Plan Review Details - Permit 01081416
Plan Review Stops For Permit 01081416
Review Stop E ELECTRICAL
Rev No 6 Status P Date 2003-02-24 Cont ID  
Sent By sthyng Date 2003-03-19 Time 11:11 Rev Time 0.75
Received By btrobaug Date 2003-02-24 Time 12:48 Sent To P
Notes
2003-02-24 00:00:00TO "P" IN BOX./WRT

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-02-03 Cont ID  
Sent By dpalmer Date 2003-02-18 Time 11:40 Rev Time 1.00
Received By btrobaug Date 2003-02-03 Time 13:16 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2002-05-17 Cont ID  
Sent By btrobaug Date 2003-01-30 Time 17:04 Rev Time 0.00
Received By dpalmer Date 2002-05-17 Time 06:06 Sent To P
Notes
2002-05-17 00:00:00*************** UNSAT *************
 ***** NO REVIEW TO BE DONE, SEPARTE
 PLANS TO BE SUBMITTED WITH AN ELECTRICAL
 PERMIT APPLICATION.
  
  
 1)NOTE: PLEASE NOTE THAT PANEL SCHEDULE
 AND LOAD CALCULATIONS, DO NOT CORRELATE.
 PLEASE NOTE MIN AND MAX OCP WITH MANY
 ITEMS ON PANEL SCHEDULE NEED TO BE
 ADDRESSED. PLEASE NOTE MANY OTHER NEC
 ISSUES.
 PLEASE SUBMIT A NEW SETWITH ELECTRICAL
 CONTRACTOR./PERMIT APPLICATION.
  
 IF THERE ARE ANY QUESTIONS, OR IF A
 MEETING IS NEEDED, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2002-05-17 Cont ID  
Sent By dpalmer Date 2002-04-25 Time 09:03 Rev Time 0.00
Received By dpalmer Date 2002-04-25 Time 09:03 Sent To  
Notes
2002-04-25 00:00:00***************REVISION NEEDED *********
  
 1)NOTE: PLEASE NOTE THAT THERE ARE
 EQUIPMENT GROUNDING CONDUCTORS SHOWN
 BETWEEN METER AND FIRST MEANS OF DISC.
 PLEASE NOTE THAT THIS IS PARALLELING THE
 NEUTRAL WHICH IS NOT PERMITTED.
  
 2)NOTE: PLEASE NOTE MISSING EQUIPMENT
 GROUND BETWEEN MAINS AND DISC`S 250-122.
  
  
 3)NOTE: PLEASE NOTE MISSING SD`S UP AND
 DOWN STAIRS TO BE IN CLOSE PROXIMITY AND
 LEADING TO THE FLOOR ABOVE. 2-2.1.1.1,
 2-5.2.1.4
  
 4)NOTE: PLEASE NOTE THAT THE SERVICE
 ENTRANCE CONDUCTOR ARE SHOWN AS ONE
 SIZE ON SHEET 10 AND ANOTHER ON SHEET
 11? PLEASE CORRELATE PLANS FOR THE
 CONDUCTOR SIZES.
  
 5)NOTE: PLEASE NOTE MISSING OUTLET
 LOWER LEVEL.210-52
  
 PLEASE REVISE THE ABOVE AND SUBMIT FOR
 REVIEW BEFORE FINAL ELEC INSPECTION IS
 CALLED IN. IF THERE ARE NAY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2002-05-17 Cont ID  
Sent By btrobaug Date 2002-04-01 Time 14:32 Rev Time 0.00
Received By dpalmer Date 2002-03-27 Time 13:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-02-26 Cont ID  
Sent By btrobaug Date 2002-02-26 Time 17:10 Rev Time 0.00
Received By btrobaug Date 2002-02-26 Time 16:59 Sent To R
Notes
2002-02-26 00:00:00***************UNSAT!*******************
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION AND RESUBMIT FOR REVIEW:
  
 1) AN A.I.C. RATING TO THE FIRST MEANS
 OF DISCONNECT AND INDICATE THE RATING
 OF OCP FOR SAME.
  
