| Plan Review Stops For Permit 01081416 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2003-02-24 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-19 |
Time |
11:11 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2003-02-24 |
Time |
12:48 |
Sent To |
P |
|
| Notes |
| 2003-02-24 00:00:00 | TO "P" IN BOX./WRT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-18 |
Time |
11:40 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-02-03 |
Time |
13:16 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-30 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-17 |
Time |
06:06 |
Sent To |
P |
|
| Notes |
| 2002-05-17 00:00:00 | *************** UNSAT ************* | | | ***** NO REVIEW TO BE DONE, SEPARTE | | | PLANS TO BE SUBMITTED WITH AN ELECTRICAL | | | PERMIT APPLICATION. | | | | | | | | | 1)NOTE: PLEASE NOTE THAT PANEL SCHEDULE | | | AND LOAD CALCULATIONS, DO NOT CORRELATE. | | | PLEASE NOTE MIN AND MAX OCP WITH MANY | | | ITEMS ON PANEL SCHEDULE NEED TO BE | | | ADDRESSED. PLEASE NOTE MANY OTHER NEC | | | ISSUES. | | | PLEASE SUBMIT A NEW SETWITH ELECTRICAL | | | CONTRACTOR./PERMIT APPLICATION. | | | | | | IF THERE ARE ANY QUESTIONS, OR IF A | | | MEETING IS NEEDED, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-25 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-25 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2002-04-25 00:00:00 | ***************REVISION NEEDED ********* | | | | | | 1)NOTE: PLEASE NOTE THAT THERE ARE | | | EQUIPMENT GROUNDING CONDUCTORS SHOWN | | | BETWEEN METER AND FIRST MEANS OF DISC. | | | PLEASE NOTE THAT THIS IS PARALLELING THE | | | NEUTRAL WHICH IS NOT PERMITTED. | | | | | | 2)NOTE: PLEASE NOTE MISSING EQUIPMENT | | | GROUND BETWEEN MAINS AND DISC`S 250-122. | | | | | | | | | 3)NOTE: PLEASE NOTE MISSING SD`S UP AND | | | DOWN STAIRS TO BE IN CLOSE PROXIMITY AND | | | LEADING TO THE FLOOR ABOVE. 2-2.1.1.1, | | | 2-5.2.1.4 | | | | | | 4)NOTE: PLEASE NOTE THAT THE SERVICE | | | ENTRANCE CONDUCTOR ARE SHOWN AS ONE | | | SIZE ON SHEET 10 AND ANOTHER ON SHEET | | | 11? PLEASE CORRELATE PLANS FOR THE | | | CONDUCTOR SIZES. | | | | | | 5)NOTE: PLEASE NOTE MISSING OUTLET | | | LOWER LEVEL.210-52 | | | | | | PLEASE REVISE THE ABOVE AND SUBMIT FOR | | | REVIEW BEFORE FINAL ELEC INSPECTION IS | | | CALLED IN. IF THERE ARE NAY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-04-01 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-03-27 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-02-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-02-26 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-02-26 |
Time |
16:59 |
Sent To |
R |
|
| Notes |
| 2002-02-26 00:00:00 | ***************UNSAT!******************* | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION AND RESUBMIT FOR REVIEW: | | | | | | 1) AN A.I.C. RATING TO THE FIRST MEANS | | | OF DISCONNECT AND INDICATE THE RATING | | | OF OCP FOR SAME. | | | | | | 2) INDICATE THE LOCATION OF THE SERVICE | | | ON THE PLAN. | | | | | | 3) INDICATE PANEL LOCATIONS ON PLAN,ALSO | | | SIZE AND TYPE OF RACEWAYS AND | | | CONDUCTORS FEEDING SAME.(CONDUITS | | | LEAVING PANELS "A" & "B" ARE NOTED AS | | | GOING "TO HOUSE SERVICE",PLEASE | | | CLARIFY.) | | | | | | 4) THERE ARE NO BATH ROOM G.F.I'S ON | | | PANEL SCHEDULES ( OR ADDED TO LOAD | | | CALCULATIONS) AS PER 210-11(C)(3). | | | | | | 5) THE WATER HEATER CIRCULATING PUMP IS | | | NOT SHOWN ON PANEL SCHEDULE. | | | | | | 6) WATER HEATER IS LISTED AT 1.5 | | | KW.,PLEASE CONFIRM. | | | | | | 7) OVEN IS LISTED AT 1.5KW.PLEASE | | | CONFIRM.A GAS COOKTOP IS SHOWN ON PLAN, | | | AND A 8 KW. RANGE.PLEASE CLARIFY WHAT | | | APPLIANCES ARE BEING INSTALLED AND THE | | | CORRECT NAME PLATE RATING FOR SAME. | | | | | | 8) PANEL "B" LOAD CALCS SHOW 3 AHU'S AT | | | 10KW'S EACH.AIR HANDLER CALCS SHOW A | | | TOTAL OF 20KW'S FOR THESE THREE | | | UNITS.PLEASE CORRECT. | | | | | | 9) ACCU'S #1,2,&3 ARE LISTED ON 40 AMP | | | BREAKERS PROTECTING #10 WIRE.CLARIFY. | | | | | | 10) THE WATER HEATER LISTED ON PANEL"B" | | | IS SHOWN ON A SINGLE POLE BREAKER,BUT | | | LISTED ON CIRCUITS 10 & 12. | | | | | | 11) THE DRYER LISTED ON PANEL"A"IS SHOWN | | | ON CIRCUIT #2.IT IS ALSO SHOWN AS 8KW. | | | | | | 12) KITCHEN COUNTER TOP RECEPTACLES PER | | | 210-52(C)(1). | | | | | | 13) PLEASECHECK RECEPTACLE LOCATIONS | | | TO COMPLY WITH 210-52(A)(2)(A).SEE | | | PLANS. | | | | | | 14) PLEASE NOTE SMOKE DETECTOR | | | LOCATIONS AND COMPLY WITH NFPA-72. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/ 659-8096 EXT.8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-03-19 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-19 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-19 |
