| Plan Review Stops For Permit 01081084 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-05-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-08 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-05-08 |
Time |
14:53 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-11 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-11 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-09-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-10 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-10 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2001-09-10 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO,DURING AND AFTER CONSTRUCTION. | | | 2) BUILDING ADDRESSES REQUIRED. | | | 3) ELECTRIC POWERED SMOKE DETECTORS | | | REQUIRED. | | | 4) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-01-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-29 |
Time |
16:11 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-01-29 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2002-01-29 00:00:00 | MECH REV PERMIT 01081103 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-09-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-29 |
Time |
10:24 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2001-09-29 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-09-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-28 |
Time |
10:10 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2001-09-28 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-09-06 |
Time |
18:23 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2001-09-06 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2001-09-06 00:00:00 | DENIED | | | NO A/C PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-09-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-08 |
Time |
17:12 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2001-09-06 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2001-09-06 00:00:00 | PROVISO; | | | 1.W/C SHALL BE 18" OFF TUB OR SHOWER. | | | SEE FHA 7.43. PLEASE REVISE DRAWINGS | | | TO MEET FHA REQUIRERMENTS. | | | 2.PAGE 2 PLUMBING RISER DIAGRAMS. 1527-L | | | AND R, OPT. LT SHALL HAVE A VENT, JUST | | | LIKE WET BAR AND BBQ SINK. | | | 3.1409 L AND R SAME AS PLAN REVIEW NOTE | | | TWO. | | | | | | PLUMBING PLAN REVIEW BY | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-10-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-10-01 |
Time |
19:24 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-10-02 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2001-10-01 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE AO. WILL NEED TO PROVIDE | | | ELEVATION CERTIFICATE. | | | 2-NEED ADDITIONAL BORINGS FOR EACH | | | STRUCTURE AS RECOMMENDED BY THE PRE- | | | LIMINARY SUBSURFACE STUDY. | | | 3-ENGINEER OF RECORD TO COMPLETE THE | | | DESIGN CERTIFICATION FOR BUILDING CODE | | | COMPLIANCE FORM. | | | 4-PROVIDE COMPLETE INFORMATION FOR STORM | | | PANELS UNDER A SEPARATE PERMIT. | | | 5-PROVIDE PRODUCT APPROVAL FOR WINDOW | | | MULLIONS (TWO COPIES). | | | | | | | | | | | | | | | NOTES: | | | -DRAWINGS TO BE FILED UNDER PERMIT # | | | 01081084. | | | -THESE COMMENTS APPLY TO PERMIT #S: | | | 01081084, 01081094, 01081098 AND | | | 01081088. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-09-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-09-15 |
Time |
12:38 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-09-15 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2001-09-15 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES. | | | 2-RECORD NOTICE OF COMMENCEMENT. | | | 3-NEED TO REVISE ORIGINAL DRAWINGS TO | | | REFLECT THE RIGHT DIMENSIONS REQUIRED | | | FOR THE PLUMBING FIXTURES. THIS WILL | | | HELP EXPEDITE THE REVIEW PROCESS FOR | | | FUTURE SUBMITTALS AS WELL. | | | 4-PROVIDE TWO COPIES OF THE PRELIMINARY | | | SUBSURFACE STUDY. | | | -ALSO, WILL NEED TO PROVIDE ADDITIONAL | | | BORINGS FOR EACH STRUCTURE (BEFORE | | | CONSTRUCTION) AS RECOMMENDED IN THE | | | PRELIMINARY STUDY. | | | 5-ENGINEER TO FILL OUT THE DESIGN | | | CERTIFICATION FOR BUILDING CODE | | | COMPLIANCE FORM. PLEASE, AVOID FUTURE | | | DELAYS. THIS FORM IS MISSING IN EVERY | | | SUBMITTAL I HAVE REVIEWED. | | | 6-OWES ADDITIONAL FEES FOR UPDATED | | | VALUATION AND RADON FEES. PLEASE, PAY | | | ATTACHED RECEIPTS. | | | 7-CLEARLY INDICATE ON PLANS THE OPTIONS | | | SELECTED AND PROVIDE THE CORRESPONDING | | | PRODUCT APPROVAL OR CROSS OUT THE | | | OPTIONS IF NOT USED. | | | 8-SEE COMMENTS BY THE PLUMBING PLAN | | | EXAMINER AND PROVIDE A/C PLANS FOR | | | MECHANICAL PLAN EXAMINER REVIEW. | | | 9-PROVIDE COMPLETE INFORMATION FOR STORM | | | PANELS UNDER A SEPARATE PERMIT. | | | 10-PROVIDE 2 COPIES OF PRODUCT APPROVAL | | | FOR WINDOW MULLIONS. | | | NOTES: | | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | | PERMIT NUMBER 01081084. | | | -THESE COMMENTS APPLY TO PERMIT #S: | | | 01081084, 01081094, 01081098 AND | | | 01081088. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-08-30 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-08-30 |
Time |
14:33 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|