| Plan Review Stops For Permit 01080260 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-01-16 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-01-16 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2003-01-16 00:00:00 | THIS PERMIT WAS CLOSED 11/22/02, AND THE | | | DATE ON THE SUBMITTAL IS 12/18/02. | | | ALSO, THE DOORS SHOWN ON SHEET A6 AS | | | 3'-6" DO NOT COMPLY WITH SBC TABLE 1004 | | | FOR GROUP I OCCUPANCY UNRESTRAINED WHICH | | | REQUIRES 44" CLEAR.THE CHANGES MUST | | | BE BY THE DESIGNER OF RECORD AND BEAR | | | HIS EMBOSSED SEAL AND ORIGINAL | | | SIGNATURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2002-07-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-07-31 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-07-31 00:00:00 | REVISION SHEET A17 DATED 5/30/02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2002-05-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-13 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-13 00:00:00 | LONGARC SHOP DWGS FOR STAIR # 159 GARAGE | | | | | | THE STAIRS DO NOT COMPLY WITH SBC 1003.7 | | | REQUIREMENTS FOR THE RISE TO RUN RATIO | | | TO BETWEEN 24" AND 25". |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2002-05-08 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-08 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-08 00:00:00 | REVISION #7 DATED 3/13/02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2001-11-30 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-11-30 |
Time |
15:36 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2001-11-27 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-11-27 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-27 00:00:00 | | | | | | | | | | | | | THE FIRE PROTECTION PLANS ARE REQUIRED | | | TO BE SIGNED AND SEALED | | | | | | IF SOMEONE HAS NOT SPECIFICALLY | | | REQUESTED THAT "VOID" PAGES BE RETAINED | | | IN THE PLANS AND SPECIFICTIONS, I | | | SUGGEST THAT THEY BE REMOVED AS THEY | | | ARE A SOURCE OF CONFUSION AND CLUTTER. | | | | | | SHEET LS-1 DATED 10/4/01 SHOWS A SMOKE | | | BARRIER ALONG GRID LINE L AT THE | | | EXISTING BUILDING.WILL THE TWO | | | PROPOSED WINGS ON THE NORTH END SHOWN | | | WITH "RESIDENTIAL ROOMS" BE REQUIRED TO | | | TRAVEL TO THAT BEGINS NEAR GRID A AND | | | 4?WHAT IS THE DISTANCE?SEE SBC | | | 409.1.2.1. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-10-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-10-16 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
Z |
|
| Notes |
| 2001-10-16 00:00:00 | THE FIRE SPRINKLER PROTECTION SYSTEM | | | DESIGN IS REQUIRED BY FS 553.79 (2) TO | | | BE SUBMITTED WITH THE PERMIT PLANS. | | | | | | THE SPECIFICATIONS BOOKS WERE RETURNED | | | MARKED VOID AND WERE NOT REVIEWED. | | | PROVIDE THREE COPIES OF SIGNED, SEALED | | | AND DATED SPECIFICATIONS SO THAT CODE | | | COMPLIANCE MAY BE DETERMINED. | | | | | | SHEET S1 STILL HAS NOTES LIKE "LATEST | | | EDITION"SEE SBC 3502. | | | | | | THE ROOM SHOWN AS "SOILED UTILITY" IS | | | THAT A SOILED LINEN ROOM?SEE SBC | | | 409.1.2.3. | | | | | | LS1 NOW SHOWS A SMOKE BARRIER NEAR GRID | | | LINE A.IT APPEARS THAT THERE ARE | | | NEITHR PATIENT TREATMENT OR SLEEPING | | | FACILI | | | TIES IN THE AREA CONTAINED IN GRID A - L | | | AND IN THE EXISTING PATIENT AREA THE | | | DISTANCE WOULD EXCEED THE 200' TRAVEL | | | DISTANCE ALLOWED BY SBC 409.1.2.1. | | | PLEASE CLARIFY THE DESIGN INTENT. | | | LARIFY THE DESIGN INTENT. | | | | | | SEE THE 8/31/01 NOTES RE: IMPACT FEES, | | | RESIDENT INSPECTOR, AND PRODUCT/TEST | | | REPORTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-04 