Time |
11:10 |
Sent To |
E |
|
| Notes |
| 2003-03-19 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-26 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-26 |
Time |
09:12 |
Sent To |
B |
|
| Notes |
| 2003-02-26 00:00:00 | REV TO LOU HATTEN'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-18 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-18 |
Time |
11:39 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-30 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-27 |
Time |
17:03 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-12-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-24 |
Time |
15:17 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2002-12-24 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2002-12-24 00:00:00 | MECH PERMIT 02061884/REVISION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-05-16 |
Time |
16:02 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-05-16 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2002-05-16 00:00:00 | NO MECHANICAL PERMIT NUMBER ON | | | APPLICATION | | | H.M. 5/16/02 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-02-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-02-23 |
Time |
10:38 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2002-02-23 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2002-02-23 00:00:00 | PLAN DENIED | | | #1 NO MECHANICAL PLANS | | | #2 NO MANUAL J | | | PLAN REVIEW BY HAROLD MOSER | | | [561]659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-03-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-01 |
Time |
06:27 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-03-01 |
Time |
06:27 |
Sent To |
|
|
| Notes |
| 2003-03-01 00:00:00 | REVISION OK - BAR SINK CHANGED TO FUTURE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2003-02-28 |
Time |
18:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-02-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-24 |
Time |
13:39 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-02-03 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2003-02-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT 11 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE OR REFLECT FLOOR PLAN. | | | A) BATH #2 FROM THE SECOND FLOOR SHALL | | | NOT TIE INTO DRAIN BETWEEN THE W/C AND | | | THE LAV (VENT FOR POWDER ROOM) IN THE | | | POWDER ROOM. | | | B) BATH #2 SHOWS A SHOWER ON THE RISER | | | DIAGRAM, BUT IS REMOVED ON FLOOR PLAN. | | | PLEASE CLAIRFY. | | | C) BAR SINK SHALL NOT DRAIN INTO THE | | | WET VENT FOR BATHROOM #4. SINK SHALL TIE | | | IN DOWN STREAM OF THE BATHROOM GROUP. | | | SECTION 909.1. | | | | | | PLEASE MAKE CHANGES AND RESUBMIT. | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-03 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-17 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-17 |
Time |
06:07 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2002-04-01 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2002-04-01 00:00:00 | PROVISO; | | | AS BUILT RISER DIAGRAM REQUIRED BERORE | | | FINAL PLUMBING INSPECT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-02-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-02-23 |
Time |
10:16 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2002-02-23 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2002-02-23 00:00:00 | 1.PLUMBING RISER NOT TO CODE; | | | A.BAR SINK (2) NOT VENTED. | | | B.SECOND FLOOR SHOWERS (4" RISER) | | | NOT VENTED. WATER CLOSET FLUSHING | | | PAST SHOWERS. | | | C.LAUNDRY TUB NOT VENTED. | | | 2.SHOCK ARRESTORS TO COMPLY WITH 94 SPC | | | SEC. 607.8.2. | | | 3.SEPORATE PERMIT AND PLANS REQUIRED | | | FOR GAS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2002-04-07 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2002-04-07 |
Time |
15:18 |
Rev Time |
2.50 |
| Received By |
lhatten |
Date |
2002-04-07 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2002-04-09 00:00:00 | 3RD SET REVIEW & STAMPED PLANS | | | 04/07/2002 | | | SAME AS ABOVE |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2002-03-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-03-03 |
Time |
17:12 |
Rev Time |
2.50 |
| Received By |
lhatten |
Date |
2002-03-03 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2002-03-22 00:00:00 | REVIEW & STAMPED PLANS 03/03/2002 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-02-21 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-02-21 |
Time |
14:43 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2001-09-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-09-05 |
Time |
09:17 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|