| Plan Review Stops For Permit 01081166 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-09-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-13 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-10-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-22 |
Time |
19:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-22 |
Time |
19:36 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-10-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-09 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-09 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2001-10-09 00:00:00 | ************** UNSAT ****************** | | | | | | PLEASE NOTE THAT NOT ALL NOTES FROM | | | FIRST REVIEW WERE ADDRESSED. PLEASE SEE | | | THE FOLLOWING NOTES. | | | | | | 1)NOTE: PLEASE NOTE THAT NOW A NEW | | | ELECTRICAL RISER DIAGRAM IS BEING SUB- | | | -MITTED? PLEASE NOTE THAT LOAD CALCS DO | | | NOT SHOW WATTS/ PER SQ FT PER 220? | | | PLEASE NOTE THAT A 400AMP SERVICE IS | | | BEING INSTALLED W/ 200AMPS WORTH OF | | | WIRE AND LOAD ALREADY AT 192AMPS.??? | | | PLEASE CLARIFY AND SHOW. | | | | | | 2)NOTE: PLEASE NOTE THAT BRANCH CIRCUIT | | | #`S ARE STILL NOT SHOWN ON PLANS ,THAT | | | CORRELATE WITH PANEL SCHEDULES. | | | | | | 3)NOTE: PLEASE CLARIFY WHICH OUTLETS | | | INFRONT ARE SHOW WINDOW AND WALL OUTLETS | | | ?? PLEASE CLARIFY. | | | | | | 4)NOTE:PLEASE CLARIFY SIGN CIRCUIT PER | | | 600-5A? | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-30 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-30 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2001-08-30 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT ALL BRANCH | | | CIRCUIT #`S NEED TO BE SHOWN ON PLANS | | | AND CORRELATE W/ PANEL SCHEDULE THAT | | | NEEDS TO BE SUBMITTED. | | | | | | 2)NOTE: PLEASE SHOW ELECTRICAL | | | EQUIPMENTAND/OR EXSITING ELEC. | | | | | | 3)NOTE: PLEASE NOTE MISSING OUTLETS FOR | | | SHOW WINDOWS PER 210-62 AND 220-3B-7 | | | | | | 4)NOTE: PLEASE NOTE MISSING SIGN | | | CIRCUITPER 220-3B-6 AND 600-5A | | | | | | 5)NOTE: PLEASE CLARIFY LIGHTING? NONE | | | SHOWN? EXISTING? PLEASE SHOW | | | | | | 6)NOTE: PLEASE NOTE OUTLET SPACING TO | | | MEET LOCAL CODE. 210-50 | | | 12'OFFICE AND 20' OF OTHER AREAS. | | | | | | 7)NOTE: PLEASE NOTE THAT NO EXIT | | | LIGHTING AND/OR EMERGENCY LIGHTING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-10-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-29 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-29 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-23 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-23 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2001-08-23 00:00:00 | 1) PLEASE CLEARLY INDICATE ILLUMINATED | | | EXIT SIGNS AND EMERGENCY LIGHTING | | | EQUIPMENT WITHIN TENANT SPACE. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2001-11-09 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2001-11-09 |
Time |
09:57 |
Rev Time |
1.00 |
| Received By |
rbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-09 00:00:00 | MECHANICAL CONTRACTOR WILL SUBMIT | | | SEPERATE PLANS AND APPLICATION FOR | | | PERMIT, L.MARTINEZ11/9/01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-10-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-25 |
Time |
11:03 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-10-25 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2001-10-25 00:00:00 | *******************DENIED*************** | | | | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW.PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | | 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-07 |
Time |
15:30 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-09-07 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2001-09-07 00:00:00 | *******************DENIED*************** | | | | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW.PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2002-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-01-09 |
Time |
13:22 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-01-09 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2002-01-09 00:00:00 | REVISION APPROVED - RISER DIAGRAM - | | | HDCP TOILET ROOMS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-11-08 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-11-08 |
Time |
18:03 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-08 00:00:00 | RESUB 4TH TIME, OK PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-10-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-10-23 |
Time |
19:42 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-10-23 |
Time |
19:42 |
Sent To |
|
|
| Notes |
| 2001-10-23 00:00:00 | DENIED; | | | | | | THIRD REQUEST; | | | PLEASE COMPLY WITH FACBC-97 SEC. 4.24. | | | SHOW COUNTER HEIGHT, KNEE CLEARANCE AND | | | CLEAR FLOOR SPACE. SHOW DETAILS OF ALL | | | REQUESTED INFORMATION. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-22 |
Time |
19:36 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-10-11 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2001-10-11 00:00:00 | DENIED | | | REFERENCE: FACBC-97 | | | | | | 1) COMMENT FROM PREVIOUS REVIEW NOT | | | ADDRESSED. PLEASE COMPLY WITH FACBC-97 | | | SEC 4.24. SHOW COUNTER HEIGHT 4.24.2, | | | KNEE CLEARANCE SEC 4.24.3, AND CLEAR | | | FLOOR SPACE 4.24.5. SHOW DETAILS OF | | | ALL REQUESTED INFORMATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-09-05 |
Time |
16:20 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
|
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2001-09-05 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) PLEASE SHOW CLEAR FLOOR SPACE FOR | | | SINK IN LOUNGE. SHOW SIDE OR FRONTAL | | | APPROACH. PLEASE COMPLY WITH FACBC-97 | | | SECTION 4.24. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-11-09 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2001-11-09 |
Time |
10:00 |
Rev Time |
1.00 |
| Received By |
rbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|