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-08-31 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-31 00:00:00 | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.CALL 233-5025 FOR MORE | | | INFORMATION. | | | | | | AS PROVIDED FOR IN SBC 105.3 A RESIDENT | | | INSPECTOR IS REQUIRED FOR A PROJECT OF | | | THIS SCOPE.CONTACT DON NEELY AT | | | 561-659-8096 X 8333 FOR MORE | | | INFORMATION. | | | | | | THIS PROPERTY IS IN A FLOOD ZONE AH BFE | | | 17.0' NGVD. | | | | | | THE FIRE PROTECTION PLANS MUST BE | | | INCLUDED WITH THE PERMIT PLANS.SEE FS | | | 553.79 (2). | | | | | | THE LS PAGES DO NOT CLEARLY INDICATE THE | | | LOCATION OF EXISTING OR PROPOSED NEW | | | SMOKE BARRIER WALLS REQUIRED BY SBC 409. | | | 1.2.INCLUDE THE EXISTING PORTION OF | | | THE BUILDING. DEMONSTRATE ALSO THE | | | REMAINING REQUIREMENTS OF SBC 409. | | | | | | THE MAINTENANCE AND STORAGE ROOMS IN THE | | | VICINITY OF GRID LINES F,3 ARE REQUIRED | | | TO HAVE FIRE RATED SEPARATION FROM THE | | | BUILDING BY SBC 409.1.5. | | | | | | SHEET S1 CITES ASCE 7-98.THE CITY IS | | | CURRENTLY USING THE 1997 SBC WHICH | | | INVOKES ASCE 7-95.FURTHER THE | | | OCCUPANCY CLASSIFICATION OF THIS | | | BUILDING IS A CATGORY III AND AN | | | IMPORTANCE FACTOR OF 1.15 NOT THE 1.0 | | | DECLARED. | | | | | | SHEET S10, "CABLE SIZE AND SPACING PER | | | LOCAL BUILDING CODE REQUIREMENTS" IS | | | NOT AN ACCEPTABLE SUBSTITUTE FOR | | | SPECIFIC DESIGN INFORMATION.SEE SBC | | | 104.2. | | | | | | SHEET S1, CITE THE SPECIFIC DESIGN | | | STANDARDS AND EDITIONS USED.SEE SBC | | | 3502 | | | | | | SHOW HOW THE ONE HOUR FIRE RATED | | | ASSEMBLY FOR THE ROOF WILL BE | | | ACCOMPLISHED.SEE SBC TABLE 600. | | | | | | AT TIME OF PERMIT APPLICATION PROVIDE | | | TEST REPORTS AND/OR PRODUCT NOTICE OF | | | ACCEPTANCE REPORTS FOR THE DOORS, | | | WINDOWS AND ROOF COVERING. | | | | | | SPECIFICATIONS 08800 CALL OUT A BROWARD | | | COUNTY PRODUCT APPROVAL.THE CITY | | | REQUIRES METRO-DADE OR TESTING FROM A | | | NATIONAL EVALUATION SERVICE CERTIFYING | | | COMPLIANCE WITH SSTD 12-97. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2002-05-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-01 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-01 |
Time |
18:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-08 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-08 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2002-02-08 00:00:00 | ********************** UNSAT *********** | | | | | | 1)NOTE: PLEASE NOET THAT LETTER OF | | | METHOD PROPOSED OF SHUTTING DOWN EM | | | MAIN WAS DECLINED BY FIRE AND THE BLDG | | | OFFICIAL. | | | CHIEF ELECTRICAL INSPECTOR AND ELEC. | | | PLAN REVIEW HAS ALSO DECLINED OPT METHOD | | | | | | | | | PLEASE SUBMIT REVISED RISER DIAGRAM AND | | | SERVICE LOCATION FOR REVIEW. IF THERE | | | ARE ANY QUESTIONS, PLEASE CALL., | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2002-02-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-05 |
Time |
06:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-05 |
Time |
06:40 |
Sent To |
|
|
| Notes |
