDED PLANS | | | ARE NOT SIGNED,DATED OR SEALED BY THE | | | ENGINEER OF RECORD. PER 471.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-10 |
Time |
21:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-10 |
Time |
21:12 |
Sent To |
|
|
| Notes |
| 2001-09-10 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SHOW LOAD CALCUALTIONS | | | FOR TRACK LIGHTING PER 220-12B | | | | | | 2)NOTE: PLEASE NOTE THAT PLANS SHOW | | | COLOR CODING FOR 277V/480V TO BE ORANGE | | | FOR B PHASE, PLEASE NOTE THAT COLOR | | | PER LOCAL AMENDMENT FOR 277/480 IS TO BE | | | PURPLE. ART:215 LOCAL | | | | | | 3)NOTE: PLEASE NOTE OUTLET SPACING TO | | | MEET LOCAL CODE FOR STORAGE AREA AND | | | SALES AREA, EVERY 20' OF WALL SPACE. | | | | | | 4)NOTE: PLEASE NOTE THAT PLAN COVER PAGE | | | CALL FOR 1996 NEC. PLEASE NOTE THAT | | | WE ARE UNDER THE "99" NEC. PLEASE CHANGE | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-09-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-14 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-10-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-09 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-09 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-09-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-04 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-04 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2001-09-04 00:00:00 | 1) PLEASE PROVIDE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR WALLS | | | AND CEILINGS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-10-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-29 |
Time |
15:25 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-10-29 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2001-10-29 00:00:00 | RESUB - NO CHANGES TO MECH.APPROVED BY | | | NANCY DENMARK 10-19-01.PROVISO ON | | | PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-19 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-10-19 |
Time |
15:37 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-10-19 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2001-10-19 00:00:00 | AHU TO BE INSTALLED WITH RESPECT TO | | | BUILDING CONSTRUCTION TO ALLOW FOR | | | REPAIR OR REPLACEMENT OF EQUIPMENT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-09-12 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-09-12 |
Time |
14:58 |
Rev Time |
0.26 |
| Received By |
ndenmark |
Date |
2001-09-12 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-09-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-14 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-09-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-14 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|