Plan Review Details - Permit 01080862
Plan Review Stops For Permit 01080862
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-02 Cont ID  
Sent By jwitmer Date 2001-10-02 Time 16:42 Rev Time 0.50
Received By jwitmer Date 2001-10-02 Time 16:42 Sent To  
Notes
2001-10-02 00:00:00BUILDING PLAN REVIEW
 PRMIT # 01080862
 5809 CHURCHILL
 O/B FUENTES ORALIA
  
 SBC= 1997 STANDARD BUILDING CODE
  
 1)- SBC 3401.2.2.1 CHANGE OF OCCUPANCY:
 IF THE OCCUPANCY CLASSIFICATION OF ANY
 EXISTING BUILDING OR STRUCTURE IS
 CHANGED, THE BUILDING, ELECTRICAL, GAS,
 MECHANICAL AND PLUMBING SYSTEMS SHALL BE
 MADE TO CONFORM TO THE REQUIREMENTS OF
 THE TECHNICAL CODES FOR NEW CONSRUCTION.
  
 2)-THIS BUILDING WAS ORIGINALLY A STOR-
 AGE SHED, TO CONVERT IT TO A RESIDETIAL
 UNIT PLAANS WILL NEED TO BE DRAWN THAT
 COMPLY WITH THE 1997 STANDARD BUILDING
 CODE OR SBC SSTD-1099 STANDARD FOR HURRI
 CANE RESISTANT RESIDENTIAL CONSTRUCTION.
 PLANS ARE TO DEPICT THE FOUNDATION, AN-
 CHORING SYSTEM,STRAPPING THROUGHOUT,
 FROM FOUNDATION TO THE RAFTERS.
 INDICATE THE COMPLETE SUB PERMIT SYSTEMS
 ELEC,PLUMBING & MECHANICAL, ENERGY CALCU
 LATIONS, SINCE THIS IS A CHANGE OF OCCUP
 ANCY, INDICATE HOW YOU WILL MEET THE RE-
 QUIREMENTS FOR LARGE MISSLE IMPACT RESIS
 TANCE FOR GLAZED OPENINGS.
  
 ONCE PLANS ARE APPROVED YOU WILL NEED TO
 TAKE THE PLANS TO THE COUNTY BUILDING
 DEPARTMENT TO BE ASSESSED FOR IMPACT
 FEES.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-09-15 Cont ID  
Sent By kstevens Date 2001-09-15 Time 16:35 Rev Time 0.33
Received By kstevens Date 2001-09-15 Time 16:35 Sent To  
Notes
2001-09-15 00:00:00DENIED
 REFERENCE: SPC-94
  
 LAV AND SHOWER NOT VENTED PROPERLY.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-18 Cont ID  
Sent By jleech Date 2001-08-18 Time 10:33 Rev Time 0.30
Received By jleech Date 2001-08-18 Time 10:33 Sent To  
Notes
2001-08-18 00:00:00DENIED;
 1.SHOW RISER DIAGRAM AND SIZE ALL PIPE.
 2.LINE DRAWING NOT TO CODE.
 3.3" VENT REQUIRED PER STANDERD PLUMBING
 CODE. SEC. 904.3.1.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-28 Cont ID  
Sent By sgraham Date 2001-08-28 Time 11:38 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-08-28 00:00:00NO RENTAL, NO KITCHEN, BLDG CAN NOT
 USED AS AN APARTMENT.