| 2002-02-05 00:00:00 | ***************** UNSAT *************** | | | | | | PLEASE NOTE THAT PLANS ARE BACK IN FOR | | | REVIEW. AS PER CONVERSATIONS ON PHONE | | | WITH ENGINEER ALL MAINS WERE SAID TO BE | | | GROUPED AND THE ONLY ISSUE WAS TO | | | CLARIFY DOORS IN MAIN ELECTRICAL ROOM. | | | | | | 1)NOTE: PLEASE NOTE "MAIN" FOR EMDP IS | | | SHOWN BEING IN GENERATOR ROOM. PLEASE | | | NOTE THE MAIN COMING FROM NORMAL FPL | | | POWER IS LOCATED IN MAIN ELEC ROOM. THIS | | | IS FINE, BUT WHEN SYSTEM LOSES NORMAL | | | POWER AND GENERATOR KICKS IN, THE POWER | | | FROM GEN GOES DIRECTLY TO EMDP AND | | | THROUGHOUT EM PANELS. PLEASE NOTE, MAINS | | | ARE STILL NOTE GROUPED PER 230-72. | | | ALL EM PANELS WOULD BE "HOT" EVEN AFTER | | | SHUTTING DOWN MAINS. | | | WHATEVER HAPPENED TO SERVICE COMING INTO | | | NEW ELECTRICAL/GENERATOR ROOM AND THEN | | | FEEDING EXISTING BLDG? | | | PLEASE NOTE 230-76/230-79 | | | PLEASE ALSO NOTE "EMDO " IS SHOWN AS | | | "MLO"? PLEASE NOTE THAT MAIN ON GEN. | | | MUST BE ON OUTSIDE OF UNIT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2001-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-31 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-31 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2001-12-31 00:00:00 | ****************** UNSAT ************ | | | | | | 1)NOTE: PLEASE NOTE, PLANS ARE NOW | | | MOVING TWO OF THE THREE MAINS BACK TO | | | ORIG ELECTRICAL ROOM? PLEASE CLARIFY | | | HOW THE MAINS ARE NOW GROUPED PER 230-72 | | | ?? | | | PLEASE NOTE THAT THIS WAS AN ISSUE | | | BEFORE AND PLANS WERE CORRECTED, WHY | | | IS THIS BEING CHANGED BACK TO THE SAME | | | COMMENTS AS BEFORE? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRIAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-30 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-30 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2001-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-07 |
Time |
19:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-07 |
Time |
19:05 |
Sent To |
|
|
| Notes |
| 2001-11-07 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE AS PER LAST | | | CONVERSATION, EITHER SERVICE WAS GOING | | | TO BE GROUPED AND CIRCUITS BE ZONED SO | | | NOT TO CROSS EXISTING WITH NEW, OR | | | A NEW SERVICE LARGE ENOUGH TO BACK FEED | | | EXISTING? | | | PLEASE NOTE: 230-2 /230-72 | | | | | | 2)NOTE: PLEASE NOTE THAT SHUNT TRIPS | | | ARE NOT RATED FOR PURPOSE SHOWN. NEEDS | | | TO MEET 230-76 AND 230-79. | | | | | | | | | PLEASE CALL TO SET UP A MEETING TO GO | | | OVER ELECTRICAL SERVICE AND REQ`MENTS | | | FOR PROJECT. PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | | | | JAKE LEAHY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-659-8096 EXT 8451 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-10-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-09 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-01 |
Time |
21:31 |
Sent To |
|
|
| Notes |
| 2001-10-09 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SHOW HOW NEW SERVICE | | | CIRCUITS ARE GOING TO BE"ZONED" FROM | | | EXISTING CIRCUITS? RISER SHOWS NEW | | | SERVICE FEEDING EXISTING PANELS IN THE | | | EXISTING BLDG. | | | IS IS NOTED ON THIS PLAN REVIEW, THAT | | | THE NEW AND OLD SERVICE IS NOT GROUPED, | | | THIS WILL BE ALLOWED DUE TO THE SIZE OF | | | THE EXISTING SERVICE AND BLDG AS LONG | | | AS SERVICES ARE LABELED WITH THE | | | PLAGUESTHAT ARE NOTED ON PLANS. | | | PLEASE SHOW HOW NEW AND OLD CIRCUITS | | | AREGOING TO BE SEPARATED. | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | THIS WAS SUBMITTED TO THE CHIEF | | | ELECTRICAL INSPECTOR FOR REVIEW AND | | | "ZONING" | | | CLARIFICATIONS NEEDS TO BE SUBMITTED. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | JAKE LEAHY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-659-8096 EXT 8451 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-28 |
Time |
19:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-28 |
Time |
19:58 |
Sent To |
|
|
| Notes |
