Plan Review Details - Permit 01080716
Plan Review Stops For Permit 01080716
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-11-21 Cont ID  
Sent By jwitmer Date 2001-11-21 Time 07:34 Rev Time 1.00
Received By jwitmer Date 2001-11-21 Time 07:34 Sent To  
Notes
2001-11-21 00:00:00BUILDING PLAN REVIEW
 11/21/01 ALL COMMENTS HAVE BEEN SATISFI
 ED EXCEPT FOR:
 1) PRODUCT APPROVAL FOR WINDOWS & DOORS
 2) PLANS TO COUNTY FOR IMPACT FEES
 3) STATE RADON FEES $18.00
  
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-11-01 Cont ID  
Sent By jwitmer Date 2001-11-01 Time 09:56 Rev Time 4.00
Received By jwitmer Date 2001-11-01 Time 09:56 Sent To  
Notes
2001-11-01 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01080716
 2815 N FLAGLER DR
 CONT: CASTLE FLORIDA BUILD
 TEL: 272-1207
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
  
 1)- SHEET A-4:
 A) RECEPTION ROOM HAS (2) SETS OF DOUB-
 LE DOORS, D-14 & E.R. (EXISTING DOOR),
 WILL EXISTING DOOR HAVE PANIC HARDWARE.
 B) DOOR D-14 NOTE 32X10 PT HEADER,
 TYPE II CONSTRUCTION, NO WOOD ALLOWED IN
 EXTERIOR WALS.
 C) SBC 1606.2.6.2 COMPONENTS & CLADDING
 WILL REQUIRE (2 COPIES) OF PRODUCT TEST-
 ING REPORTS FOR ALL OPENINGS & ROOFING
 ASSEMBLIES INCLUDED:
 WINDOWS
 DOORS
 ROOFING ASSEMBLIES
 STORM SHUTTERS
 THE CITY ACCEPTS S.B.C.C.I. AND DADE
 COUNTY PRODUCT TESTING REPORTS.
 D) COFFERED CEILING SECTION A 4-5 THERE
 IS NO ACTUAL DETAIL WITH ATTACHMENT TO
 THE BAR JOIST OR WALL NOR IS THERE INFO
 FOR TYPE OF MATERIAL, SPACING ?
  
 SHEETA-5:
 A) SEC. A-A INDICATES GYP. BD. ON HAT
 CHANNEL HUNG FROM THE BAR JOIST, ISN'T
 THE HI-HAT ACTUALLY HUNG FROM 1 1/2 C
 CHANNEL,WITH THE HI HAT TIE WIRED FROM
 THE C CHANNEL? HANGING WIRE SIZE,
 SPACING OF C CHANNEL & OF THE HI-HAT?
 THICKNESS OF THE GYPSUM BOARD?
  
 MISSING INFORMATION SBC TABLE 803.3
 MINIMUM INTERIOR FINISH CLASSIFICATION.
  
 CONTACTOR SHALL HAVE THE PLANS REVIEWED
 FOR ADDITIONAL FEES COUNTY IMPACT FEES.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-09-18 Cont ID  
Sent By hpiskura Date 2001-09-18 Time 13:33 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-09-18 00:00:00BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACG COUNTY, THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.
  
 THIS BUILDING IS TYPE II CONSTRUCTION
 AND THE ADDITION MUST MEET THE SAME
 REQUIREMENTS.SHOW THE FIRE RATINGS IN
 ACCORDANCE WITH TABLE 600 OR PROVIDE A
 FIRE WALL AS DEFINED IN SBC 202.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-09-10 Cont ID  
Sent By dpalmer Date 2001-09-10 Time 22:40 Rev Time 0.00
Received By dpalmer Date 2001-09-10 Time 22:39 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-09-24 Cont ID  
Sent By pkrauss Date 2001-09-24 Time 10:49 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-10-18 Cont ID  
Sent By mcarsill Date 2001-10-18 Time 17:18 Rev Time 0.00
Received By mcarsill Date 2001-10-18 Time 17:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-09-04 Cont ID  
Sent By mcarsill Date 2001-09-04 Time 10:19 Rev Time 0.00
Received By mcarsill Date 2001-09-04 Time 10:19 Sent To  
Notes
2001-09-04 00:00:001) STORAGE ROOM NOT FIRE RATED. SINCE
 NO FIRE SPRINKLERS ARE PLANNED, THIS
 ROOM IS REQUIRED TO BE AT LEAST ONE
 HOUR FIRE RATED. PLEASE DISPLAY THIS
 ONE THE PLANS AND CORRECT THE NON-RATED
 DOOR TO A RATED ONE.
 2) ARE THE DOUBLE DOORS NOTED ER FROM
 THE RECEPTION ROOM EQUIPPED WITH
 PANIC HARDWARE.
 3) PLEASE INDICATE FLAMESPREAD RATINGS
 FOR WALLS AND CEILINGS.
 4) NEW ADDITION TO COMPLY WITH
 REQUIREMENTS FOR NEW OCCUPANCY TYPE.
 5) NO FIRE ALARM EQUIPMENT SHOWN. ARE
 THERE ANY FIRE ALARM EQUIPMENT IN THE
 BUILDING AND IF SO, WHY ARE NONE SHOWN
 FOR THE NEW AREA.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-09-24 Cont ID  
Sent By pkrauss Date 2001-09-24 Time 10:41 Rev Time 0.50
Received By pkrauss Date 2001-09-24 Time 10:41 Sent To  
Notes
2001-09-24 00:00:00PROVISO ON PLAN.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-10-29 Cont ID  
Sent By kstevens Date 2001-10-29 Time 16:25 Rev Time 0.50
Received By kstevens Date 2001-10-29 Time 16:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-09-10 Cont ID  
Sent By kstevens Date 2001-09-10 Time 11:00 Rev Time 1.25
Received By kstevens Date 2001-09-10 Time 13:32 Sent To  
Notes
2001-09-10 00:00:00DENIED
  
 REFERENCE: SPC-94
  
 1) PAGE A7, PLEASE PROVIDE ROOF DRAINAGE
 CALCULATIONS FOR NEW ROOF AREAS. SIZE
 PER SPC-94 SECT 1108 & 1109. PLEASE SHOW
 PRIMARY AND SECONDARY DRAINS ON DETAIL.
  
 2) PAGE A4, PLEASE SHOW CALCULATIONS FOR
 MINIMUM FACILITIES, SPC-94 TABLE 407.
 SHOW HOW NEW BLDGS. IMPACT EXISTING FAC-
 ILITIES AND SHOW HOW THE NEW RECEPTION
 ROOM WILL BE USED. (WILL IT BE ADDING TO
 THE AMOUNT OF PEOPLE USING EXISTING FAC-
 ILITIES?)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-30 Cont ID  
Sent By sgraham Date 2001-08-30 Time 14:20 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***