Plan Review Details - Permit 01081223
Plan Review Stops For Permit 01081223
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-11-14 Time 07:47 Rev Time 0.50
Received By btrobaug Date 2002-11-14 Time 06:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-17 Cont ID  
Sent By dpalmer Date 2002-06-17 Time 15:22 Rev Time 0.00
Received By dpalmer Date 2002-06-17 Time 15:22 Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-09-07 Cont ID  
Sent By rmcdouga Date 2002-06-14 Time 18:36 Rev Time 0.00
Received By dpalmer Date 2001-09-07 Time 12:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-25 Cont ID  
Sent By dpalmer Date 2003-02-25 Time 11:29 Rev Time 0.00
Received By dpalmer Date 2003-02-25 Time 11:29 Sent To P
Notes
2003-02-25 00:00:00TO PLUMB INBOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-06-14 Cont ID  
Sent By pkrauss Date 2002-06-14 Time 07:42 Rev Time 0.35
Received By pkrauss Date 2002-06-14 Time 07:38 Sent To R
Notes
2002-06-14 00:00:00PROVISO:MECHANICAL PERMIT 01090348
  
 BALANCED RETURN AIR - 2001 FBC(M) 601.4
 RETURN AIR SHALL BE EQUAL TO SUPPLY
 AIR BY MEANS OF AIR TRANSFER OR A RETURN
 AIR (JUMPER).
  
 SHOULD DRYER BE A GAS APPLIANCE -
 SHOW COMPLIANCE FOR COMBUSTION AIR AS
 PER 2001 FBC(M) CHAPTER 7.
  
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS
 WITH NOTIFICATION TO ALARM/STOBE OR AREA
 SMOKE DETECTORS. 2001 FBC(M) 606.4.1
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2002-05-08 Cont ID  
Sent By pkrauss Date 2002-05-08 Time 16:29 Rev Time 0.35
Received By pkrauss Date 2002-05-08 Time 16:29 Sent To R
Notes
2002-05-08 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLAN SHEET C-1 INDICATE PLANS
 ARE DESIGNED TO THE 2001 FBC. MECHANICAL
 PERMIT WAS APPROVED UNDER THE 1997 SMC.
 MECHANICAL PLANS SHALL BE DESIGNED UNDER
 THE SAME CODE AS THE BUILDING CODE (1997
 SBC OR THE 2001 FBC)
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-09-05 Cont ID  
Sent By kstevens Date 2002-05-07 Time 07:29 Rev Time 0.33
Received By hmoser Date 2001-09-05 Time 17:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-03-01 Cont ID  
Sent By kstevens Date 2003-03-01 Time 13:00 Rev Time 0.50
Received By kstevens Date 2003-03-01 Time 13:00 Sent To  
Notes
2003-03-01 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-05-07 Cont ID  
Sent By dpalmer Date 2003-02-25 Time 11:31 Rev Time 0.00
Received By kstevens Date 2002-05-07 Time 07:29 Sent To M
Notes
2002-05-07 00:00:00DENIED
  
 1) RISER DIAGRAM DOES NOT REFLECT FLOOR
 PLAN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-08-29 Cont ID  
Sent By jleech Date 2001-08-29 Time 19:53 Rev Time 0.25
Received By jleech Date 2001-08-29 Time 19:53 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-06-14 Cont ID  
Sent By rmcdouga Date 2002-06-14 Time 18:36 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To E
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-05-02 Cont ID  
Sent By pkrauss Date 2002-06-14 Time 08:07 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-05-02 00:00:00BUILDING REVISION DENIED
  
 1) ADDITIONAL IMPACT FEES MAY BE DUE TO
 PALM BEACH COUNTY. REVISED PLANS MUST BE
 REVIEWED BY THE COUNTY, STAMPED BY THEM
 AND A COPY OF THE RECIEPT SUBMITTED TO
 THE CITY OF WPB BEFORE THE REVISION CAN
 BE APPROVED.
  
