| Plan Review Stops For Permit 01080701 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-09-17 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-09-17 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-10-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-01 |
Time |
23:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-01 |
Time |
23:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-28 |
Time |
21:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-28 |
Time |
21:25 |
Sent To |
|
|
| Notes |
| 2001-08-28 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT COVER SHEET | | | SHOWS ELECTRICAL UNDER THE "96" NEC. | | | PLEASE NOTE WE ARE UNDER "99" NEC. | | | PLEASE CORRECT. | | | | | | 2)NOTE: PLEASE ALSO NOTE THAT PER | | | CITY OF WEST PALM BEACH LOCAL AMENDMENTS | | | 210-50. OUTLET SPACING TO MEET LOCAL | | | CODE. EVERY 20'FT OF UNENCUMBERED WALL | | | SPACE. | | | | | | 3)NOTE: PLEASE NOTE THAT LOADS FOR TRACK | | | LIGHTING NEEDS TO BE SHOWN PER 220-12B. | | | | | | 4)NOTE: PLEASE CLARIFY THAT ALL | | | ELECTRICAL SHOWN ON SINGLE LINE DIAGRAM | | | IS EXISTING. PANELS SHOWN AS EXISTING, | | | WHAT ABOUT WIRE? PLEASE NOTE THAT THE | | | TAPPED CONDUCTOR FROM DISCONNECT WITH | | | 200A OCP FOR #3. THIS IS OK BUT, #3 | | | NEEDS TO TERMINATE IN A PANEL WITH OCP | | | THAT LIMITS LOAD TO 100AMPS. PLEASE | | | NOTE THAT PANEL IS SHOWN WITH BUS ONLY?? | | | PLEASE NOTE THAT THE #3`S ARE RATED FOR | | | 100A PER 310-16 AND ALSO TERMINATE IN | | | A 125A MCB PANEL"A"?? PLEASE NOTE THAT | | | TAPPED CONDUCTORS NEED TO MEET ART: | | | 240-21 FOR 10' AND 25'. | | | | | | 5)NOTE: PLEASE NOTE THAT PANEL "B " | | | NEEDS TO BE SHOWN ON PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-09-06 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-09-06 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-11 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-11 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2001-10-11 00:00:00 | FS PERMIT # 01090133 ALREADY SUBMITTED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-10-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-10 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-10 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2001-10-10 00:00:00 | COULD NOT LOCATE FIRE SPRINKLER | | | DRAWINGS WITH RE-SUBMITTED PLANS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-20 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-20 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2001-08-20 00:00:00 | 1) NO FIRE SPRINKLER DRAWINGS PROVIDED | | | WITH PLANS. | | | 2) INTERIOR FINISH TO COMPLY WITH | | | STANDARD BUILDING CODE 1997 AND THE | | | LIFE SAFETY CODE, 1985 EDITION. | | | 3) WRONG EDITION OF THE LIFE SAFETY CODE | | | NOTED IN CODES AND ORDINANCES SECTION. | | | SHOULD READ 1985 EDITION OF THE LIFE | | | SAFETY CODE. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-01 |
Time |
09:07 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-10-01 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-07 |
Time |
10:16 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-09-07 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2001-09-07 00:00:00 | *******************DENIED*************** | | | | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW. | | | | | | | | | 1.OUTSIDE AIR CALCULATIONS AS PER | | | ASHRAE 62-89. | | | | | | 2.NO COMBUSTIBLES ABOVE THE CEILING | | | IN THE RETURN AIR PLENUM. | | | 1997 SMC 609.1.1 | | | | | | 3.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | WITH NOTIFICATION TO ALARM/STROBE IN | | | NORMALLY OCCUPIED AREAS. 1997 SMC | | | 406.1 AND NFPA 90A 4-4.4.3. | | | | | | 4.AIR FROM THE RESTROOMS SHALL NOT BE | | | RECIRCULATED AS PER 1997 SMC 503.3.1 | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-15 |
Time |
14:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-10-15 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2001-10-15 00:00:00 | PASSED/PROVISO | | | | | | MINIMUM SIZE FLOOR DRAINS TO BE 3". |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-11 |
Time |
09:16 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-10-11 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2001-10-11 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) FLOOR DRAINS ARE REQUIRED TO BE A | | | MINIMUM OF 3" PER SPC-94 SEC 409.4.1.1. | | | PLEASE CORRECT SIZE OF FLOOR DRAINS AND | | | RESUBMIT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-30 |
Time |
15:24 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2001-08-30 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2001-08-30 00:00:00 | DENIED | | | | | | REFERENCE - SPC-94 - FACBC-97 | | | | | | 1) FLOOR DRAINS ARE REQUIRED IN PUBLIC | | | TOILET ROOMS PER SPC-94 SECT. 409.4.1.1. | | | FLOOR DRAIN SHALL BE EQUIPPED WITH A | | | TRAP PRIMER. PAGE AO.1/P3.1 | | | | | | 2) SANITARY RISER DIAGRAM REQUIRED WITH | | | ALL PIPE SIZES INDICATED. | | | | | | 3) BENCH IN DRESSING ROOM SHALL BE FIXED | | | TO THE WALL WITH THE LONGEST DIMENSION. | | | PAGE A0.1 AND PAGE A7.1 DETAIL #4 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-09-06 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-09-06 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|