Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-10-28 Cont ID  
Sent By dpalmer Date 2003-10-28 Time 10:54 Rev Time 0.50
Received By dpalmer Date 2003-10-28 Time 10:54 Sent To  
Notes
2003-10-28 00:00:00REDLINED PLANS.
 TO BE FIELD VERIFIED.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2003-08-08 Cont ID  
Sent By csiegber Date 2003-10-27 Time 14:28 Rev Time 1.00
Received By dpalmer Date 2003-08-07 Time 16:45 Sent To  
Notes
2003-08-08 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE SEE THAT REDLINES FROM
 ORIG REVIEW TWO YEARS AGO HAVE NOT BEEN
 CHANGED. PLEASE SEE GROUNDING ELECTRODE
 SYSTEM STILL REF'S 96 NEC. THIS WAS
 PERMITTED UNDER THE 99 NEC. PLEASE
 CHANGE ALLNEC CODE ARTS ACCORD.
  
 2)NOTE: PLEASE SEE 220 FOR MIN KW FOR
 RANGE. PLEASE ADJUST LOAD CALCULATIONS.
  
 3)NOTE: PLEASE SEE MISSING RECEPTS PER
 210-52. SEEMS TO HAVE AN OLD DOORWAY
 CLOSED UP WHICH BRINGS ON NEXT COMMENT
 FOR BDEROOM #4.
  
 4)NOTE: PLEASE SEE MISSING SD REQ'D
 OUTSIDE BEDRM #4
  
 5)NOTE: PLEASE SEE 210-52C, 1,2,3,4,5
 FOR KITCHEN COUNTER RECEPTS. PLEASE
 SEE PENINSULAR AND SEPARATE SPACES.
  
 6)NOTE: PLEASE SEE 210-8 FOR ALL REQ'D
 GFI/GFI PROTECTED RECEPTS. GARAGE/ OUT-
 -SIDE ETC.
  
 7)NOTE: PLEASE SEE 210-70 FOR CONTROL
 OF EGRESS LIGHTING TO BCAK PORCH AREA.
 PLEASE SHOW HOW AND WHERE LTS ARE
 TURNED ON AND OFF???
  
 8)NOTE: PLEASE SEE RISER DIAGRAM,
 SHOWS PANEL AS BEING A 8/16 CIRCUIT
 PANEL AND YET PANEL SCHEDULE SHOWS A
 44-45 CIRCUIT PANEL?? PLEASE NOTE, PANEL
 DO NOT AND ARE NOT MADE W/ MORE THAN
 42 CIRCUITS? 384-15
 PLEASE SHOW REVISED RISER DIAGRAM AND
 PLEASE SHOW LOCATION OF SERVICE AND
 METER ON PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REIVEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-07-14 Cont ID  
Sent By alange Date 2003-08-04 Time 13:07 Rev Time 0.50
Received By dpalmer Date 2003-07-14 Time 11:48 Sent To  
Notes
2003-07-14 00:00:00************** UNSAT ****************
  
 1)NOTE; PLANS MUST RE-DONE BY THE
 ENGINEER OF RECORD. PLANS ALSO MUST BE
 SIGNED DATED AND SEALED BY ENG.
 PER FS 471.025.
  
 2)NOTE: PLEASE HAVE CORRECTIONS DONE
 AS ORIG REDLINED IN OCT 2001
  
 PLEASE SUBMIT THE ABOVE INFOMATION FOR
 REVIEW. IF THERE ARE NAY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-09 Cont ID  
Sent By shernand Date 2003-07-01 Time 16:03 Rev Time 0.00
Received By dpalmer Date 2001-10-09 Time 19:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-23 Cont ID  
Sent By dpalmer Date 2001-08-23 Time 10:23 Rev Time 0.00
Received By dpalmer Date 2001-08-23 Time 10:23 Sent To  
Notes
2001-08-23 00:00:00****************** UNSAT **************
  
 1) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 PLEASE NOTE SOME MISSING LOCATIONS.
  
 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
 SHOWN FOR PANEL BUT NOT FOR MAIN.
  
 5) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE.
  
 6) PLEASE CLARIFY EQUIPMENT GROUNDING
 METHOD BETWEEN FIRST MEANS OF DISCONNECT
 AND PANEL(S). EQUIPMENT GROUNDING
 CONDUCTORS ARE TO BE SIZED BY 250-122.
  