| 2001-08-28 00:00:00 | **************** UNSAT *************** | | | | | | PLEASE NOTE THAT ELECTRICAL PLANS ARE IN | | | VERY GOOD SHAPE. | | | PLEASE PLACE NOTE ON SHEET E-3 AND E-12 | | | FOR IDENTIFICATION OF MAINS ON DOORS | | | ON OUTSIDE OF GENERATOR ROOM AND MAIN | | | ELECTRICAL ROOM. PER 230-2E | | | | | | PLEASE NOTE THAT PLANS WOULD HAVE BEEN | | | REDLINED BUT WERE COMING BACK FOR OTHER | | | COMMENTS AND WERE ONLY IN FOR PLAN | | | REVIEW. | | | PLEASE PLACE NOTE ON PLANS AND SUBMIT | | | FOR FINAL REVIEW. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-09-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-09-21 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2001-09-21 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-01-16 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-01-16 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2003-01-16 00:00:00 | 1) PLANS ARE NOT STAMPED AND SEALED. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT. 8497 | | | 8352910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2002-05-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-14 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-14 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-11-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-29 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-29 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2001-10-29 00:00:00 | 1) NO FIRE SPRINKLER OR HYDRAULIC | | | CALCULATIONS PROVIDED WITH PLANS. | | | 2) PROVIDE MORE DETAILS ON 2000 | | | GALLON ABOVEGROUND FUEL TANKS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-09-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-25 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-25 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2001-09-25 00:00:00 | 1) NO FIRE SPRINKLER OR HYDRAULIC | | | CALCULATIONS PROVIDED WITH PLANS. THESE | | | ARE REQUIRED AT TIME OF PERMIT. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-27 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-27 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2001-08-27 00:00:00 | 1) HOW IS FIRE ACCESS PROPOSED TO THE | | | RESIDENCE ROOMS AND FUTURE TWO-STORY | | | FUTURE EXPANSION. | | | 2) FIRE PROTECTION NOTE ON LS-1 | | | INDICATES ROOM 161 WILL BE PROTECTED | | | BY AN FM 200 SYSTEM. FM 200 SYSTEM | | | CANNOT BE USED IN LIEU OF FIRE | | | SPRINKLERS. | | | 3) TABLE AND CHAIRS LOCATED DIRECTLY | | | IN FRONT OF SINGLE EXIT DOORS IN STAFF | | | DINING 2151. | | | 4) PLEASE EXPLAIN ROLL-DOWN NOTE ON | | | PAGE LS-1, PATIENT RECEPTION 464, NEAR | | | EXIT DOOR. | | | 5) PLEASE EXPLAIN FUTURE THERMAL STORAGE | | | AREA, ON PAGE LS-1, WHAT IS THIS USED | | | FOR. | | | 6) PLEASE PROVIDE MORE DETAILS ON | | | EMERGENCY GENERATOR. IF EMERGENCY | | | GENERATOR IS DIESEL FUEL SUPPLIED, IT | | | MUST BE AT LEAST AT LEAST TWO-HOUR | | | RATED. | | | 7) AUTOMOBILE PARKING GARAGE SHALL BE | | | SEPARATED BY AT LEAST A TWO HOUR FIRE | | | RATING NOT A ONE HOUR AS NOTED IN THE | | | FIRE RESISTANCE SEPARATION NOTES ON | | | PAGE LS-1. | | | 8) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY NEW HOOD,DUCT,AND SUPPRESSION | | | SYSTEMS PLANNED FOR KITCHEN 700. | | | 9) DEMOLITION ACTIVITIES PLANNED SHALL | | | NOT INTERFERE WITH ANY EXIT ACCESS, | | | EXITING, OR EXIT DISCHARGE. | | | 10) IS THE EXISTING LIQUID OXYGEN TANK | | | EXISTING OR NEW. HOW DOES THIS TANK | | | AND APPURTENANT EQUIPMENT INTERFERE | | | WITH ANY EXITING FROM THE CORRIDOR. | | | 11) PLEASE INDICATE EXIT CAPACITY FOR | | | STAIR 159. THIS STAIR APPEARS TO | | | PROVIDE EXITING FOR THE GARAGE AND | | | BUILDING. | | | 12) CANVAS CANOPIES TO BE FIRE | | | RETARDANT. | | | 