Plan Review Details - Permit 01081489
Plan Review Stops For Permit 01081489
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-11-06 Cont ID  
Sent By jwitmer Date 2001-11-06 Time 13:06 Rev Time 1.00
Received By jwitmer Date 2001-11-06 Time 13:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-09-28 Cont ID  
Sent By jwitmer Date 2001-09-28 Time 06:58 Rev Time 2.00
Received By jwitmer Date 2001-09-28 Time 06:58 Sent To  
Notes
2001-09-28 00:00:00BUILDING PLAN REVIEW
 PERMIT #01081489
 323 MANGO PROMENADE
 O/B BUSSEY, MARVIN D.
 SBC= 1997 STANDARD BUILDING CODE
 1)- ROOFING: SBC 1503.3.2 ROOF ASSEM-
 BLIES SHALL BE TESTED FOR 110 MPH WIND
 ZONE. THE CITY ACCEPTS ROOFING REPORTS
 FROM SBCCI OR DADE COUNTY PRODUCT APPROV
 ALS.
  
 2)- THE RECONFIGURATION OF THE FRONT
 WALL UNDER THE FRONT PORCH, SHOW WALL
 SECTION, DETAILS OF STRAPING TOP / BOT-
 TOM PLATES HEADER SIZE AND JACK STUDS.
  
 3)- SSBC 104.2.2. DISCREPANCY, MORE
 INFORMATION REQUIRED, PAGE 2 INDICATE RE
 PAIR OF 12" FLOOR JOIST BUT DEPICTED ARE
 FLOOR TRUSSES, WHICH ARE THEY & WHAT
 TYPE OF REPAIR IS REQUIRED.
  
 4)- SBC 1606.4.1/ 1707.4.1 WINDOWS:
 A SEPERATE PERMIT WAS PULLED TO REPLACE
 OVER 50 % OF THE GLAZED OPENINGS IN THE
 HOUSE. BY CODE SEE ATTACHMENT ARTICLE
 #(4) WHEN 50% OF OPENINGS ARE REPLACED
 AND THE WINDOWS DO NOT HAVE LARGE MISSLE
 IMPACT THEY WILL REQUIRE STORM SHUTTERS.
 SBCCI REPORTS OR DADE COUNTY PRODUCT APP
 ROVAL (2) COPIES. ATTACHED IS A COPY OF
 A FASTENING SCHEDULE.
  
 5)- DEMONSTRATE CODE COMPLIANCE: DOES
 THE ROOF FRAMING SYSTEM HAVE CONTINIOUS
 STRAPING FROM ROOF FRAMING MEMBERS TO
 THE WALL MEMBERS, HEADERS TO VERTICAL
 FRAMING MEMBERS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-09-04 Cont ID  
Sent By dpalmer Date 2001-09-04 Time 08:14 Rev Time 0.00
Received By dpalmer Date 2001-09-04 Time 08:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-09-07 Cont ID  
Sent By pkrauss Date 2001-09-07 Time 13:04 Rev Time 0.45
Received By pkrauss Date 2001-09-07 Time 13:04 Sent To  
Notes
2001-09-07 00:00:00MECH PERMIT 01081490.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-09-05 Cont ID  
Sent By jleech Date 2001-09-05 Time 17:53 Rev Time 0.50
Received By jleech Date 2001-09-05 Time 17:53 Sent To  
Notes
***NONE***