Plan Review Stops For Permit 01081013
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-09-20 Cont ID  
Sent By lmartine Date 2001-09-20 Time 11:04 Rev Time 2.00
Received By lmartine Date   Time   Sent To  
Notes
2001-09-20 00:00:00PROVISO
 -------
  
 SUBMIT PRODUCT TESTING FOR APPROVAL FOR
 ALL EXTERIOR GLAZING AND DOORS. COMPLY
 WITH WINDLOADS AND MISSILE IMPACT.
  
  
 L.MARTINEZ
 659-8096
 #8456

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2001-10-04 Cont ID  
Sent By dpalmer Date 2001-10-04 Time 09:57 Rev Time 0.00
Received By dpalmer Date 2001-10-04 Time 09:57 Sent To  
Notes
2001-10-04 00:00:00************** NOTE**********
  
 PLANS PULLED FROM ELECTRICAL PLAN
 REVIEW. PLANS TO BE SUBMITTED SEPARATELY
 FOR ELEC PER CONTRACTOR, RAY DEVIO.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2001-10-03 Cont ID  
Sent By dpalmer Date 2001-10-03 Time 09:57 Rev Time 0.00
Received By dpalmer Date 2001-10-03 Time 09:56 Sent To  
Notes
2001-10-04 00:00:00SAME NOTES AS BEFORE.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-09-24 Cont ID  
Sent By dpalmer Date 2001-09-24 Time 18:50 Rev Time 0.00
Received By dpalmer Date 2001-09-24 Time 18:50 Sent To  
Notes
2001-09-24 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE NOTE THAT IF THE SHOW
 WINDOW WAS THE ONLY ISSUE, THE PLANS
 COULD HAVE BEEN REDLINED.
 PLEASE NOTE THAT ALL CHANGES TO SIGNED
 AND SEALED PLANS, ARE TO BE DONE BY THE
 ENGINEER OF RECORD PER FS/ FAC. 471.025
  
 2)NOTE: PLEASE NOTE THAT 600-5, LETTER
 MENTIONS TENANT AJACENT TENANTS,??
 PLEASE CALRIFY HOW THIS MEETS 600-5.
  
 3)NOTE: PLEASE NOTE THAT THE LOAD CALCU-
 -LATIONS THAT WERE SUBMITTED ON SHEET 6
 WERE NOT COMPLETE AND SHOWN PER ART220.
 PLEASE SHOW.215-5 TRACK LIGHTING 220-12B
 NOTE CIRCUIT ADDED FOR SHOW WINDOW, NOT
 SIGNED PER ENG OF REC.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. PLEASE NOTE THAT PLANS WERE
 COMING BACK FOR OTHER COMMENTS.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-09-18 Cont ID  
Sent By dpalmer Date 2001-09-18 Time 21:31 Rev Time 0.00
Received By dpalmer Date 2001-09-18 Time 21:31 Sent To  
Notes
2001-09-18 00:00:00************** UNSAT *******************
  
 1)NOTE: PLEASE NOTE THAT COMPLETE LOAD
 CALCUALTIONS WERE NOT SUBMITTED> PLEASE
 SHOW! INCLUDING SQ FTETC. PER 220
 PLEASE SHOW TRACK LIGHTING PER 220-12B
  
 2)NOTE: PLEASE NOTE MISSING SHOW WINDOW
 RECEPTS PER 210-62/ LOADS PER 220-12A
  
 3)NOTE: PLEASE NOTE/CLARIFY SIGN CIRCUIT
 PER 600-5.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-09-20 Cont ID  
Sent By lmartine Date 2001-09-20 Time 07:26 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-09-24 Cont ID  
Sent By mcarsill Date 2001-09-24 Time 15:31 Rev Time 0.00
Received By mcarsill Date 2001-09-24 Time 15:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-08-28 Cont ID  
Sent By mcarsill Date 2001-08-28 Time 15:21 Rev Time 0.00
Received By mcarsill Date 2001-08-28 Time 15:21 Sent To  
Notes
2001-08-28 00:00:001) PLANS NOT SIGNED AND SEALED. PLANS
 CONTAIN ARCHITECHT'S TITLE BLOCK.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-09-20 Cont ID  
Sent By pkrauss Date 2001-09-20 Time 08:41 Rev Time 0.30
Received By pkrauss Date 2001-09-20 Time 08:32 Sent To  
Notes
2001-09-20 00:00:00 
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.
  
 PLEASE SUBMIT PLANS WITH MECHANICAL
 PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096 EXT.
 8388.

Review Stop P PLUMBING
Rev No 4 Status P Date 2001-10-16 Cont ID  
Sent By kstevens Date 2001-10-04 Time 11:24 Rev Time 0.00
Received By kstevens Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-09-27 Cont ID  
Sent By kstevens Date 2001-09-27 Time 10:27 Rev Time 0.33
Received By kstevens Date 2001-09-27 Time 10:27 Sent To  
Notes
2001-09-27 00:00:00DENIED
 REFERENCE SPC-94
  
 PLEASE ADDRESS PREVIOUS COMMENTS FROM
 PAST REVIEWS. PRIMARY AND SECONDARY ROOF
 DRAINAGE FOR EXISTING ROOF WITH CALCULA-
 TIONS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-09-22 Cont ID  
Sent By pschmitz Date 2001-09-22 Time 13:16 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-09-22 00:00:00PLUMBING PLAN REVIEW, DENIED
 PLEASE ADDRESS PREVIOUS COMMENTS DATED
 09-05-01.
 SHOW PRIMARY AND SECONDARY ROOF DRAINAGE
 WITH CALCULATIONS,FOR THE EXISTING ROOF,
 SIZES OF ROOF DRAINS AND SCUPPERS
 THIS PERMIT IS FOR STORE FRONT ADDITION,
 INTERIOR DEMOLITION AND BUILT-UP ROOF.
 END OF COMMENT PAUL SCHMITZ
 QUESTIONS 561-659-8096X8233

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-09-05 Cont ID  
Sent By kstevens Date 2001-09-05 Time 13:48 Rev Time 1.75
Received By kstevens Date 2001-09-05 Time 13:48 Sent To  
Notes
2001-09-05 00:00:00DENIED
 REFERENCE SPC-94
 REVIEW FOR THIS PERMIT PER PAGE #1,
 THE ONLY PLUMBING WILL BE FOR ROOF
 DRAINS, SECONDARY ROOF DRAINS, AND
 RELATED PIPING.
 1) PLEASE SUBMIT A STORM RISER DIAGRAM,
 AND ROOF DRAIN, AND SECONDARY DRAIN
 CALCULATIONS FOR NEW ROOF. PLEASE USE
 SPC SEC. 1108, AND 1109.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-28 Cont ID  
Sent By sgraham Date 2001-08-28 Time 11:24 Rev Time 0.25
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***