13) FOLDING PARTITION WHEN USED IN STAFF | | | DINING 138 LIMITS ACCESS TO EXIT DOOR | | | 138A. | | | 14) PLEASE INDICATE OCCUPANT LOADS FOR | | | TRAINING ROOM 200 AND 200A. | | | 15) NO EXIT SIGNS DISPLAYED IN TRAINING | | | ROOM 200 AND 200A. | | | 16) SINGLE MEANS OF EGRESS PROVIDED FROM | | | CLERICAL 214. PLEASE EXPLAIN. | | | 17) FULL OXYGEN CYLINDERS SHOULD NOT | | | BE STORED WITH EMPTY OXYGEN CYLINDERS | | | IN 02 STORAGE G101. WHAT SAFETY | | | PRECAUTIONS ARE PLANNED FOR 02 ROOM | | | G101. | | | 18) NO FIRE SPRINKLER OR HYDRAULIC | | | CALCULATIONS PROVIDED WITH PLANS. | | | 19) PLEASE INDICATE ON PLANS THAT | | | GARAGE IS CONSIDERED OPEN AND DOCUMENT | | | PERCENTAGE OF OPENINGS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-30 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-28 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2003-01-30 00:00:00 | COMM. BOARD# 20./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-12-23 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2002-12-23 00:00:00 | TO COMM BOARD. #44 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-19 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-18 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2002-12-19 00:00:00 | COM BOARD # |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2003-02-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-08 |
Time |
07:46 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-02-08 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2003-02-08 00:00:00 | MECHANICAL PERMIT 01100489 - AS BUILT | | | DRAWINGS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
N |
Date |
2003-01-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-01-06 |
Time |
15:46 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-01-06 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2003-01-06 00:00:00 | AS BUILT DRAWINGS ARE NOT STAMPED & | | | SEALED BY ENGINEER OF RECORD. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2002-04-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-25 |
Time |
15:23 |
Rev Time |
1.30 |
| Received By |
pkrauss |
Date |
2002-04-25 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2002-04-25 00:00:00 | ADDED HEAT EXCHANGER, GLYCOL SYSTEM |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-01-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-04 |
Time |
09:11 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-01-04 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2002-01-04 00:00:00 | MECH REV PERMIT 01100489 - RUNNING CHWS | | | & R PIPING UNDERGROUND. | | | | | | UNDERGROUND PIPING SHALL HAVE A PRESSURE | | | TEST PRIOR TO COVERING. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-11-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-28 |
Time |
12:33 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2001-11-28 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2001-11-28 00:00:00 | | | | | | | SEE FIRE DEPT COMMENTS ON FUEL TANK. | | | | | | PLEASE SUBMIT DETAILS | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-10-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-12 |
Time |
13:03 |
Rev Time |
3.00 |
| Received By |
pkrauss |
Date |
2001-10-08 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2001-10-12 00:00:00 | *******************DENIED*************** | | | | | | 1.FIRE DAMPERS REQUIRED FOR ROOM 186, | | | PENETRATION THRU 3 HR WALL.ALSO | | | ON PLAN SHEET M-5, ROOMS 241 AND | | | 237 REQUIRE FIRE DAMPERS. | | | | | | 2.SMOKE DAMPERS REQUIRED FOR DUCTS | | | PENETRATING SMOKE WALLS IN THE | | | RESIDENTIAL AREAS (PLAN SHEET M-3). | | | 1997 SMC 610.3.1. | | | | | | 3.AUXILIARY DRAIN PANS REQUIRED WITH | | | OVERFLOW PROTECTION FOR FAN COIL | | | UNITS.1997 SMC 304.8.6.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-08-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-27 |
