| Plan Review Stops For Permit 01080248 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-08-30 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-08-30 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2001-08-30 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-07 |
Time |
19:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-07 |
Time |
19:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-18 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-18 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | ********** UNSAT ****** | | | | | | 1)NOTE: PLEASE NOTE THAT FIRE REVIEW | | | STILL HAS COMMENTS TO BE ADDRESSED. | | | PLEASE NOTE THAT 2X4 LAY IN FIXTURES | | | SHOWN AS "NL" NIGHT LIGHTS, ARE THESE | | | EM LTS ? PLEASE CLARIFY. | | | | | | | | | PLEASE ADDRESS ANY FIRE COMMENTS AND | | | SUBMIT CLARIFICATION ON "NL"? ARE THEY | | | "EM"? | | | PLEASE SUBMIT FOR REVIEW. IF THERE ARE | | | ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-21 |
Time |
20:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-21 |
Time |
20:18 |
Sent To |
|
|
| Notes |
| 2001-08-21 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE PROVIDE CLARIFICATION | | | FOR EM LTS AND EXIT LTS. PLEASE NOTE | | | THAT DUE TO COMMENTS FORM FIRE PLAN | | | REVIEW. PLANS WILL HAVE CHANGES DONE TO | | | THE ELECTRICAL SHEETS. PLEASE ADDRESS | | | ABOVE AND FIRE REVIEW. | | | ELECTRICAL PLANS ARE IN GOOD SHAPE | | | OTHER THAN THE ABOVE CLARIFICATION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVOEW. IF THERE AREANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELELCTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-08-27 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-08-27 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-11-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-19 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-19 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-18 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-18 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | 1) SECURITY FEATURES PLANNED FOR EXIT | | | DOOR IS TO BE FURTHER EXPLAINED. LOCKS | | | ELECTRIC OR MAGNETIC MUST COMPLY WITH | | | SPECIAL LOCKING ARRANGEMENTS. LOCKS | | | ON EXIT DOORS MUST BE FAIL SAFE AND NOT | | | FAIL SECURE. PLEASE EXPLAIN. | | | 2) NIGHT-LIGHTS ARE SHOWN AS EMERGENCY | | | LIGHTING. NIGHT-LIGHTS ARE ACTIVATED | | | HOW AND ARE THEY ON A TIMER. WHAT | | | HAPPENS WHEN LOSS OF POWER OCCURS. | | | PLEASE CORRECT EMERGENCY LIGHTING ISSUE | | | UP. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-07 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-07 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2001-08-07 00:00:00 | 1) DUST CONTROL METHODS SHALL NOT | | | INCLUDE THE HANGING OF NON FIRE | | | RATED VISQUEEN. | | | 2) PLEASE INDICATE LOCATIONS OF | | | EXISTING FIRE ALARM EQUIPMENT. | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR NEW HOOD, DUCT AND EXTINGUISHING | | | SYSTEM. | | | 4) GLASS AUTOMATIC DOORS TO COMPLY | | | WITH POWERED OPERATED DOORS, PLEASE | | | SEE NFPA 101, THE LIFE SAFETY CODE, | | | 1985 EDITION, SECTION 5-2.1.9. | | | 5) PLEASE INDICATE LOCATION OF | | | CHAIN LINK FENCE. | | | 6) PLEASE CLEARLY INDICATE ILLUMINATED | | | EXIT SIGNS AND EMERGENCY LIGHTS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-09-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-26 |
Time |
10:22 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-09-26 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2001-09-26 00:00:00 | ******************PROVISO*************** | | | | | | REVIEW COMMENTS THE SAME AS 8-24-01. | | | | | | PRIOR TO CONNECTING TO ANY EXISTING | | | DUCTWORK, CALL FOR AN INSPECTION. | | | | | | ADDITIONAL PERMITS REQUIRED FOR HOOD, | | | FIRE SUPRESSION AND WALK-IN | | | COOLER/FREEZER.PLEASE SUBMIT PLANS | | | AND MANUFACTURER SUBMITTAL DATA WITH | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS 659-8096 EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-08-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-24 |
Time |
10:34 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2001-08-24 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2001-08-24 00:00:00 | *******************PROVISO************** | | | | | | | | | PRIOR TO CONNECTING TO ANY EXISTING DUCT | | | WORK, CALL FOR AN INSPECTION. | | | | | | | | | ADDITIONAL PLANS AND PERMITS REQUIRED | | | FOR HOOD, FIRE SUPRESSION AND WALK-IN | | | COOLER.PLEASE SUBMIT MANUFACTURER | | | SUBMITTAL DATA AND PLANS WITH PERMIT | | | APPLICATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-08-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-25 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2001-08-25 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-08-27 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-08-27 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|