 2) INDICATE THE LOCATION OF THE SERVICE
 ON THE PLAN.
  
 3) INDICATE PANEL LOCATIONS ON PLAN,ALSO
 SIZE AND TYPE OF RACEWAYS AND
 CONDUCTORS FEEDING SAME.(CONDUITS
 LEAVING PANELS "A" & "B" ARE NOTED AS
 GOING "TO HOUSE SERVICE",PLEASE
 CLARIFY.)
  
 4) THERE ARE NO BATH ROOM G.F.I'S ON
 PANEL SCHEDULES ( OR ADDED TO LOAD
 CALCULATIONS) AS PER 210-11(C)(3).
  
 5) THE WATER HEATER CIRCULATING PUMP IS
 NOT SHOWN ON PANEL SCHEDULE.
  
 6) WATER HEATER IS LISTED AT 1.5
 KW.,PLEASE CONFIRM.
  
 7) OVEN IS LISTED AT 1.5KW.PLEASE
 CONFIRM.A GAS COOKTOP IS SHOWN ON PLAN,
 AND A 8 KW. RANGE.PLEASE CLARIFY WHAT
 APPLIANCES ARE BEING INSTALLED AND THE
 CORRECT NAME PLATE RATING FOR SAME.
  
 8) PANEL "B" LOAD CALCS SHOW 3 AHU'S AT
 10KW'S EACH.AIR HANDLER CALCS SHOW A
 TOTAL OF 20KW'S FOR THESE THREE
 UNITS.PLEASE CORRECT.
  
 9) ACCU'S #1,2,&3 ARE LISTED ON 40 AMP
 BREAKERS PROTECTING #10 WIRE.CLARIFY.
  
 10) THE WATER HEATER LISTED ON PANEL"B"
 IS SHOWN ON A SINGLE POLE BREAKER,BUT
 LISTED ON CIRCUITS 10 & 12.
  
 11) THE DRYER LISTED ON PANEL"A"IS SHOWN
 ON CIRCUIT #2.IT IS ALSO SHOWN AS 8KW.
  
 12) KITCHEN COUNTER TOP RECEPTACLES PER
 210-52(C)(1).
  
 13) PLEASECHECK RECEPTACLE LOCATIONS
 TO COMPLY WITH 210-52(A)(2)(A).SEE
 PLANS.
  
 14) PLEASE NOTE SMOKE DETECTOR
 LOCATIONS AND COMPLY WITH NFPA-72.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/ 659-8096 EXT.8392

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-03-19 Cont ID  
Sent By sthyng Date 2003-03-19 Time 11:10 Rev Time 0.00
Received By sthyng Date 2003-03-19 Time 11:10 Sent To E
Notes
2003-03-19 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-26 Cont ID  
Sent By dpalmer Date 2003-02-26 Time 09:13 Rev Time 0.00
Received By dpalmer Date 2003-02-26 Time 09:12 Sent To B
Notes
2003-02-26 00:00:00REV TO LOU HATTEN'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-18 Cont ID  
Sent By dpalmer Date 2003-02-18 Time 11:40 Rev Time 0.00
Received By dpalmer Date 2003-02-18 Time 11:39 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-30 Cont ID  
Sent By btrobaug Date 2003-01-30 Time 17:04 Rev Time 0.00
Received By btrobaug Date 2003-01-27 Time 17:03 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-24 Cont ID  
Sent By pkrauss Date 2002-12-24 Time 15:17 Rev Time 0.25
Received By pkrauss Date 2002-12-24 Time 15:07 Sent To  
Notes
2002-12-24 00:00:00MECH PERMIT 02061884/REVISION

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-05-16 Cont ID  
Sent By hmoser Date 2002-05-16 Time 16:02 Rev Time 0.50
Received By hmoser Date 2002-05-16 Time 16:02 Sent To  
Notes
2002-05-16 00:00:00NO MECHANICAL PERMIT NUMBER ON
 APPLICATION
 H.M. 5/16/02