Time |
09:12 |
Rev Time |
4.00 |
| Received By |
pkrauss |
Date |
2001-08-24 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2001-08-27 00:00:00 | *******************DENIED*************** | | | | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW. | | | | | | 1.PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS AS PER ASHRAE 62-89. | | | | | | 2.PROVIDE AIR BALANCE SCHEDULE TO | | | SHOW COMPLIANCE WITH 1997 SMC 501.2 | | | | | | 3.FIRE DAMPERS NOT INDICATED ON PLAN | | | FOR THE FOLLOWING ROOMS - 111, 126, | | | 168. | | | | | | 4.INDICATE MAKE-UP AIR FOR GAS FIRED | | | WATER HEATERS. | | | | | | | | | NOTE:EXHAUST DUCTS CONVEYING NOXIOUS | | | GASES, FLAMMABLE/CORROSIVE VAPORS | | | AND DUCTS SERVING COMMERCIAL FOOD | | | COOKING AND PROCESSING EQUIPMENT | | | SHALL TERMINATE OUTSIDE OF THE | | | BUILDING AND LOCATED 10' FROM ANY | | | ADJACENT BUILDING, PARKING AREA, | | | ADJACENT PROPERTY LINE, WINDOW, | | | DOOR OR AIR INTAKE AND AT LEAST | | | 10' ABOVE THE ADJOINING GRADE | | | LEVEL.EXHAUST OUTLET WHICH IS | | | LOCATED ABOVE THE ROOF SHALL | | | TERMINATE AT LEAST 40" ABOVE THE | | | ROOF SURFACE. | | | | | | ADDITIONAL PLANS AND PERMITS REQUIRED | | | FOR HOOD, FIRE SUPRESSION, AND WALK-IN | | | COOLERS.PLEASE PROVIDE MANUFACTURER | | | SUBMITTAL DATA WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
P |
Date |
2003-02-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-05 |
Time |
17:08 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-02-05 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2003-02-05 00:00:00 | AS BUILTS 0K |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
F |
Date |
2003-01-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-14 |
Time |
10:55 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-01-14 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2003-01-14 00:00:00 | DENIED | | | | | | AS-BUILTS SHALL BE SIGNED AND SEALED BY | | | ENGINEER OF RECORD. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2002-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-20 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-20 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2002-07-20 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SHT P-4 GAS RISER DIAGRAM, MANUAL | | | SHUT OFF VALVE SHALL BE NEXT TO UNION | | | AND AUTOMATIC SHUT OFF VALVE NOT APPROX. | | | 15' AS SHOWN. | | | | | | 2) SHT SHT P-11 PLEASE SHOW TYPE OF PIPE | | | INSTALLED UNDERGROUND. | | | | | | 3) SHT P-11 SHOWS 3" SCHED 40 PIPE SUPP- | | | LYING 1,670,000 @ 520 FEET. MAX IS | | | 1,514,000 BTU,S. MINIMUM 4" PIPE SHALL | | | RUN FROM METER TO EXISTING GAS LINE FOR | | | EXISTING HEATER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2002-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-20 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-19 |
Time |
20:25 |
Sent To |
|
|
| Notes |
| 2002-07-20 00:00:00 | SEE NEXT REVIEW. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2002-05-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-11 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-11 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2002-05-11 00:00:00 | REVISION OK - SECONDARY ROOF DRAINS, | | | MOVE RWL - MOVE BULK OXYGEN, ADD DROPS | | | FOR OXYGEN - AIR IN PATIENT ROOMS - |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2001-12-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-07 |