 7)NOTE:PLEASE SHOW GARAGE OUTLET AS
 GFI. PER 210-8
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE QUESTIONS, PLEASE
 CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-11-12 Cont ID  
Sent By csiegber Date 2003-11-12 Time 14:51 Rev Time 0.00
Received By csiegber Date 2003-11-12 Time 14:51 Sent To P
Notes
2003-11-12 00:00:00REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-10-27 Cont ID  
Sent By csiegber Date 2003-10-27 Time 14:28 Rev Time 0.00
Received By csiegber Date 2003-10-27 Time 14:28 Sent To E
Notes
2003-10-27 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-27 Cont ID  
Sent By csiegber Date 2003-10-27 Time 14:25 Rev Time 0.00
Received By csiegber Date 2003-10-27 Time 14:25 Sent To P
Notes
2003-10-27 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-04 Cont ID  
Sent By alange Date 2003-08-04 Time 13:07 Rev Time 0.00
Received By alange Date 2003-08-04 Time 13:07 Sent To E
Notes
2003-08-04 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-01 Cont ID  
Sent By shernand Date 2003-07-01 Time 16:03 Rev Time 0.00
Received By shernand Date 2003-07-01 Time 16:03 Sent To E
Notes
2003-07-01 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-01 Cont ID  
Sent By shernand Date 2003-07-01 Time 16:02 Rev Time 0.00
Received By shernand Date 2003-07-01 Time 16:02 Sent To B
Notes
2003-07-01 00:00:00STHYNG DESK, PRODUCT APPROVALS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-02-11 Time 11:56 Rev Time 0.00
Received By dpalmer Date 2003-02-11 Time 11:56 Sent To M
Notes
2003-02-11 00:00:00TO MECH INBOX.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-02-14 Cont ID  
Sent By pkrauss Date 2003-02-14 Time 16:04 Rev Time 0.30
Received By pkrauss Date 2003-02-14 Time 16:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-10-08 Cont ID  
Sent By dpalmer Date 2003-02-11 Time 11:56 Rev Time 0.35
Received By pkrauss Date 2001-10-08 Time 08:12 Sent To  
Notes
2001-10-08 00:00:00PROVISO ON PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-21 Cont ID  
Sent By hmoser Date 2001-08-21 Time 17:01 Rev Time 0.33
Received By hmoser Date 2001-08-21 Time 17:01 Sent To  
Notes
2001-08-21 00:00:00PLAN DENIED
 #1 10 IN. DUCT IS TO SMALL
 TO SUPPLY 1144 CFM OFF
 TRINGAL
  
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 5 Status P Date 2003-11-24 Cont ID  
Sent By jleech Date 2003-11-24 Time 17:00 Rev Time 0.50
Received By jleech Date 2003-11-24 Time 17:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-11-01 Cont ID  
Sent By csiegber Date 2003-11-12 Time 14:51 Rev Time 0.50
Received By kstevens Date 2003-11-01 Time 07:15 Sent To  
Notes
2003-11-01 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) NEW RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN. THE NEW SINK ON THE SANT
 RISER DIAGRAM SHALL BE SHOWN ON THE
 FLOOR PLAN. PLEASE SUBMIT A REVISION FOR
 THE FLOOR PLAN ALSO. SECTION 104.2.1
 2) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS, AND LICENSE NUMBER
 ON EACH SHEET. LICENSE NUMBER NOT SHOWN
 PLEASE SEE THIS HAS BEEN THE SAME
 COMMENT ON MANY PREVIOUS REVIEWS. WE ARE
 NOW RETAINING ONE SET OF PLANS TO BE
 FILED AND TURNED INTO THE FBPE FOR THIS
 VIOLATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-11-09 Cont ID  
Sent By csiegber Date 2003-10-27 Time 14:25 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-10-12 Cont ID  
Sent By kstevens Date 2001-10-12 Time 09:25 Rev Time 0.33
Received By kstevens Date 2001-10-12 Time 09:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-15 Cont ID  
Sent By kstevens Date 2001-08-15 Time 18:21 Rev Time 0.50
Received By kstevens Date 2001-08-15 Time 18:21 Sent To  
Notes
2001-08-15 00:00:00DENIED
  
 SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS OR REFLECT THE FLOOR
 PLAN.
 PLEASE SUBMIT A RISER DIAGRAM THAT RE-
 FLECTS THE FLOOR PLAN AND MEETS CODE
 REQUIREMENTS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-11-14 Cont ID  
Sent By lhatten Date 2001-11-14 Time 18:02 Rev Time 1.00
Received By lhatten Date 2001-11-14 Time 18:01 Sent To  
Notes
2001-11-14 00:00:00PLANS OK 11/14/2001 PER LOU HATTEN
 PLANS OK 11/14/2001 PER LOU HATTEN

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-10-26 Cont ID  
Sent By lhatten Date 2001-10-26 Time 15:30 Rev Time 1.00
Received By lhatten Date 2001-10-26 Time 15:28 Sent To  
Notes
2001-10-26 00:00:00MISSING WINDOW PRESSURES AND STILL
 SOME PRODUCT APPR. NOT UP TO DATE
 10/26/2001
 SAME AS ABOVE 10/26/2001

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-09-06 Cont ID  
Sent By lhatten Date 2001-09-06 Time 15:26 Rev Time 3.00
Received By lhatten Date 2001-09-06 Time 15:17 Sent To  
Notes
2001-10-26 00:00:00NEED UP TO DATE PRODUCT APPROVALS &
 WINDOW /DOOR PRESSURES
 OWNER TO PICK-UP TO FIX PLANS 09/06/2001
 OWNER TO PICK-UP AND FIX AND RETURN TO
 BUILDING DEPT. 09/06/2001

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-07 Cont ID  
Sent By sgraham Date 2001-08-07 Time 12:12 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***