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-02-23 Cont ID  
Sent By hmoser Date 2002-02-23 Time 10:38 Rev Time 0.33
Received By hmoser Date 2002-02-23 Time 10:37 Sent To  
Notes
2002-02-23 00:00:00PLAN DENIED
 #1 NO MECHANICAL PLANS
 #2 NO MANUAL J
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 6 Status P Date 2003-03-01 Cont ID  
Sent By kstevens Date 2003-03-01 Time 06:27 Rev Time 0.25
Received By kstevens Date 2003-03-01 Time 06:27 Sent To  
Notes
2003-03-01 00:00:00REVISION OK - BAR SINK CHANGED TO FUTURE

Review Stop P PLUMBING
Rev No 5 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By kstevens Date 2003-02-28 Time 18:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-02-03 Cont ID  
Sent By btrobaug Date 2003-02-24 Time 13:39 Rev Time 0.75
Received By kstevens Date 2003-02-03 Time 18:07 Sent To  
Notes
2003-02-03 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT 11 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE OR REFLECT FLOOR PLAN.
 A) BATH #2 FROM THE SECOND FLOOR SHALL
 NOT TIE INTO DRAIN BETWEEN THE W/C AND
 THE LAV (VENT FOR POWDER ROOM) IN THE
 POWDER ROOM.
 B) BATH #2 SHOWS A SHOWER ON THE RISER
 DIAGRAM, BUT IS REMOVED ON FLOOR PLAN.
 PLEASE CLAIRFY.
 C) BAR SINK SHALL NOT DRAIN INTO THE
 WET VENT FOR BATHROOM #4. SINK SHALL TIE
 IN DOWN STREAM OF THE BATHROOM GROUP.
 SECTION 909.1.
  
 PLEASE MAKE CHANGES AND RESUBMIT.
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-05-17 Cont ID  
Sent By btrobaug Date 2003-02-03 Time 14:21 Rev Time 0.00
Received By kstevens Date 2002-05-17 Time 14:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-04-01 Cont ID  
Sent By dpalmer Date 2002-05-17 Time 06:07 Rev Time 0.50
Received By jleech Date 2002-04-01 Time 14:26 Sent To  
Notes
2002-04-01 00:00:00PROVISO;
 AS BUILT RISER DIAGRAM REQUIRED BERORE
 FINAL PLUMBING INSPECT.

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-02-23 Cont ID  
Sent By jleech Date 2002-02-23 Time 10:16 Rev Time 0.50
Received By jleech Date 2002-02-23 Time 10:16 Sent To  
Notes
2002-02-23 00:00:001.PLUMBING RISER NOT TO CODE;
 A.BAR SINK (2) NOT VENTED.
 B.SECOND FLOOR SHOWERS (4" RISER)
 NOT VENTED. WATER CLOSET FLUSHING
 PAST SHOWERS.
 C.LAUNDRY TUB NOT VENTED.
 2.SHOCK ARRESTORS TO COMPLY WITH 94 SPC
 SEC. 607.8.2.
 3.SEPORATE PERMIT AND PLANS REQUIRED
 FOR GAS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-04-07 Cont ID  
Sent By lhatten Date 2002-04-07 Time 15:18 Rev Time 2.50
Received By lhatten Date 2002-04-07 Time 15:16 Sent To  
Notes
2002-04-09 00:00:003RD SET REVIEW & STAMPED PLANS
 04/07/2002
 SAME AS ABOVE

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-03-03 Cont ID  
Sent By btrobaug Date 2002-03-03 Time 17:12 Rev Time 2.50
Received By lhatten Date 2002-03-03 Time 13:45 Sent To  
Notes
2002-03-22 00:00:00REVIEW & STAMPED PLANS 03/03/2002

Review Stop Z ZONING
Rev No 2 Status P Date 2002-02-21 Cont ID  
Sent By sgraham Date 2002-02-21 Time 14:43 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2001-09-05 Cont ID  
Sent By sgraham Date 2001-09-05 Time 09:17 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***