Time |
14:42 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-07 00:00:00 | PROVISO MEDICAL GAS COMPLY W/ 99-C,CH-4 | | | LEVEL-I, FOR OXYGEN,VACUM.PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-14 |
Time |
12:41 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-11-14 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-03 |
Time |
11:39 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2001-11-03 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2001-11-03 00:00:00 | DENIED | | | REFERENCE: SPC-94 - SGC-97 - FABCB-97 | | | 1) PERMIT WILL NOT BE ISSUED UNTIL THE | | | LETTER FROM PALM BEACH COUNTY HEALTH | | | UNIT DIVISION OF ENVIRONMENTAL HEALTH IS | | | RECIEVED FOR PLAN REVIEW AS REQUESTED. | | | 2) PAGE P-7 WATER RISER DIAGRAM. WATER | | | HAMMER ARRESTORS IN KITCHEN AREA AND IN | | | PUBLIC RESTROOMS (HOT) ARE REQUIRED TO | | | BE CLOSE TO FIXTURES NOT AT TOP OF DROP | | | AS SHOWN. PLEASE COMPLY | | | 3) PAGE P-10 HUMIDIFIER DETAIL. FLOOR | | | DRAIN TO BE CHANGED TO FLOOR SINK AS RE- | | | QUESTED IN PREVIOUS COMMENTS. | | | 4) LETTER FROM RODNEY COMPO STILL NOT | | | RECIEVED. LETTER REQUIRED FOR SIZING & | | | LOCATING GREASE TRAP. | | | 5) PAGE A-11 HDCP SHOWER DETAIL. NEW DE- | | | TAIL ADD IN FOR 60" SHOWER. HDCP SHOWERS | | | SHOWN ARE NOT 60" SHOWERS AND SHALL COM- | | | PLY WITH FIGURE 35(A) FACBC-97. PLEASE | | | SHOW COMPLIANCE WITH SEC 4.21. | | | 6) PLEASE SUBMIT CALCULATION FOR CONFIN- | | | ED SPACE FOR WATER HEATERS. RESPONSE | | | SHOWS VENTING BY NOT CALCULATIONS FOR | | | COMBUSTION AIR. LOUVERS SHOWN ON PAGE | | | A-5 ARE NOT A LARGE ENOUGH AREA FOR | | | EITHER ROOM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-10-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-09 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2001-10-09 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2001-10-09 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 - SGC-97 | | | | | | NOTE: LETTER FROM PALM BEACH COUNTY | | | HEALTH UNIT DIVISION OF ENVIRONMENTAL | | | REQUIRED FOR PERMIT PLAN REVIEW. | | | | | | 1) PLEASE PROVIDE A WATER RISER DIAGRAM | | | FOR PLAN REVIEW. SHOW SIZE AND LOCATION | | | OF WATER HAMMER ARRESTORS PER MANUFACT- | | | URE INSTALLATION INSTRUCTION AND WH-PDI | | | 201. | | | 2) STORM RISER DIAGRAM STILL REQUIRED | | | FOR ROOF DRAINS AND SECONDARY DRAINS | | | FOR ROOF ABOVE KITCHEN AND ADJOINING NEW | | | ROOFS AND FOR ROOFS ABOVE NEW RESIDENT- | | | IAL AREAS. SUBMIT CALCULATIONS FOR ROOF | | | DRAINS AND SECONDARY DRAINS. SHOW ALL | | | PIPE SIZES. | | | 3) PAGE P-10 HUMIDIFIER DETAIL SHOWS THE | | | INDIRECT WASTE TO FLOOR DRAIN. FLOOR | | | SINK IS REQUIRED, PLEASE CHANGE DETAIL. | | | 4) LETTER FROM R. COMPO REQUIRED FOR | | | GREASE TRAP SIZING AND LOCATION. PLEASE | | | HAVE INFORMATION FOR PLAN REVIEW. (FROM | | | PREVIOUS REVIEW ITEM #6.) | | | 5) PAGE A-11 HDCP SHOWER DETAIL. PLEASE | | | SHOW ALL DETAILS REQUESTED ON PREVIOUS | | | PLAN REVIEW. SEAT, CURB TO BE 1/2" PER | | | FACBC-97. AND SEC 6 BACKING. | | | 6) MY PREVIOUS COMMENTS #12 NOT ADDRESS- | | | ED FOR DIRECT VENT FOR WATER HEATER. | | | PLEASE PROVIDE DETAILS. | | | 7) ALL CONDENSATE TO DRAIN SEPARATE FROM | | | BLDG. PLEASE PROVIDE CONDENSATE RISER | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-28 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2001-08-25 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2001-08-28 00:00:00 | DENIED | | | REFERENCES SPC-94/FACBC-97 | | | | | | NOTE: ROUTE PLANS TO PALM BEACH COUNTY | | | HEALTH UNIT DIVISION OF ENVIRONMENTAL | | | HEALTH, 901 EVERNIA STREET WPB FL 33401 | | | (561) 355-3018, BEFORE CITY OF WPB PLAN | | | REVIEW. | | | | | | 1) PLEASE PROVIDE A WATER RISER DIAGRAM | | | FOR PLAN REVIEW. FOR SIZE AND PLACEMENT | | | OF WATER HAMMER ARRESTORS, PLEASE SEE | | | MANUFACTURES INSTALLATION INSTRUCTION & | | | PDI WH 201. PAGES P-3, P-4, AND P-5. | | | | | | 2) PAGES P-2 & P-7, W/C'S NOT VENTED | | | PROPERLY ON MAIN BLDG DRAIN. W/C'S SHALL | | | BE WET VENTED PER SPC-94, SECT. 911. | | | | | | 3) PAGES P-2 & P-7, W/C'S NOT VENTED | | | PROPERLY. PER SPC-94 SECT. 914, RELIEF | | | VENT CONNECTED IN FRONT OF THE FIRST | | | FIXTURE CONNECTION. | | | | | | 4) STORM RISER DIAGRAM REQUIRED. SUBMIT | | | CALCULATIONS FOR ROOF DRAINS AND SECOND- | | | ARY DRAINS/SCUPPERS PER SPC-94 SECT.1108 | | | AND 1109. PAGES P-6, P-8, AND P-9. | | | | | | 5) PAGE P-4, BACKFLOW REQUIRED FOR 1/2" | | | CW HOOKUP TO HUMIDIFIER AT A/C IN ROOM | | | 161. SUBMIT DETAIL FOR BACKFLOW AND | | | FLOOR SINK TO DRAIN INTO. SPC-94 SECT. | | | 606.1& SECT. 807 | | | | | | 6) GREASE TRAP TO BE LOCATED AND SIZED | | | BY UTILITY DEPT. PLEASE CONTACT RODNEY | | | COMPO AT (561) 837-4074 FOR APPROVED | | | GREASE TRAP DETAIL SEE ATTACHED SHEET. | | | | | | 7) PAGES P-4 & P-5. ELECTRIC WATER COOL- | | | ERS SHALL COMPLY WITH FACBC-97 SECT. 415 | | | ALSO SECT. 4.1.3 (10) FOR PEOPLE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. | | | | | | 8) PAGE A-11, PLEASE SHOW DETAILS THAT | | | BATHROOMS IN PATIENTS RESIDENTAL ROOMS | | | COMPLY WITH FACBC-97. SECT. 6, (2). NO | | | CURB ON SHOWER, SEAT & GRAB BARS IN | | | SHOWER. | | | | | | 9) SEPARATE PERMIT REQUIRED FOR GAS. | | | SEE ATTACHED SHEET FOR GAS PERMIT APPLI- | | | CATION REQUIREMENTS. ALL INFORMATION | | | TO BE SUBMITTED WITH APPLICATION. | | | PAGES P-4 & P-10 | | | | | | 10) SEPARATE PERMIT REQUIRED FOR MED-GAS | | | PLEASE PROVIDE CONTRACTOR CERTIFICATION, | | | BRAZER CERTIFICATION PER NFC99 SECT. | | | 4-3.1.2.12, AND 4-3.1.2.10. CHAPTER 17 | | | SECT. 17.3.4, SPECIFY A LEVEL FOR PIPING | | | REQUIREMENTS, SOURCE EQUIPMENT, AND | | | ALARM REQUIREMENTS. PER 99 NFC REF. CHAP | | | TER 13. PAGES MP-1 AND MP-2. | | | | | | 11) PLEASE SUBMIT A VACUUM SYSTEM DETAIL | | | FOR PLAN REVIEW. SUBMIT MANUFACTURE'S | | | INFORMATION ON PUMPS. MP-1 & MP-2. | | | | | | 12) PLEASE SUBMIT DETAILS ON DIRECT VENT | | | FOR WATER HEATER. N-36 VACUUM BREAKER | | | REQUIRED ON BOTTOM FEED WATER HEATER, | | | PLEASE SHOW DETAIL. 507.1.2 SPC-94 | | | PAGE P-10 W/HEATER DETAIL NOTE 15-2, | | | 110 DEGREE TO HAND SINKS ALSO. PAGE P-3 | | | | | | 13) PAGE FS-1 #16, VAC. BREAKER INSTALL- | | | ED 6" ABOVE FLOOD RIM LEVEL. | | | | | | 14) PAGE FS-1 #65 DISHWASHER TO SANITARY | | | PER UTILITY DEPT. ALSO #'S 16 & 64, GAR- | | | BAGE DISPOSALS TO DISCHARGE INTO SANIT- | | | ARY, DIRECT HOOK UP. | | | | | | 15) PAGE P-7, KITCHEN RISER DIAGRAM. DIA | | | GRAM SHOWS RISER AS "SS", SHOULD BE "GW" | | | ALSO GREASE WASTE AND SANITARY LINES CAN | | | NOT TIE TOGETHER AS SHOWN AT NOTE 15-2 | | | | | | 16) PAGE FS-3, PLUMBING CONNECTION SCHED | | | P-2 FUNNEL FLOOR DRAINS NOT APPROVED, | | | PLEASE PROVIDE FLOOR SINKS. SPC-94 804.1 | | | AND SECT. 807. | | | | | | 17) PAGE FS-3, PLUMBING CONN. SCHED. | | | P-24 THRU P-29 SHALL COMPLY WITH GAS | | | PERMIT APPLICATION REQUIREMENTS ( SEE | | | ATTACHED). | | | | | | 18) PAGE FS-3, PLUMB. CONN. SCHED. P-40 | | | AND P-42, SUBMIT BACKFLOW INFORMATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-10-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-04-30 |
Time |
07:36 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|