 2) REVISED ENERGY CALCULATIONS AND
 MANUAL "J" CALCULATIONS ARE REQUIRED.
  
 3) THE ORIGINAL PLANS WERE DESIGNED
 USING THE 1997 SBC CRITERIA AND 110 MPH
 WIND SPEED. THE REVISION IS USING THE
 2001 FBC AND A 140 MPH WIND SPEED. THE
 REVISION MUST USE THE SAME DESIGN
 CRIETRIA AS THE PERMITTED PLANS.
  
 4) THE PLAN NOTES, FRAMING NOTES AND
 FOUNDATION NOTES ON C1 HAVE BEEN CHANGED
 FROM THE APPROVED PLANS.
  
 5) PROVIDE PRODUCT APPROVALS FOR THE
 MULLIONS CONNECTING THE 16' SLIDING
 GLASS DOOR AND FIXED GLASS WINDOWS AT
 THE GREAT ROOM OR PROVIDE ENGINEERING
 FOR THIS ASSEMBLY.
  
 7) PROVIDE REVISED KEY PLAN AND
 INSTALLATION SCHEDULE FOR STORM PANELS.
  
 8) THE EGRESS WINDOW AT THE PROPOSED DEN
 EXCEEDS THE OPENING AREA ALLOWED BY
 TABLE 600 OF THE 97 SBC. BASED ON THE
 DISTANCE TO THE PROPERTY LINE 20 PERCENT
 OF THE WALL AREA (20.68 SQFT.)IS ALLOWED
  
 9) DETAIL 6 ON A5 INDICATES A 45 DEGREE
 OFFSET HANGER. DUE TO THE REVISION THE
 WALL IS NO LONGER ON A 45. PLEASE REVISE
 HANGER.
  
 10) THE UPLIFT VALUES FOR THE TRUSSES ON
 A6 FOR THE REVISION HAVE HIGHER VALUES
 DUE TO THE DIFFERENT DESIGN CRITERIA
 THAT WAS USED. PLEASE CORRECT.
  
 11) THE UPLIFT VALUES FOR THE GIRDER
 TRUSS AT THE MASTER BEDROOM ARE SHOWN ON
 THE WRONG TRUSS.
  
 12)THE PA 28 ANCHORS INDICATED IN DETAIL
 11 ON A5 IS NOT DESIGNED TO BE USED AS A
 TRUSS ANCHOR WHERE RESISTANCE TO LATERAL
 FORCES IS REQUIRED. PLEASE REVIEW.
  
 ADDITIONAL FEES WILL BE REQUIRED FOR
 ADDITIONAL AREA.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-09-22 Cont ID  
Sent By rmcdouga Date 2001-09-22 Time 08:36 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-09-22 00:00:00************BUILDING PROVISO************
  
 1) THE HORIZONTAL MULLION ABOVE THE
 SLIDING GLASS DOOR EXCEEDS THE VALUES
 LISTED IN THE PRODUCT APPROVALS THAT
 WERE SUBMITTED. PLEASE PROVIDE PRODUCT
 APPROVALS OR ENGINEERING FOR THE SLIDING
 GLASS DOOR AND WINDOW ASSEMBLY PRIOR TO
 INSTALLATION.
  
 2) THE PRODUCT APPROVALS SUBMITTED FOR
 THE SINGLE HUNG WINDOWS EXPIRED PRIOR TO
 APPLYING FOR PERMIT. PLEASE PROVIDE
 CURRENT PRODUCT APPROVALS FOR SH WINDOWS
 PRIOR TO INSTALLATION.

Review Stop Z ZONING
Rev No 3 Status P Date 2002-06-20 Cont ID  
Sent By sgraham Date 2002-06-20 Time 16:35 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2002-05-02 Cont ID  
Sent By dpalmer Date 2002-06-17 Time 15:22 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-05-02 00:00:00REVISION OK PER S.GRAHAM 5-2-02

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-28 Cont ID  
Sent By sgraham Date 2001-08-28 Time 13:43 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***